Implementation of different separation techniques for resolving ternary mixture of Paracetamol, Pseudoephedrine Hydrochloride and Chlorpheniramine maleate with further quantification
Joliana F Farid, N. Mostafa, Hebatallah M Essam, Y. Fayez
{"title":"Implementation of different separation techniques for resolving ternary mixture of Paracetamol, Pseudoephedrine Hydrochloride and Chlorpheniramine maleate with further quantification","authors":"Joliana F Farid, N. Mostafa, Hebatallah M Essam, Y. Fayez","doi":"10.1556/1326.2021.00954","DOIUrl":null,"url":null,"abstract":"\n Due to the wide applicability of separation techniques that rely on the property of differential migration in pharmaceutical formulations analysis, different analytical strategies have been proposed to resolve mixtures of multi-components pharmaceuticals. Three separation methods were developed and validated for the simultaneous determination of Paracetamol (PAR), Pseudoephedrine HCl (PSE) and Chlorpheniramine maleate (CHP). The first method is a thin-layer chromatographic (TLC) separation, followed by densitometric measurement. The separation was carried out on aluminium sheet of silica gel 60 F254 using ethanol:chloroform:ammonia (1:7:0.4, by volume) as the mobile phase. Determination of PAR, PSE and CHP was successfully applied over the concentration ranges of 3–25 µg/band, 0.5–10 µg/band and 0.1–6 µg/band, respectively. The second method is HPLC separation that was achieved on C18 column using the mobile phase acetonitrile:phosphate buffer pH 5 (10:90, v/v) at a flow rate 1 mL min−1. PAR, PSE and CHP were determined by HPLC in concentration ranges of 5–400 μg mL−1, 2–40 μg mL−1 and 0.5–16 μg mL−1, respectively. The third method is a capillary electrophoresis (CE) separation. The electrophoretic separation was achieved using 20 mM phosphate buffer (pH 6.5) at 20 kV. The linearity was reached over concentration ranges of 30–250 μg mL−1, 5–50 μg mL−1 and 0.8–20 μg mL−1 for PAR, PSE and CHP, respectively. The developed methods were validated with respect to linearity, precision, accuracy and system suitability. The proposed methods were successfully applied for bulk powder and dosage form analysis with RSD of precision <2%. Moreover, statistical comparison with the official methods confirms the methods' validity.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2021.00954","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Due to the wide applicability of separation techniques that rely on the property of differential migration in pharmaceutical formulations analysis, different analytical strategies have been proposed to resolve mixtures of multi-components pharmaceuticals. Three separation methods were developed and validated for the simultaneous determination of Paracetamol (PAR), Pseudoephedrine HCl (PSE) and Chlorpheniramine maleate (CHP). The first method is a thin-layer chromatographic (TLC) separation, followed by densitometric measurement. The separation was carried out on aluminium sheet of silica gel 60 F254 using ethanol:chloroform:ammonia (1:7:0.4, by volume) as the mobile phase. Determination of PAR, PSE and CHP was successfully applied over the concentration ranges of 3–25 µg/band, 0.5–10 µg/band and 0.1–6 µg/band, respectively. The second method is HPLC separation that was achieved on C18 column using the mobile phase acetonitrile:phosphate buffer pH 5 (10:90, v/v) at a flow rate 1 mL min−1. PAR, PSE and CHP were determined by HPLC in concentration ranges of 5–400 μg mL−1, 2–40 μg mL−1 and 0.5–16 μg mL−1, respectively. The third method is a capillary electrophoresis (CE) separation. The electrophoretic separation was achieved using 20 mM phosphate buffer (pH 6.5) at 20 kV. The linearity was reached over concentration ranges of 30–250 μg mL−1, 5–50 μg mL−1 and 0.8–20 μg mL−1 for PAR, PSE and CHP, respectively. The developed methods were validated with respect to linearity, precision, accuracy and system suitability. The proposed methods were successfully applied for bulk powder and dosage form analysis with RSD of precision <2%. Moreover, statistical comparison with the official methods confirms the methods' validity.
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.