An Improved Transformerless Grid-Connected PV System With Related Control Strategy to Reduce Leakage Current, Extract Maximum Power Point and Control Power

T. Ahmadzadeh, E. Babaei, M. Sabahi, T. Abedinzadeh
{"title":"An Improved Transformerless Grid-Connected PV System With Related Control Strategy to Reduce Leakage Current, Extract Maximum Power Point and Control Power","authors":"T. Ahmadzadeh, E. Babaei, M. Sabahi, T. Abedinzadeh","doi":"10.22068/IJEEE.16.4.513","DOIUrl":null,"url":null,"abstract":"The main purposes of a transformerless grid-connected photovoltaic (PV) system consist of the reduction of leakage current, extraction of maximum power point (MPP), tracking of MPP (MPPT), controlling the active and reactive powers, and having the unity power factor. To achieve the above-mentioned aims, the following actions have been performed in this paper. First of all, a brief analysis of the transformerless PV system has been done by using the conventional full-bridge (FB) topologies with two bipolar and unipolar PWM techniques. Then, an effective solution has been also introduced to significantly reduce the leakage current in the conventional H5 FB topology. Moreover, a proper control method has been proposed by using the combination of the fractional opencircuit voltage (FOCV) and the model predictive control (MPC) strategies to extract the MPP from PV panels, control the injection of the reactive power to the gird and have the unity power factor. At last, the simulation results performed in PSCAD software will be used to prove the correct performance of the proposed control method in the improved H5 FB topology.","PeriodicalId":39055,"journal":{"name":"Iranian Journal of Electrical and Electronic Engineering","volume":"16 1","pages":"513-523"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Electrical and Electronic Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22068/IJEEE.16.4.513","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
引用次数: 3

Abstract

The main purposes of a transformerless grid-connected photovoltaic (PV) system consist of the reduction of leakage current, extraction of maximum power point (MPP), tracking of MPP (MPPT), controlling the active and reactive powers, and having the unity power factor. To achieve the above-mentioned aims, the following actions have been performed in this paper. First of all, a brief analysis of the transformerless PV system has been done by using the conventional full-bridge (FB) topologies with two bipolar and unipolar PWM techniques. Then, an effective solution has been also introduced to significantly reduce the leakage current in the conventional H5 FB topology. Moreover, a proper control method has been proposed by using the combination of the fractional opencircuit voltage (FOCV) and the model predictive control (MPC) strategies to extract the MPP from PV panels, control the injection of the reactive power to the gird and have the unity power factor. At last, the simulation results performed in PSCAD software will be used to prove the correct performance of the proposed control method in the improved H5 FB topology.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种改进的无变压器并网光伏系统及其控制策略以降低漏电流、提取最大功率点和控制功率
无变压器光伏并网系统的主要目的是减小漏电、提取最大功率点、跟踪最大功率点、控制有功功率和无功功率、具有统一的功率因数。为了达到上述目的,本文进行了以下工作。首先,通过使用传统的全桥(FB)拓扑和双极和单极PWM技术对无变压器光伏系统进行了简要分析。然后,还介绍了一种有效的解决方案,可以显着降低传统H5 FB拓扑中的泄漏电流。在此基础上,提出了一种将分数电压(FOCV)与模型预测控制(MPC)相结合的控制方法,从光伏板中提取MPP,控制向电网的无功功率注入,并具有统一的功率因数。最后,在PSCAD软件中进行的仿真结果将用于证明所提出的控制方法在改进的H5 FB拓扑中的正确性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iranian Journal of Electrical and Electronic Engineering
Iranian Journal of Electrical and Electronic Engineering Engineering-Electrical and Electronic Engineering
CiteScore
1.70
自引率
0.00%
发文量
13
审稿时长
12 weeks
期刊最新文献
Robust Operation Planning With Participation of Flexibility Resources Both on Generation and Demand Sides Under Uncertainty of Wind-based Generation Units A Novel Droop-based Control Strategy for Improving the Performance of VSC-MTDC Systems in Post-Contingency Conditions Securing Reliability Constrained Technology Combination for Isolated Micro-Grid Using Multi-Agent Based Optimization View-Invariant and Robust Gait Recognition Using Gait Energy Images of Leg Region and Masking Altered Sections Multiple Electricity Markets Competitiveness Undergoing Symmetric and Asymmetric Renewables Development Policies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1