{"title":"A quantitative evaluation of the 2nd derivative mode in electron energy loss spectroscopy","authors":"J.G. Tobin","doi":"10.1016/j.elspec.2023.147387","DOIUrl":null,"url":null,"abstract":"<div><p><span><span>The second derivative mode of peak analysis in electron energy loss spectroscopy (EELS) in a Transmission </span>Electron Microscope (TEM) has been quantitatively evaluated in terms of the accuracy of the method. This includes a demonstration of the importance of the second derivative peak width, the second order dependency of the accuracy upon that peak width and effect of high frequency noise in the spectra. It is shown that while the second derivative method is an efficacious and powerful mode of analysis, there are limitations in terms of the number of significant digits in both the spectral values and derived electronic quantities. The case of uranium N</span><sub>4,5</sub> spectral peaks and the 5f population is presented as an example, with UO<sub>2</sub><span> X-ray Absorption Spectroscopy used as a benchmark.</span></p></div>","PeriodicalId":15726,"journal":{"name":"Journal of Electron Spectroscopy and Related Phenomena","volume":"268 ","pages":"Article 147387"},"PeriodicalIF":1.8000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electron Spectroscopy and Related Phenomena","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0368204823001044","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0
Abstract
The second derivative mode of peak analysis in electron energy loss spectroscopy (EELS) in a Transmission Electron Microscope (TEM) has been quantitatively evaluated in terms of the accuracy of the method. This includes a demonstration of the importance of the second derivative peak width, the second order dependency of the accuracy upon that peak width and effect of high frequency noise in the spectra. It is shown that while the second derivative method is an efficacious and powerful mode of analysis, there are limitations in terms of the number of significant digits in both the spectral values and derived electronic quantities. The case of uranium N4,5 spectral peaks and the 5f population is presented as an example, with UO2 X-ray Absorption Spectroscopy used as a benchmark.
期刊介绍:
The Journal of Electron Spectroscopy and Related Phenomena publishes experimental, theoretical and applied work in the field of electron spectroscopy and electronic structure, involving techniques which use high energy photons (>10 eV) or electrons as probes or detected particles in the investigation.