Compact Radar Cross-Section Measurement Setup and Performance Evaluation

IF 0.6 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Advances in Radio Science Pub Date : 2021-12-17 DOI:10.5194/ars-19-147-2021
Maximilian F. Sundermeier, Dirk Fischer
{"title":"Compact Radar Cross-Section Measurement Setup and Performance Evaluation","authors":"Maximilian F. Sundermeier, Dirk Fischer","doi":"10.5194/ars-19-147-2021","DOIUrl":null,"url":null,"abstract":"Abstract. Radar cross-section measurements require the background reflections to be much lower than the reflections of the device under test. Although, anechoic chambers with special target holders meet this requirement, they are expensive and still have imperfections. To further reduce background reflections or to measure in environments where an anechoic chamber is not suitable, digital signal processing can be used to reduce background reflections. In this paper, a complete signal processing chain realized in Matlab is proposed, involving time gating of the measured target response and a background subtraction technique. Furthermore, the proposed signal processing includes a calibration procedure with either a single known calibration target or multiple known targets to improve measurement uncertainties. A compact measurement setup, consisting of a vector network analyzer and two horn antennas, is used to evaluate the overall performance and the advantages of a multiple known target calibration in a practical manner. The calibrated setup is able to measure the radar cross-section in a frequency range from 2 to 12 GHz with a mean error of less than 0.2 dB for both, VV and HH polarization combinations. It could also be shown, that a multi target calibration can result in an improvement of the measurement uncertainty by about 2.5 %.\n","PeriodicalId":45093,"journal":{"name":"Advances in Radio Science","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2021-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Radio Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/ars-19-147-2021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 2

Abstract

Abstract. Radar cross-section measurements require the background reflections to be much lower than the reflections of the device under test. Although, anechoic chambers with special target holders meet this requirement, they are expensive and still have imperfections. To further reduce background reflections or to measure in environments where an anechoic chamber is not suitable, digital signal processing can be used to reduce background reflections. In this paper, a complete signal processing chain realized in Matlab is proposed, involving time gating of the measured target response and a background subtraction technique. Furthermore, the proposed signal processing includes a calibration procedure with either a single known calibration target or multiple known targets to improve measurement uncertainties. A compact measurement setup, consisting of a vector network analyzer and two horn antennas, is used to evaluate the overall performance and the advantages of a multiple known target calibration in a practical manner. The calibrated setup is able to measure the radar cross-section in a frequency range from 2 to 12 GHz with a mean error of less than 0.2 dB for both, VV and HH polarization combinations. It could also be shown, that a multi target calibration can result in an improvement of the measurement uncertainty by about 2.5 %.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
紧凑型雷达截面测量装置及性能评估
摘要雷达截面测量要求背景反射远低于被测设备的反射。尽管具有特殊目标支架的消声室满足这一要求,但它们价格昂贵,而且仍然存在缺陷。为了进一步减少背景反射或在不适合消声室的环境中进行测量,可以使用数字信号处理来减少背景反射。本文提出了一个在Matlab中实现的完整信号处理链,包括测量目标响应的时间门控和背景减法技术。此外,所提出的信号处理包括具有单个已知校准目标或多个已知目标的校准过程,以改善测量不确定性。由矢量网络分析仪和两个喇叭天线组成的紧凑型测量装置用于以实用的方式评估多个已知目标校准的总体性能和优势。校准后的装置能够测量2至12频率范围内的雷达横截面 GHz,平均误差小于0.2 VV和HH极化组合的dB。还可以表明,多目标校准可以将测量不确定度提高约2.5 %.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advances in Radio Science
Advances in Radio Science ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
0.90
自引率
0.00%
发文量
3
审稿时长
45 weeks
期刊最新文献
MmWave scattering properties of roads on rough asphalt and concrete surfaces Y-shaped tunable monolithic dual colour lasers for THz technology Egbert von Lepel and the Invention of the Spark-Gap Transmitter Long-term trends of midlatitude horizontal mesosphere/lower thermosphere winds over four decades Approximation of High Intensity Radiated Field by Direct Current Injection using matrix methods based on Characteristic Mode Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1