Effects of Cuspal Inclination and Luting Agent on Fracture Load Values in Composite Resin CAD/CAM Crowns.

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Bulletin of Tokyo Dental College Pub Date : 2022-05-25 DOI:10.2209/tdcpublication.2020-0017
{"title":"Effects of Cuspal Inclination and Luting Agent on Fracture Load Values in Composite Resin CAD/CAM Crowns.","authors":"Gen Kuroishi, Mamoru Yotsuya, Syuntaro Nomoto, R. Hisanaga, Toru Sato","doi":"10.2209/tdcpublication.2020-0017","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to evaluate whether change in cuspal inclination influences the fracture load values of composite resin computer-aided design/computer-aided manufacturing (CAD/CAM) crowns. Abutment teeth and CAD/CAM crowns were prepared as they would be for treating a mandibular first premolar with two cusps. The CAD/CAM crowns were designed so that 1) the principal stress lines would be radially distributed from the two points of contact with the indenter to the occlusal area of the abutment (Type I), or 2) the principal stress lines would pass outside the occlusal area of the abutment (Types II and III). The CAD/CAM crowns were mounted on the abutments using one of two types of resin or polycarboxylate cement. Fracture load values were measured using a universal tester. The Type I CAD/CAM crowns exhibited the highest mean fracture load value, followed by the Type II crowns and then the Type III crowns, with significant differences seen between all types (p<0.05). The luting agent used (resin or polycarboxylate cement) showed no effect on the fracture load value. With the Type II and Type III crowns, significant differences in the fracture load value were observed between the Super-Bond and Hy-Bond polycarboxylate cement groups (p<0.05).","PeriodicalId":45490,"journal":{"name":"Bulletin of Tokyo Dental College","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2022-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Tokyo Dental College","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2209/tdcpublication.2020-0017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

The purpose of this study was to evaluate whether change in cuspal inclination influences the fracture load values of composite resin computer-aided design/computer-aided manufacturing (CAD/CAM) crowns. Abutment teeth and CAD/CAM crowns were prepared as they would be for treating a mandibular first premolar with two cusps. The CAD/CAM crowns were designed so that 1) the principal stress lines would be radially distributed from the two points of contact with the indenter to the occlusal area of the abutment (Type I), or 2) the principal stress lines would pass outside the occlusal area of the abutment (Types II and III). The CAD/CAM crowns were mounted on the abutments using one of two types of resin or polycarboxylate cement. Fracture load values were measured using a universal tester. The Type I CAD/CAM crowns exhibited the highest mean fracture load value, followed by the Type II crowns and then the Type III crowns, with significant differences seen between all types (p<0.05). The luting agent used (resin or polycarboxylate cement) showed no effect on the fracture load value. With the Type II and Type III crowns, significant differences in the fracture load value were observed between the Super-Bond and Hy-Bond polycarboxylate cement groups (p<0.05).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
复合树脂CAD/CAM牙冠中牙尖倾斜度和胶合剂对断裂载荷值的影响。
本研究的目的是评估牙尖倾斜度的变化是否会影响复合树脂计算机辅助设计/计算机辅助制造(CAD/CAM)牙冠的断裂载荷值。制备了基牙和CAD/CAM牙冠,因为它们将用于治疗具有两个尖的下颌第一前磨牙。CAD/CAM牙冠的设计使得1)主应力线将从与压头的两个接触点径向分布到基牙的咬合区域(类型I),或者2)主应力线将穿过基牙的牙咬合区域之外(类型II和III)。使用两种类型的树脂或聚羧酸水泥中的一种将CAD/CAM牙冠安装在基牙上。使用通用测试仪测量断裂载荷值。I型CAD/CAM冠的平均断裂载荷值最高,其次是II型冠,然后是III型冠,所有类型之间存在显著差异(p<0.05)。所用的粘接剂(树脂或聚羧酸水泥)对断裂载荷值没有影响。对于II型和III型牙冠,Super-Bond和Hy-Bond聚羧酸水泥组之间的断裂载荷值存在显著差异(p<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
相关文献
Effects of two silane coupling agents, a bonding agent, and thermal cycling on the bond strength of a CAD/CAM composite material cemented with two resin luting agents
IF 4.6 2区 医学Journal of Prosthetic DentistryPub Date : 2001-02-01 DOI: 10.1067/mpr.2001.113628
Keiichi Yoshida DDS, PhDa, Kohji Kamada DDSb, Mitsuru Atsuta DDS, PhDc
来源期刊
Bulletin of Tokyo Dental College
Bulletin of Tokyo Dental College DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: The bulletin of Tokyo Dental collegue is principally for the publication of original contributions to multidisciplinary research in dentistry.
期刊最新文献
An Orthodontic Study of Non-syndromic Oligodontia: An Examination of Occlusion and Occlusal Support. Complex Odontoma Initially Suspected to be Eruption Sequestrum. Effect of Porphyromonas Gingivalis Infection on Epithelial Rests of Malassez. Periodontal Surgery Using Recombinant Human Fibroblast Growth Factor-2 in Combination with Carbonate Apatite Granules for Stage III Grade C Periodontitis: A 30-month Case Report. Treponema Denticola Activates NF-κB Pathway via Toll-like Receptor 2.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1