Validated UPLC-MS/MS method for the determination of ivosidenib in rat plasma: Application to a pharmacokinetic study

IF 1.7 4区 化学 Q3 CHEMISTRY, ANALYTICAL Acta Chromatographica Pub Date : 2022-08-26 DOI:10.1556/1326.2022.01053
Minle Chen, Jia Xu, Feifei Chen, Quan Zhou, Shuanghu Wang, Aixia Han
{"title":"Validated UPLC-MS/MS method for the determination of ivosidenib in rat plasma: Application to a pharmacokinetic study","authors":"Minle Chen, Jia Xu, Feifei Chen, Quan Zhou, Shuanghu Wang, Aixia Han","doi":"10.1556/1326.2022.01053","DOIUrl":null,"url":null,"abstract":"\n Ivosidenib (AG-120) is an unlisted, but estimated to be valid, oral inhibitor for isocitrate dehydrogenase 1 (IDH1) in the phase Ⅰ study of IDH1-mutated acute myeloid leukemia (AML) patients. This paper presents the investigation and validation of a rapid, effective, qualitative and quantitative determination method of ivosidenib in rat plasma by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). The samples were treated using acetonitrile precipitation to remove protein influence. Then, the supernatant was extracted to analyze plasma concentration traits. In the UPLC system, acetonitrile and water containing 0.1% formic acid were selected as a cosolvent mobile phase, applying a gradient elution to isolate compounds in a C18 column. Mass detections were performed on a triple quadruple mass spectrometer in positive ion mode. Electroshock characteristic fragment ionization was used for m/z 583.95→214.53 for ivosidenib for quantitative determination, m/z 583.95→186.6 for qualitative determination, and m/z 492.06→354.55 for IS. The selectivity, linearity, stability, accuracy and precision were verified by reaching the guideline criteria from European Medicine Agency (EMA) and the Food and Drug Administration (FDA). The calibration curve was linear over the concentration range of 2–2,000 ng mL−1 for ivosidenib in rat plasma with a lower limit of quantification (LLOQ) of at least 2 ng mL−1. Additionally, there was no distinct matrix effect or carry-over phenomenon. The method was successfully established and applied to separate ivosidenib from plasma, with the entire analytical process being performed within 3 min for each sample, which shows high-efficiency and convenience for further studies of ivosidenib.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2022-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2022.01053","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Ivosidenib (AG-120) is an unlisted, but estimated to be valid, oral inhibitor for isocitrate dehydrogenase 1 (IDH1) in the phase Ⅰ study of IDH1-mutated acute myeloid leukemia (AML) patients. This paper presents the investigation and validation of a rapid, effective, qualitative and quantitative determination method of ivosidenib in rat plasma by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). The samples were treated using acetonitrile precipitation to remove protein influence. Then, the supernatant was extracted to analyze plasma concentration traits. In the UPLC system, acetonitrile and water containing 0.1% formic acid were selected as a cosolvent mobile phase, applying a gradient elution to isolate compounds in a C18 column. Mass detections were performed on a triple quadruple mass spectrometer in positive ion mode. Electroshock characteristic fragment ionization was used for m/z 583.95→214.53 for ivosidenib for quantitative determination, m/z 583.95→186.6 for qualitative determination, and m/z 492.06→354.55 for IS. The selectivity, linearity, stability, accuracy and precision were verified by reaching the guideline criteria from European Medicine Agency (EMA) and the Food and Drug Administration (FDA). The calibration curve was linear over the concentration range of 2–2,000 ng mL−1 for ivosidenib in rat plasma with a lower limit of quantification (LLOQ) of at least 2 ng mL−1. Additionally, there was no distinct matrix effect or carry-over phenomenon. The method was successfully established and applied to separate ivosidenib from plasma, with the entire analytical process being performed within 3 min for each sample, which shows high-efficiency and convenience for further studies of ivosidenib.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经验证的UPLC-MS/MS法测定大鼠血浆中伊沃西替尼:在药代动力学研究中的应用
Ivosidenib (AG-120)是一种未上市但估计有效的口服异柠檬酸脱氢酶1 (IDH1)抑制剂,用于IDH1突变的急性髓性白血病(AML)患者的Ⅰ期研究。建立了一种快速、有效、定性、定量测定大鼠血浆中伊沃西地尼的超高效液相色谱-串联质谱(UPLC-MS/MS)方法。样品用乙腈沉淀法去除蛋白质的影响。然后提取上清液分析血浆浓度特征。在UPLC系统中,选择含有0.1%甲酸的乙腈和水作为共溶剂流动相,在C18柱中采用梯度洗脱分离化合物。在正离子模式下,用三联四联质谱仪进行质量检测。用m/z 583.95→214.53进行ivosidenib定量测定,m/z 583.95→186.6进行定性测定,m/z 492.06→354.55进行IS定量测定。通过符合欧洲药品管理局(EMA)和美国食品药品监督管理局(FDA)的指导标准,验证了该方法的选择性、线性度、稳定性、准确度和精密度。ivosidenib在大鼠血浆浓度2 ~ 2000 ng mL−1范围内呈线性,定量下限(LLOQ)至少为2 ng mL−1。此外,没有明显的基质效应和结转现象。该方法成功建立并应用于ivosidenib与血浆的分离,每个样品的整个分析过程在3 min内完成,为进一步研究ivosidenib提供了高效率和便捷性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta Chromatographica
Acta Chromatographica 化学-分析化学
CiteScore
4.00
自引率
0.00%
发文量
55
审稿时长
2.3 months
期刊介绍: Acta Chromatographica Open Access Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.
期刊最新文献
A comprehensive assessment of the biological attributes of and analytical quantification methods for monosodium glutamate Evaluation of the RP-LC method for determining the pKa of abiraterone and its assay Development, validation and greenness assessment of environmentally friendly analytical methods for the quantification of lenalidomide in pharmaceutical formulations Green RP-HPLC methods for assay and related substances in rivaroxaban tablets Simultaneous qualitative and quantitative analysis for evaluating constituents of Atractylodis macrocephalae rhizome by UPLC-QTOF-MS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1