{"title":"Effect of crack control approaches around opening on out-of-plane flexural response of walls","authors":"H. R. Wang, K. H. Yang, H. Yoon, J. Lee","doi":"10.1080/24705314.2023.2165467","DOIUrl":null,"url":null,"abstract":"ABSTRACT This study aimed to investigate the effect of different crack-control devices at the re-entrant corners of openings on the out-of-plane flexural performance of reinforced concrete walls. The conventional diagonal bar arrangement, stress dispersion shell plate, and crack-control strip were arranged at each corner of the opening to control the localized diagonal tension cracks at the re-entrants. Four wall specimens with window openings were tested under constant axial loads and cyclic out-of-plane lateral loads. The actual cover thickness was considered in the prediction of the flexural strength of the walls. The out-of-plane flexural lateral load – lateral displacement response of the walls was not dependent on the crack-control devices but was appreciably affected by the cover thickness. An increase in the cover thickness leads to a decrease in the lateral load capacity and ductility. The out-of-plane moment capacity of walls could be conservatively assessed by a conventional flexural analysis procedure, such as the equivalent stress block for reinforced concrete structures, regardless of the consideration of crack-control devices.","PeriodicalId":43844,"journal":{"name":"Journal of Structural Integrity and Maintenance","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2023-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Structural Integrity and Maintenance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/24705314.2023.2165467","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0
Abstract
ABSTRACT This study aimed to investigate the effect of different crack-control devices at the re-entrant corners of openings on the out-of-plane flexural performance of reinforced concrete walls. The conventional diagonal bar arrangement, stress dispersion shell plate, and crack-control strip were arranged at each corner of the opening to control the localized diagonal tension cracks at the re-entrants. Four wall specimens with window openings were tested under constant axial loads and cyclic out-of-plane lateral loads. The actual cover thickness was considered in the prediction of the flexural strength of the walls. The out-of-plane flexural lateral load – lateral displacement response of the walls was not dependent on the crack-control devices but was appreciably affected by the cover thickness. An increase in the cover thickness leads to a decrease in the lateral load capacity and ductility. The out-of-plane moment capacity of walls could be conservatively assessed by a conventional flexural analysis procedure, such as the equivalent stress block for reinforced concrete structures, regardless of the consideration of crack-control devices.