Comparison of Sharp Dissection, Electrocautery, and Ultrasonic Activated Scalpel with Regard to Endothelial Damage, Preparation Time, and Postoperative Bleeding During Radial Artery Harvesting
Dinçer Uysal, Ş. Gülmen, Hayrettin Özkan, Ulaş Sağlam, M. Etli, S. Bircan, R. Sütçü, T. Yavuz, Hakan Öntaş, F. Aksoy
{"title":"Comparison of Sharp Dissection, Electrocautery, and Ultrasonic Activated Scalpel with Regard to Endothelial Damage, Preparation Time, and Postoperative Bleeding During Radial Artery Harvesting","authors":"Dinçer Uysal, Ş. Gülmen, Hayrettin Özkan, Ulaş Sağlam, M. Etli, S. Bircan, R. Sütçü, T. Yavuz, Hakan Öntaş, F. Aksoy","doi":"10.21470/1678-9741-2018-0311","DOIUrl":null,"url":null,"abstract":"Objective To examine the effects of classical technique, electrocautery, and ultrasonic dissection on endothelial integrity, function, and preparation time for harvesting the radial artery (RA) during coronary artery bypass grafting (CABG). Methods Forty-five patients who underwent isolated CABG and whose RA was suitable for use were studied and divided into three groups: Group 1, classical method (using sharp dissection); Group 2, electrocautery; and Group 3, ultrasonic cautery. Levels of prostacyclin and nitric oxide derivatives were examined biochemically; vascular cell adhesion molecule 1 (VCAM-1) and endothelial nitric oxide synthetase (eNOS) values were assessed using immunohistochemical staining. RA preparation time, RA length/harvesting time ratio, and drainage amounts at the site of RA removal were compared. Results Differences in RA preparation time (Group 1: 25±6 min, Group 2: 18±3 min, Group 3: 16±3 min, P<0.001) and length/harvesting time ratio (Group 1: 0.76±0.19 cm/min, Group 2: 0.98±0.16 cm/min, Group 3: 1.13±0.09 cm/min, P<0.001) were statistically significant among the groups. Levels of prostacyclin and nitric oxide derivatives were not statistically significant different, VCAM-1 and eNOS expressions were observed to be similar among the groups, and endothelial damage was detected in only one patient per group. Conclusion Use of ultrasonic cautery during RA preparation considerably reduces the preparation time and postoperative drainage amount. However, the superiority of one method over the others could not be demonstrated when the presence of endothelial damage with both biochemical and histopathological evaluations was considered.","PeriodicalId":54481,"journal":{"name":"Revista Brasileira De Cirurgia Cardiovascular","volume":"34 1","pages":"667 - 673"},"PeriodicalIF":1.1000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira De Cirurgia Cardiovascular","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21470/1678-9741-2018-0311","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 3
Abstract
Objective To examine the effects of classical technique, electrocautery, and ultrasonic dissection on endothelial integrity, function, and preparation time for harvesting the radial artery (RA) during coronary artery bypass grafting (CABG). Methods Forty-five patients who underwent isolated CABG and whose RA was suitable for use were studied and divided into three groups: Group 1, classical method (using sharp dissection); Group 2, electrocautery; and Group 3, ultrasonic cautery. Levels of prostacyclin and nitric oxide derivatives were examined biochemically; vascular cell adhesion molecule 1 (VCAM-1) and endothelial nitric oxide synthetase (eNOS) values were assessed using immunohistochemical staining. RA preparation time, RA length/harvesting time ratio, and drainage amounts at the site of RA removal were compared. Results Differences in RA preparation time (Group 1: 25±6 min, Group 2: 18±3 min, Group 3: 16±3 min, P<0.001) and length/harvesting time ratio (Group 1: 0.76±0.19 cm/min, Group 2: 0.98±0.16 cm/min, Group 3: 1.13±0.09 cm/min, P<0.001) were statistically significant among the groups. Levels of prostacyclin and nitric oxide derivatives were not statistically significant different, VCAM-1 and eNOS expressions were observed to be similar among the groups, and endothelial damage was detected in only one patient per group. Conclusion Use of ultrasonic cautery during RA preparation considerably reduces the preparation time and postoperative drainage amount. However, the superiority of one method over the others could not be demonstrated when the presence of endothelial damage with both biochemical and histopathological evaluations was considered.
期刊介绍:
Brazilian Journal of Cardiovascular Surgery (BJCVS) is the official journal of the Brazilian Society of Cardiovascular Surgery (SBCCV). BJCVS is a bimonthly, peer-reviewed scientific journal, with regular circulation since 1986.
BJCVS aims to record the scientific and innovation production in cardiovascular surgery and promote study, improvement and professional updating in the specialty. It has significant impact on cardiovascular surgery practice and related areas.