Method development and validation for simultaneous determination of Eletriptan hydrobromide and Itopride hydrochloride from fast dissolving buccal films by using RP-HPLC
Waqar Siddique, R. M. Sarfraz, Muhammad Zaman, Riffat Khan, M. Gul, F. Asghar, Tangina Malik, A. Saif, Qurat-Ul-Ain Shamim, A. Salawi, Meshal Alshamrani, Yosif Almoshari, F. Y. Sabei
{"title":"Method development and validation for simultaneous determination of Eletriptan hydrobromide and Itopride hydrochloride from fast dissolving buccal films by using RP-HPLC","authors":"Waqar Siddique, R. M. Sarfraz, Muhammad Zaman, Riffat Khan, M. Gul, F. Asghar, Tangina Malik, A. Saif, Qurat-Ul-Ain Shamim, A. Salawi, Meshal Alshamrani, Yosif Almoshari, F. Y. Sabei","doi":"10.1556/1326.2022.01072","DOIUrl":null,"url":null,"abstract":"\n One of the most effective, rapid, and simple methods reversed-phase high-performance liquid chromatography (RP-HPLC) was used for simultaneous development and validation of Eletriptan hydrobromide (ELE HBR) and Itopride hydrochloride (ITP HCL) in combination. The method was validated based on the regulations of United States Pharmacopeia (USP) and International Conference on Harmonization (ICH) guidelines. Separation of both drugs was achieved within approximately 5 min by using a mobile phase made up of a 70:30 ratio of phosphate buffer and acetonitrile having a flow rate of 1 mL min−1. Furthermore, a comprehensive study was conducted on precision, accuracy, linearity, inter-day, intra-day studies, an assay of formulated films, and stability studies of combined prepared film. Co-efficient of correlation ranged between 0.9993, and 0.9965 for ELE HBR and ITP HCL respectively. The accuracy of the developed method was accurate as drug recoveries in both cases of ITP HCL, and ELE HBR falls between (99.87, 99.96, and 99.84%) to (99.81, 99.12, and 98.44%) respectively having a concentration range of solutions between 10, 30 and 50 μg mL−1 dilution. Films developed by using both drugs in combination were then validated for assay studies, and it was found that substantial results of 99.05%, and 99.87% were found in the case of ITP HCL and ELE HBR respectively. The stability of the solution and mobile phase showed the method's accuracy as the results were 97% for ITP HCL and 99% for ELE HBR. The proposed method developed for simultaneous determination of ITP HCL and ELE HBR was developed and validation and no interaction of any excipient were found.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2022.01072","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1
Abstract
One of the most effective, rapid, and simple methods reversed-phase high-performance liquid chromatography (RP-HPLC) was used for simultaneous development and validation of Eletriptan hydrobromide (ELE HBR) and Itopride hydrochloride (ITP HCL) in combination. The method was validated based on the regulations of United States Pharmacopeia (USP) and International Conference on Harmonization (ICH) guidelines. Separation of both drugs was achieved within approximately 5 min by using a mobile phase made up of a 70:30 ratio of phosphate buffer and acetonitrile having a flow rate of 1 mL min−1. Furthermore, a comprehensive study was conducted on precision, accuracy, linearity, inter-day, intra-day studies, an assay of formulated films, and stability studies of combined prepared film. Co-efficient of correlation ranged between 0.9993, and 0.9965 for ELE HBR and ITP HCL respectively. The accuracy of the developed method was accurate as drug recoveries in both cases of ITP HCL, and ELE HBR falls between (99.87, 99.96, and 99.84%) to (99.81, 99.12, and 98.44%) respectively having a concentration range of solutions between 10, 30 and 50 μg mL−1 dilution. Films developed by using both drugs in combination were then validated for assay studies, and it was found that substantial results of 99.05%, and 99.87% were found in the case of ITP HCL and ELE HBR respectively. The stability of the solution and mobile phase showed the method's accuracy as the results were 97% for ITP HCL and 99% for ELE HBR. The proposed method developed for simultaneous determination of ITP HCL and ELE HBR was developed and validation and no interaction of any excipient were found.
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.