Evaluation of cardiac electromechanics in patients with newly diagnosed hypertension.

IF 1.2 4区 医学 Q4 PERIPHERAL VASCULAR DISEASE Blood Pressure Monitoring Pub Date : 2023-12-01 Epub Date: 2023-08-03 DOI:10.1097/MBP.0000000000000667
Timor Omar, Şerif Hamideyin, Muammer Karakayali, İnanç Artaç, Yavuz Karabağ, Cihan Dündar, İbrahim Rencüzoğullari
{"title":"Evaluation of cardiac electromechanics in patients with newly diagnosed hypertension.","authors":"Timor Omar,&nbsp;Şerif Hamideyin,&nbsp;Muammer Karakayali,&nbsp;İnanç Artaç,&nbsp;Yavuz Karabağ,&nbsp;Cihan Dündar,&nbsp;İbrahim Rencüzoğullari","doi":"10.1097/MBP.0000000000000667","DOIUrl":null,"url":null,"abstract":"Objectives: This study aimed to investigate the relationship between subclinical left ventricular (LV) systolic dysfunction and ECG parameters in newly diagnosed hypertension patients. Methods: In this cross-sectional study, adults diagnosed with hypertension based on 24-h ambulatory blood pressure monitor recordings were included. The patients were classified into two groups based on the presence of subclinical LV systolic dysfunction according to LV global longitudinal strain (LVGLS). Findings were compared between the two groups. Results: A total of 244 patients (female, 55.7%) were included. Based on LVGLS, 82 (33.6%) patients had subclinical LV systolic dysfunction. The proportion of early repolarization pattern (ERP) on ECG was significantly higher in patients with subclinical LV systolic dysfunction than in patients with normal LV systolic function [24 (28.6%) vs. 8 (5%), P < 0.001]. PR and corrected QT intervals were also significantly longer in patients with subclinical LV systolic dysfunction than in patients with normal LV systolic function [median (interquartile range), 148 (132–158) vs. 141 (127–152), P = 0.036 and 443 (427–459) vs. 431 (411–455), P = 0.007, respectively]. According to multivariate regression analysis ERP, early (E) wave velocity/late (A) wave velocity (E/A), and LV mass index were independently associated with subclinical LV systolic dysfunction. Conclusion: In newly diagnosed hypertension patients, the ERP on admission ECG could be a sign of subclinical systolic dysfunction.","PeriodicalId":8950,"journal":{"name":"Blood Pressure Monitoring","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000667","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/3 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study aimed to investigate the relationship between subclinical left ventricular (LV) systolic dysfunction and ECG parameters in newly diagnosed hypertension patients. Methods: In this cross-sectional study, adults diagnosed with hypertension based on 24-h ambulatory blood pressure monitor recordings were included. The patients were classified into two groups based on the presence of subclinical LV systolic dysfunction according to LV global longitudinal strain (LVGLS). Findings were compared between the two groups. Results: A total of 244 patients (female, 55.7%) were included. Based on LVGLS, 82 (33.6%) patients had subclinical LV systolic dysfunction. The proportion of early repolarization pattern (ERP) on ECG was significantly higher in patients with subclinical LV systolic dysfunction than in patients with normal LV systolic function [24 (28.6%) vs. 8 (5%), P < 0.001]. PR and corrected QT intervals were also significantly longer in patients with subclinical LV systolic dysfunction than in patients with normal LV systolic function [median (interquartile range), 148 (132–158) vs. 141 (127–152), P = 0.036 and 443 (427–459) vs. 431 (411–455), P = 0.007, respectively]. According to multivariate regression analysis ERP, early (E) wave velocity/late (A) wave velocity (E/A), and LV mass index were independently associated with subclinical LV systolic dysfunction. Conclusion: In newly diagnosed hypertension patients, the ERP on admission ECG could be a sign of subclinical systolic dysfunction.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新诊断高血压患者的心脏生物力学评价
本研究旨在探讨新诊断高血压患者亚临床左心室收缩功能障碍与心电图参数之间的关系。在这项横断面研究中,纳入了根据24小时动态血压监测记录诊断为高血压的成年人。根据左心室整体纵向应变(LVGLS),根据亚临床左心室收缩功能障碍的存在将患者分为两组。比较两组的研究结果。共纳入244名患者(女性,55.7%)。根据LVGLS,82名(33.6%)患者存在亚临床左心室收缩功能障碍。亚临床左心室收缩功能障碍患者心电图上早期复极模式(ERP)的比例显著高于左心室收缩功能正常的患者[24(28.6%)vs.8(5%),P < 亚临床左心室收缩功能障碍患者的PR和校正QT间期也明显长于左心室收缩功能正常患者[中位数(四分位间距),148(132-158)vs.141(127-152),P = 0.036和443(427–459)对431(411–455),P = 0.007)。根据多元回归分析ERP,早期(E)波速度/晚期(A)波速度(E/A)和左心室质量指数与亚临床左心室收缩功能障碍独立相关。在新诊断的高血压患者中,入院心电图上的ERP可能是亚临床收缩功能障碍的标志。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Blood Pressure Monitoring
Blood Pressure Monitoring 医学-外周血管病
CiteScore
2.00
自引率
7.70%
发文量
110
审稿时长
>12 weeks
期刊介绍: Blood Pressure Monitoring is devoted to original research in blood pressure measurement and blood pressure variability. It includes device technology, analytical methodology of blood pressure over time and its variability, clinical trials - including, but not limited to, pharmacology - involving blood pressure monitoring, blood pressure reactivity, patient evaluation, and outcomes and effectiveness research. This innovative journal contains papers dealing with all aspects of manual, automated, and ambulatory monitoring. Basic and clinical science papers are considered although the emphasis is on clinical medicine. Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.
期刊最新文献
Does greater adherence to a healthy dietary pattern correspond to a better body composition and cardiorespiratory fitness in adults with overweight and primary hypertension? Data from the EXERDIET-HTA study. Validation of the TMB-2296-BT blood pressure monitor in adults according to the ISO 81060-2:2018 + Amd.1:2020. Inflammation-based markers, especially the uric acid/albumin ratio, are associated with non-dipper pattern in newly diagnosed treatment-naive hypertensive patients. Validating the accuracy of Omron HEM-7372T1-AZAZ (BP5460) in monitoring blood pressure according to the ISO 81060-2:2018+Amd 1:2020 protocol in the general population. Blood pressure variability at rest and during pressor challenges in patients with acute ischemic stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1