Functional Alignment Philosophy in Total Knee Arthroplasty – Rationale and technique for the varus morphotype using a CT based robotic platform and individualized planning

IF 1.8 Q2 ORTHOPEDICS SICOT-J Pub Date : 2022-04-01 DOI:10.1051/sicotj/2022010
J. Shatrov, Cécile Battelier, E. Sappey-Marinier, S. Gunst, E. Servien, S. Lustig
{"title":"Functional Alignment Philosophy in Total Knee Arthroplasty – Rationale and technique for the varus morphotype using a CT based robotic platform and individualized planning","authors":"J. Shatrov, Cécile Battelier, E. Sappey-Marinier, S. Gunst, E. Servien, S. Lustig","doi":"10.1051/sicotj/2022010","DOIUrl":null,"url":null,"abstract":"Introduction: Alignment techniques in total knee arthroplasty (TKA) continue to evolve. Functional alignment (FA) is a novel technique that utilizes robotic tools to deliver TKA with the aim of respecting individual anatomical variations. The purpose of this paper is to describe the rationale and technique of FA in the varus morphotype with the use of a robotic platform. Rationale: FA reproduces constitutional knee anatomy within quantifiable target ranges. The principles are founded on a comprehensive assessment and understanding of individual anatomical variations with the aim of delivering personalized TKA. The principles are functional pre-operative planning, reconstitution of native coronal alignment, restoration of dynamic sagittal alignment within 5° of neutral, maintenance of joint-line-obliquity and height, implant sizing to match anatomy and a joint that is balanced in flexion and extension through manipulation of implant positioning rather than soft tissue releases. Technique: An individualized plan is created from pre-operative imaging. Next, a reproducible and quantifiable method of soft tissue laxity assessment is performed in extension and flexion that accounts for individual variation in soft tissue laxity. A dynamic virtual 3D model of the joint and implant position that can be manipulated in all three planes is modified to achieve target gap measurements while maintaining the joint line phenotype and a final limb position within a defined coronal and sagittal range. Conclusion: Functional alignment is a novel knee arthroplasty technique that aims to restore constitutional bony alignment and balance the laxity of the soft tissues by placing and sizing implants in a manner that it respects the variations in individual anatomy. This paper presents the approach for the varus morphotype.","PeriodicalId":46378,"journal":{"name":"SICOT-J","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICOT-J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/sicotj/2022010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 16

Abstract

Introduction: Alignment techniques in total knee arthroplasty (TKA) continue to evolve. Functional alignment (FA) is a novel technique that utilizes robotic tools to deliver TKA with the aim of respecting individual anatomical variations. The purpose of this paper is to describe the rationale and technique of FA in the varus morphotype with the use of a robotic platform. Rationale: FA reproduces constitutional knee anatomy within quantifiable target ranges. The principles are founded on a comprehensive assessment and understanding of individual anatomical variations with the aim of delivering personalized TKA. The principles are functional pre-operative planning, reconstitution of native coronal alignment, restoration of dynamic sagittal alignment within 5° of neutral, maintenance of joint-line-obliquity and height, implant sizing to match anatomy and a joint that is balanced in flexion and extension through manipulation of implant positioning rather than soft tissue releases. Technique: An individualized plan is created from pre-operative imaging. Next, a reproducible and quantifiable method of soft tissue laxity assessment is performed in extension and flexion that accounts for individual variation in soft tissue laxity. A dynamic virtual 3D model of the joint and implant position that can be manipulated in all three planes is modified to achieve target gap measurements while maintaining the joint line phenotype and a final limb position within a defined coronal and sagittal range. Conclusion: Functional alignment is a novel knee arthroplasty technique that aims to restore constitutional bony alignment and balance the laxity of the soft tissues by placing and sizing implants in a manner that it respects the variations in individual anatomy. This paper presents the approach for the varus morphotype.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全膝关节置换术中的功能对齐理念-利用基于CT的机器人平台和个性化计划进行内翻形态的原理和技术
导言:全膝关节置换术(TKA)中的对齐技术不断发展。功能对准(FA)是一种利用机器人工具提供TKA的新技术,其目的是尊重个体解剖变异。本文的目的是描述利用机器人平台对内翻形态进行FA的原理和技术。理由:FA在可量化的目标范围内再现了体质性膝关节解剖。这些原则是建立在对个体解剖变化的全面评估和理解的基础上的,目的是提供个性化的TKA。原则是功能性术前计划,重建天然冠状位,在中性5°范围内恢复动态矢状位,维持关节线斜度和高度,种植体尺寸匹配解剖结构,通过操纵种植体定位而不是软组织释放来平衡关节的屈伸。技术:根据术前影像制定个体化方案。接下来,一种可重复和可量化的软组织松弛评估方法在伸展和屈曲中进行,说明了软组织松弛的个体差异。关节和植入物位置的动态虚拟3D模型可以在所有三个平面上进行操作,以实现目标间隙测量,同时保持关节线表型和在定义的冠状和矢状范围内的最终肢体位置。结论:功能性对齐是一种新的膝关节置换术,其目的是通过尊重个体解剖结构差异的方式放置和大小植入物来恢复骨结构对齐和平衡软组织松弛。本文介绍了内翻型的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
SICOT-J
SICOT-J ORTHOPEDICS-
CiteScore
3.20
自引率
12.50%
发文量
44
审稿时长
14 weeks
期刊最新文献
Adapting hip arthroplasty practices during the COVID-19 pandemic: Assessing the impact of outpatient care sudden increase on early complications and clinical outcomes. Outcomes of total hip arthroplasty using dual mobility cups following failed internal fixation of proximal femoral fractures at a mean follow-up of 6 years. Prior medial meniscus arthroscopy is not associated with worst functional outcomes in patients undergoing primary total knee arthroplasty: A retrospective single-center study with a minimum follow-up of 5 years. Short-term functional outcomes of robotic-assisted TKA are better with functional alignment compared to adjusted mechanical alignment. Delayed presentation of lower cervical facet dislocations: What to learn from past reports?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1