Radiological Evaluation and Biomechanical Stability of Implants Simultaneously Placed at the Sites with Sole Advanced Platelet-Rich Fibrin (A-PRF) Grafted Sinus Floor.
{"title":"Radiological Evaluation and Biomechanical Stability of Implants Simultaneously Placed at the Sites with Sole Advanced Platelet-Rich Fibrin (A-PRF) Grafted Sinus Floor.","authors":"Necip Fazıl Erdem, Gürkan Abdioğlu, Senem Aşkın Ekinci, Alanur Çiftçi Şişman","doi":"10.1007/s12663-022-01785-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>In this retrospective study stabilities of 24 implants simultaneously placed at posterior maxillae with sinuses grafted by advanced platelet rich fibrin (A-PRF) and newly formed bone around them were evaluated.</p><p><strong>Patient and methods: </strong>Fourteen augmented maxillary sinuses of 11 patients with a mean residual alveolar bone height of 4.55 mm were involved in this study. Maxillary sinus lifting via lateral window approach and implant site osteotomy were performed, and prepared A-PRF clots were used as sole graft material. Each of the implants was immediately placed with a good primary stability. Postoperative sixth month tomography images were compared with preoperative ones in order to calculate the gained bone height and implant stability quotient (ISQ) values were recorded.</p><p><strong>Results: </strong>The new vertical mean bone height of 24 implant sites was 12.21 mm with an implant survival rate of 100%. ISQ values of the implants were ranging from 62 to 75 with a mean value of 68. Statistically the diameter of implant did not have any effect on new bone formation and the ISQ values, however the length of them did.</p><p><strong>Conclusion: </strong>A-PRF as a graft material for sinus lifting with simultaneous implant placement is a reliable technique with its low cost and lack of immunogenic reaction risk.</p>","PeriodicalId":0,"journal":{"name":"","volume":" ","pages":"1083-1090"},"PeriodicalIF":0.0,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719193/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12663-022-01785-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/20 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: In this retrospective study stabilities of 24 implants simultaneously placed at posterior maxillae with sinuses grafted by advanced platelet rich fibrin (A-PRF) and newly formed bone around them were evaluated.
Patient and methods: Fourteen augmented maxillary sinuses of 11 patients with a mean residual alveolar bone height of 4.55 mm were involved in this study. Maxillary sinus lifting via lateral window approach and implant site osteotomy were performed, and prepared A-PRF clots were used as sole graft material. Each of the implants was immediately placed with a good primary stability. Postoperative sixth month tomography images were compared with preoperative ones in order to calculate the gained bone height and implant stability quotient (ISQ) values were recorded.
Results: The new vertical mean bone height of 24 implant sites was 12.21 mm with an implant survival rate of 100%. ISQ values of the implants were ranging from 62 to 75 with a mean value of 68. Statistically the diameter of implant did not have any effect on new bone formation and the ISQ values, however the length of them did.
Conclusion: A-PRF as a graft material for sinus lifting with simultaneous implant placement is a reliable technique with its low cost and lack of immunogenic reaction risk.