Dosimetric parameters in congenital cardiac catheterizations in Spain: the GTH-SECPCC Radcong-21 multicenter registry

F. Rueda Núñez, C. Abelleira Pardeiro, B. Insa Albert, M. Álvarez-Fuente, Vanesa Balboa Barreiro, F. Ballesteros Tejerizo, P. Betrián-Blasco, Félix Coserría Sánchez, Juana María Espín López, Luis Fernández González, Dolores Herrera Linde, M. R. Romero Moreno, F. Sarnago Cebada, R. Sanz-Ruiz, and Juan Ignacio Zabala Argüelles
{"title":"Dosimetric parameters in congenital cardiac catheterizations in Spain: the GTH-SECPCC Radcong-21 multicenter registry","authors":"F. Rueda Núñez, C. Abelleira Pardeiro, B. Insa Albert, M. Álvarez-Fuente, Vanesa Balboa Barreiro, F. Ballesteros Tejerizo, P. Betrián-Blasco, Félix Coserría Sánchez, Juana María Espín López, Luis Fernández González, Dolores Herrera Linde, M. R. Romero Moreno, F. Sarnago Cebada, R. Sanz-Ruiz, and Juan Ignacio Zabala Argüelles","doi":"10.24875/recice.m23000372","DOIUrl":null,"url":null,"abstract":"Introduction and objectives: The results of the Radcong-21 Registry of the Spanish Society of Pediatric Cardiology and Congenital Heart Disease Working Group on Hemodynamics are described to analyze data, establish updated reference parameters, and compare them to other registries. Methods: Retrospective, cross-sectional, observational, multicenter registry of patients with congenital heart disease undergoing cardiac catheterization in 2021. Each cath lab sent the last 100 cases performed prior to January 2022. A descriptive analysis was conducted of anthropomorphic variables, procedural (grouped by type and radiation exposure categories [REC]) and technical characteristics, and dosimetric parameters with additional review of all values outside the 95%CI of the median. Results: A total of 1090 procedures performed in 11 cath lab of 10 hospital centers were analyzed. Age distribution: 22.8% < 1 year, 60.7% between 1-18 years, and 16.4% > 18 years. In dose area product (DAP)/Kg and DAP/Kg/fluoroscopy, the distribution was very similar regardless of the type of cath lab as is the case with most pediatric patients in terms of age, weight, and REC group. The DAP/Kg was higher in the REC I and III groups compared to other countries with registries and improvement programs in this area (78% and 8,3%, respectively). Conclusions: Representative data of dosimetric parameters by age and procedures in congenital cardiac catheterizations were obtained in Spain back in 2021. DAP/Kg is the parameter with the lowest dispersion in the sample. There is room for improvement compared to other countries with optimization programs in this area.","PeriodicalId":34613,"journal":{"name":"REC Interventional Cardiology English Ed","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"REC Interventional Cardiology English Ed","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24875/recice.m23000372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction and objectives: The results of the Radcong-21 Registry of the Spanish Society of Pediatric Cardiology and Congenital Heart Disease Working Group on Hemodynamics are described to analyze data, establish updated reference parameters, and compare them to other registries. Methods: Retrospective, cross-sectional, observational, multicenter registry of patients with congenital heart disease undergoing cardiac catheterization in 2021. Each cath lab sent the last 100 cases performed prior to January 2022. A descriptive analysis was conducted of anthropomorphic variables, procedural (grouped by type and radiation exposure categories [REC]) and technical characteristics, and dosimetric parameters with additional review of all values outside the 95%CI of the median. Results: A total of 1090 procedures performed in 11 cath lab of 10 hospital centers were analyzed. Age distribution: 22.8% < 1 year, 60.7% between 1-18 years, and 16.4% > 18 years. In dose area product (DAP)/Kg and DAP/Kg/fluoroscopy, the distribution was very similar regardless of the type of cath lab as is the case with most pediatric patients in terms of age, weight, and REC group. The DAP/Kg was higher in the REC I and III groups compared to other countries with registries and improvement programs in this area (78% and 8,3%, respectively). Conclusions: Representative data of dosimetric parameters by age and procedures in congenital cardiac catheterizations were obtained in Spain back in 2021. DAP/Kg is the parameter with the lowest dispersion in the sample. There is room for improvement compared to other countries with optimization programs in this area.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
西班牙先天性心脏导管的剂量参数:GTH-SECPCC Radcong-21多中心注册
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
REC Interventional Cardiology English Ed
REC Interventional Cardiology English Ed Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.70
自引率
0.00%
发文量
86
审稿时长
15 weeks
期刊最新文献
Impella-Clip: a secure and effective strategy in cardiogenic shock due to acute severe mitral regurgitation. Case resolution New TAVI technique for difficult valve crossing Marking a milestone. REC: Interventional Cardiology assigned its first impact factor Cardiac catheterization activity in pediatric cardiac transplantation. Can catheterization needs be predicted? The PULSTA valve in native right ventricular outflow tract: initial experience in 3 Spanish hospitals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1