Influence of fibers and hardening accelerator on the concrete for rigid pavements

IF 1.8 4区 工程技术 Q3 CONSTRUCTION & BUILDING TECHNOLOGY Magazine of Concrete Research Pub Date : 2023-03-13 DOI:10.1680/jmacr.22.00181
Ž. Kos, S. Kroviakov, V. Kryzhanovskyi, A. Crnoja
{"title":"Influence of fibers and hardening accelerator on the concrete for rigid pavements","authors":"Ž. Kos, S. Kroviakov, V. Kryzhanovskyi, A. Crnoja","doi":"10.1680/jmacr.22.00181","DOIUrl":null,"url":null,"abstract":"The influence of the hardening accelerator and steel fiber on the concrete adhesion strength for the repair of rigid highway and airfield pavements has been investigated. The concretes were mixed based on the CEM II/A-S 42.5 and included MasterGlenium SKY 608 superplasticizer. Experiment with two variable concrete composition factors was carried out. The amount of steel fiber varied from 0 to 100 kg/m3, the amount of Sika Rapid hardening accelerator varied from 0 to 9.6 kg/m3. It was found that modified repair concretes have a sufficiently high adhesion strength to \"old\" concrete, from 2.30 MPa when tested by the pull-off method and from 2.05 MPa when tested by the flexural strength test method. Fiber-reinforcement increases the adhesion strength of repair concrete by 7-15% due to reducing of shrinkage during hardening. Treating the contact surface of \"old\" concrete with a primer additionally increases adhesion strength by 6-10%. The maximum adhesion strength of fiber-reinforced concrete to the base reaches 3 MPa. Due to the high early and design strength, modified steel fiber-reinforced concrete provides the possibility of quick resumption of traffic while ensuring the integrity of the road structure due to the joint work of the repair material with the old concrete repair area.","PeriodicalId":18113,"journal":{"name":"Magazine of Concrete Research","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2023-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magazine of Concrete Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1680/jmacr.22.00181","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

The influence of the hardening accelerator and steel fiber on the concrete adhesion strength for the repair of rigid highway and airfield pavements has been investigated. The concretes were mixed based on the CEM II/A-S 42.5 and included MasterGlenium SKY 608 superplasticizer. Experiment with two variable concrete composition factors was carried out. The amount of steel fiber varied from 0 to 100 kg/m3, the amount of Sika Rapid hardening accelerator varied from 0 to 9.6 kg/m3. It was found that modified repair concretes have a sufficiently high adhesion strength to "old" concrete, from 2.30 MPa when tested by the pull-off method and from 2.05 MPa when tested by the flexural strength test method. Fiber-reinforcement increases the adhesion strength of repair concrete by 7-15% due to reducing of shrinkage during hardening. Treating the contact surface of "old" concrete with a primer additionally increases adhesion strength by 6-10%. The maximum adhesion strength of fiber-reinforced concrete to the base reaches 3 MPa. Due to the high early and design strength, modified steel fiber-reinforced concrete provides the possibility of quick resumption of traffic while ensuring the integrity of the road structure due to the joint work of the repair material with the old concrete repair area.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
纤维和硬化促进剂对刚性路面混凝土的影响
研究了硬化促进剂和钢纤维对刚性公路和机场路面修补用混凝土粘结强度的影响。混凝土根据CEM II/A-S 42.5进行混合,包括MasterGlenium SKY 608高效减水剂。采用两种不同的混凝土组成因素进行了试验。钢纤维的量在0-100kg/m3之间变化,Sika快速硬化促进剂的量在0-9.6kg/m3之间变化。研究发现,改性修补混凝土对“旧”混凝土具有足够高的粘附强度,通过拔出法测试时为2.30MPa,通过弯曲强度测试方法测试时为2.05MPa。纤维加固由于减少了硬化过程中的收缩,使修补混凝土的粘结强度提高了7-15%。用底漆处理“旧”混凝土的接触表面可额外提高6-10%的粘合强度。纤维混凝土与基层的最大粘结强度达到3MPa。由于早期和设计强度高,改性钢纤维混凝土提供了快速恢复交通的可能性,同时由于修复材料与旧混凝土修复区域的联合工作,确保了道路结构的完整性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Magazine of Concrete Research
Magazine of Concrete Research 工程技术-材料科学:综合
CiteScore
4.60
自引率
11.10%
发文量
102
审稿时长
5 months
期刊介绍: For concrete and other cementitious derivatives to be developed further, we need to understand the use of alternative hydraulically active materials used in combination with plain Portland Cement, sustainability and durability issues. Both fundamental and best practice issues need to be addressed. Magazine of Concrete Research covers every aspect of concrete manufacture and behaviour from performance and evaluation of constituent materials to mix design, testing, durability, structural analysis and composite construction.
期刊最新文献
Characterisation proposal of direct shear strength of steel fibre-reinforced concrete Punching shear tests and design of UHTCC-enhanced RC slab-column joints with shear reinforcements Engineering and microstructural properties of self-compacting concrete containing coarse recycled concrete aggregate Modelling chloride diffusion in concrete with carbonated surface layer Shear friction capacity of monolithic construction joints reinforced with self-prestressing reinforcing steel bars
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1