{"title":"An Experimental Study on the Bubble Column Performance of Two Phases","authors":"Moayad Salih","doi":"10.32894/kujss.2019.14.1.14","DOIUrl":null,"url":null,"abstract":"Bubble columns are form commend industrial instruments which is widely used in factorial petrochemical and biochemical aspects especially in absorption and reactions between gas and the liquid. The study aimed to study the effects of both the superficial gas velocity for ranges (152.24) m /s and pressure ranges for (0.5-2) kg /cm and diameter holes (1,2,2.5) mm in gas distributor from perforated plate for electrolytic solutions (0.05 N NaCl, 0.02 N CaCl2, 0.1 N Na2SO4 ) to volume percentage for holden gas in solution and mass transfer coefficient ratio. The experimental device was used on the bubble column length (2m) diameter (0.2) m and thickness (0.01) m. The study result show that high volumetric percent at concentration (0.02 N CaCl2 ) was (7.65) due to its dependence on superficial gas velocity while the higher volume holdup gas in solution at concentration( 0.05 N Nacl) was (7.96) because of higher pressure which cause in decreasing the mass transfer coefficient ratio which is increase with the gas superficial surface in solution at concentration level ( 0.1 N Na2SO4 ) and the is occur due to bubble volume is higher when pressure increase.","PeriodicalId":34247,"journal":{"name":"mjl@ jm`@ krkwk ldrst l`lmy@","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"mjl@ jm`@ krkwk ldrst l`lmy@","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32894/kujss.2019.14.1.14","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Bubble columns are form commend industrial instruments which is widely used in factorial petrochemical and biochemical aspects especially in absorption and reactions between gas and the liquid. The study aimed to study the effects of both the superficial gas velocity for ranges (152.24) m /s and pressure ranges for (0.5-2) kg /cm and diameter holes (1,2,2.5) mm in gas distributor from perforated plate for electrolytic solutions (0.05 N NaCl, 0.02 N CaCl2, 0.1 N Na2SO4 ) to volume percentage for holden gas in solution and mass transfer coefficient ratio. The experimental device was used on the bubble column length (2m) diameter (0.2) m and thickness (0.01) m. The study result show that high volumetric percent at concentration (0.02 N CaCl2 ) was (7.65) due to its dependence on superficial gas velocity while the higher volume holdup gas in solution at concentration( 0.05 N Nacl) was (7.96) because of higher pressure which cause in decreasing the mass transfer coefficient ratio which is increase with the gas superficial surface in solution at concentration level ( 0.1 N Na2SO4 ) and the is occur due to bubble volume is higher when pressure increase.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两相鼓泡塔性能的实验研究
气泡塔是一种优良的工业仪器,广泛应用于石化、生化等方面,特别是气液两相的吸收和反应。研究电解溶液(0.05 N NaCl、0.02 N CaCl2、0.1 N Na2SO4)用多孔板配气器表面气速(152.24)m /s、压力(0.5-2)kg /cm、孔径(1、2、2.5)mm对溶液中气体体积百分比和传质系数比的影响。实验装置是用于泡沫柱长度(2米)直径(0.2)米,厚度(0.01)米。研究结果表明,高体积百分比浓度(0.02 N氯化钙)(7.65)由于其表面气体速度的依赖而体积抢劫气体在溶液浓度越高(0.05 N氯化钠)高(7.96),因为压力导致减少的传质系数比增加气体在溶液中肤浅的表面的浓度水平(0.1 N Na2SO4),气泡体积随着压力的增加而增大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
3
审稿时长
10 weeks
期刊最新文献
Effect of Nd:YAG Laser’s Wavelength on the Optical Properties of Agarose Thin Films Determination of some hematological, biochemical parameters and vitamin D receptor gene polymorphism in Kurdish patients with COVID-19 in Erbil city Study of positive parity states form factors for 17O nucleus with Skyrme-Hartree-Fock method A New Paired Spectral Gradient Method to Improve Unconstrained and Non-Linear Optimization The Impact of the Normality of Two Types of Chemical Solutions on the Etching Rates of Nuclear Track detector CR-39
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1