Feasibility study of multi-purpose quality assurance phantom for pretreatment verification of volumetric modulated arc therapy

H. Won, J. Chung, K. Eom, D. Hwang, S. Kang, T. Suh
{"title":"Feasibility study of multi-purpose quality assurance phantom for pretreatment verification of volumetric modulated arc therapy","authors":"H. Won, J. Chung, K. Eom, D. Hwang, S. Kang, T. Suh","doi":"10.18869/ACADPUB.IJRR.16.2.279","DOIUrl":null,"url":null,"abstract":"Background: The purpose of this study was to evaluate the feasibility of a multipurpose quality assurance (QA) phantom for pretreatment verification of volumetric modulated arc therapy (VMAT). Materials and Methods: The QA phantom was constructed with polymethyl methacrylate (PMMA) to perform relative dosimetry using EBT3 film and MapCHECK, as well as absolute dosimetry using an ionization chamber. The QA phantom was constructed to perform relative dosimetry using EBT3 film and MapCHECK, as well as the absolute dosimetry using ionization chamber. In order to verify the pretreatment plans, 25 patients treated with VMAT were selected. The pretreatment plans were calculated in the Eclipse treatment planning system using the Acuros XB dose calculation algorithm and CT images for the QA phantom, with the same beam setup and monitor units (MUs) as those for patient treatment. All plans were delivered to the Varian TrueBeam accelerator equipped with a high-definition multi-leaf collimator. Results: The multi-purpose QA phantom is developed for convenient VMAT dose verification. By using the QA phantom, all 25 cases passed ±3% acceptability criteria in absolute dosimetry with an ionization chamber for pretreatment verification. The relative dosimetry using EBT3 film and MapCHECK system also showed high agreement of more than 90% for 2%/2-mm and 3%/3-mm criteria. Conclusion: The results of this study demonstrated the good multipurpose capabilities of the phantom for the absolute and relative dosimetry. Therefore, the developed multi-purpose QA phantom was applied in our institution for routine VMRT dose verification.","PeriodicalId":14498,"journal":{"name":"Iranian Journal of Radiation Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Radiation Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18869/ACADPUB.IJRR.16.2.279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 5

Abstract

Background: The purpose of this study was to evaluate the feasibility of a multipurpose quality assurance (QA) phantom for pretreatment verification of volumetric modulated arc therapy (VMAT). Materials and Methods: The QA phantom was constructed with polymethyl methacrylate (PMMA) to perform relative dosimetry using EBT3 film and MapCHECK, as well as absolute dosimetry using an ionization chamber. The QA phantom was constructed to perform relative dosimetry using EBT3 film and MapCHECK, as well as the absolute dosimetry using ionization chamber. In order to verify the pretreatment plans, 25 patients treated with VMAT were selected. The pretreatment plans were calculated in the Eclipse treatment planning system using the Acuros XB dose calculation algorithm and CT images for the QA phantom, with the same beam setup and monitor units (MUs) as those for patient treatment. All plans were delivered to the Varian TrueBeam accelerator equipped with a high-definition multi-leaf collimator. Results: The multi-purpose QA phantom is developed for convenient VMAT dose verification. By using the QA phantom, all 25 cases passed ±3% acceptability criteria in absolute dosimetry with an ionization chamber for pretreatment verification. The relative dosimetry using EBT3 film and MapCHECK system also showed high agreement of more than 90% for 2%/2-mm and 3%/3-mm criteria. Conclusion: The results of this study demonstrated the good multipurpose capabilities of the phantom for the absolute and relative dosimetry. Therefore, the developed multi-purpose QA phantom was applied in our institution for routine VMRT dose verification.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
体积调制电弧治疗前验证多用途质量保证模体的可行性研究
背景:本研究的目的是评估多用途质量保证(QA)模型用于体积调制电弧治疗(VMAT)预处理验证的可行性。材料和方法:用聚甲基丙烯酸甲酯(PMMA)构建QA模体,使用EBT3薄膜和MapCHECK进行相对剂量测定,并使用电离室进行绝对剂量测定。构建QA模体,利用EBT3薄膜和MapCHECK进行相对剂量测定,利用电离室进行绝对剂量测定。为了验证预处理方案,选择25例经VMAT治疗的患者。预处理方案在Eclipse治疗计划系统中计算,采用Acuros XB剂量计算算法和QA幻体的CT图像,与患者治疗时相同的光束设置和监护单位(MUs)。所有的计划都被交付给瓦里安TrueBeam加速器,该加速器配备了高清多叶准直器。结果:为方便VMAT剂量验证,研制了多用途QA模体。使用QA模体,25例患者均通过电离室绝对剂量法±3%可接受标准进行预处理验证。使用EBT3膜和MapCHECK系统进行相对剂量测定,对2%/2-mm和3%/3-mm标准的一致性也超过90%。结论:本研究结果证明了假体在绝对剂量和相对剂量测定中具有良好的多用途功能。因此,本研究所采用研制的多用途QA模体进行VMRT常规剂量验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iranian Journal of Radiation Research
Iranian Journal of Radiation Research RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.67
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: Iranian Journal of Radiation Research (IJRR) publishes original scientific research and clinical investigations related to radiation oncology, radiation biology, and Medical and health physics. The clinical studies submitted for publication include experimental studies of combined modality treatment, especially chemoradiotherapy approaches, and relevant innovations in hyperthermia, brachytherapy, high LET irradiation, nuclear medicine, dosimetry, tumor imaging, radiation treatment planning, radiosensitizers, and radioprotectors. All manuscripts must pass stringent peer-review and only papers that are rated of high scientific quality are accepted.
期刊最新文献
How to deal with the relationship between hypoxia and radiotherapy in the hypofractionated radiotherapy era Chemoradiotherapy alone or in combination with Endostar for patients with advanced non-small cell lung cancer: A systematic review and meta-analysis Measurement of exposure to radionuclides (40-K, 226-Ra, and 232-Th) in the oil and gas drilling industry Effects of particle size and weight percentage of heavy metal elements on photon shielding efficiency of reinforced polymer composites Dosimetric evaluation of field-in-field and sliding-window IMRT in endometrium cancer patients with a new approach for the conformity index
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1