E. Ozkan, Gulay Dumanli Gok, N. E. Ordueri, T. Elgun
{"title":"Cytotoxicity evaluation of different clear aligner materials using MTT analysis","authors":"E. Ozkan, Gulay Dumanli Gok, N. E. Ordueri, T. Elgun","doi":"10.2478/aoj-2022-0034","DOIUrl":null,"url":null,"abstract":"Abstract Backround: The in vitro cytotoxic effects of six different clear aligner materials were evaluated using the MTT analysis. Methods: The clear aligner material samples [Duran (ScheuDental GmbH, Iserlohn, Germany), Zendura-Flx (Bay Materials LLC, Fremont, CA, USA), Taglus (Laxmi Dental Export Pvt. Ltd, Mumbai, India), Smart Track (Align Technology, San Jose, CA, USA), Zendura (Bay Materials LLC, Fremont, CA, USA), Essix C + (Essix® (Raintree Essix, Inc., 4001 Division St, Metairie, LA-USA)] were initially kept in a saline solution in airtight test tubes for 8 weeks at 37°C. According to the recommended ISO standards, the weights of the samples were divided by the volumes of the dilutions in the ratio of 0.1 g/ml. To evaluate the cytotoxicity of the samples, an MTT analysis was performed using a human gingival fibroblast cell line (HGF). To analyse the data, the Kruskal– Wallis test was applied (a=0.05). Results: Zendura was the most cytotoxic material resulting in 67.3 ± 16.20% cell viability, followed by Smart Track with 87.6 ± 5.53% cell viability. While Duran, Essix C + had 92.6 ± 26.34% and 94.9 ± 8.54% cell viability, Zendura-Flx, Taglus had 106.9 ± 12.76% and 113.183 ± 7.45% cell viability, respectively. Conclusion: While Zendura and Smart Track showed mild cytotoxicity, other materials showed greater cell viabilities. According to the ISO standards, the clinical use of each brand of aligners, except Zendura, may be considered reliable. Taking into account standard deviation, Zendura and Duran should be used with caution. The suppliers of aligners should adhere to the manufacturer’s recommendations since an increase in ion release might arise from material wear.","PeriodicalId":48559,"journal":{"name":"Australasian Orthodontic Journal","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australasian Orthodontic Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2478/aoj-2022-0034","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2
Abstract
Abstract Backround: The in vitro cytotoxic effects of six different clear aligner materials were evaluated using the MTT analysis. Methods: The clear aligner material samples [Duran (ScheuDental GmbH, Iserlohn, Germany), Zendura-Flx (Bay Materials LLC, Fremont, CA, USA), Taglus (Laxmi Dental Export Pvt. Ltd, Mumbai, India), Smart Track (Align Technology, San Jose, CA, USA), Zendura (Bay Materials LLC, Fremont, CA, USA), Essix C + (Essix® (Raintree Essix, Inc., 4001 Division St, Metairie, LA-USA)] were initially kept in a saline solution in airtight test tubes for 8 weeks at 37°C. According to the recommended ISO standards, the weights of the samples were divided by the volumes of the dilutions in the ratio of 0.1 g/ml. To evaluate the cytotoxicity of the samples, an MTT analysis was performed using a human gingival fibroblast cell line (HGF). To analyse the data, the Kruskal– Wallis test was applied (a=0.05). Results: Zendura was the most cytotoxic material resulting in 67.3 ± 16.20% cell viability, followed by Smart Track with 87.6 ± 5.53% cell viability. While Duran, Essix C + had 92.6 ± 26.34% and 94.9 ± 8.54% cell viability, Zendura-Flx, Taglus had 106.9 ± 12.76% and 113.183 ± 7.45% cell viability, respectively. Conclusion: While Zendura and Smart Track showed mild cytotoxicity, other materials showed greater cell viabilities. According to the ISO standards, the clinical use of each brand of aligners, except Zendura, may be considered reliable. Taking into account standard deviation, Zendura and Duran should be used with caution. The suppliers of aligners should adhere to the manufacturer’s recommendations since an increase in ion release might arise from material wear.
期刊介绍:
The Australasian Orthodontic Journal (AOJ) is the official scientific publication of the Australian Society of Orthodontists.
Previously titled the Australian Orthodontic Journal, the name of the publication was changed in 2017 to provide the region with additional representation because of a substantial increase in the number of submitted overseas'' manuscripts. The volume and issue numbers continue in sequence and only the ISSN numbers have been updated.
The AOJ publishes original research papers, clinical reports, book reviews, abstracts from other journals, and other material which is of interest to orthodontists and is in the interest of their continuing education. It is published twice a year in November and May.
The AOJ is indexed and abstracted by Science Citation Index Expanded (SciSearch) and Journal Citation Reports/Science Edition.