{"title":"KNEE ARTHRODESIS WITH COMPUTER-ASSISTED EXTERNAL FIXATOR SYSTEM AFTER PROSTHETIC JOINT INFECTION FOR ELDERLY POPULATION","authors":"M. Kanar, N. Cam","doi":"10.29400/tjgeri.2023.331","DOIUrl":null,"url":null,"abstract":"Introduction: This study aimed to evaluate the effectiveness of a computer-assisted circular external fixator used to achieve arthrodesis in elderly patients with failed infected total knee arthroplasty. Materials and Methods: Retrospectively 11 patients who treated with arthrodesis between 2015 and 2020 were included in the study. The average age was 73.5 ±4.73 years (65–81). All patients had recurrent infections after total knee arthroplasty. Radiologic evaluations, the time for fusion, shortening of extremities, visual analog scale scores, Oxford knee scoring system, lower extremity functional scale of all patients were compared pre-and post-operatively. complications of the technique were noted. Results: The mean follow-up was 33.7 ±12.85 (12–52) months. Fusion was achieved in all patients. The average limb length discrepancy after removal of the fixator was 46±0.78 (36–61) mm. The mean visual analog scale score measured pre-op was 6.91±0.94 (5–8), and after fixator removal they were measured as 2.36±0.92 (1–4). The mean Oxford knee score was 10.27±2.68 (4–14) pre-operatively and 28.64±2.69 (23–32) postoperatively. The mean, lower extremity functional scale was 17.06±9.38 (7.5–33.8) pre-operatively and 38.54±12.22 (21.3–56.3) postoperatively. No joint infection recurrence was seen post-operatively. Conclusion: Arthrodesis is a suitable option for elderly patients with limited mobilization who are tired of repeated revision surgeries. Due to its high fusion and low complication rate, computer-assisted circular external fixator is an effective method in the treatment of difficult knee arthrodesis required after infected total knee arthroplasty. Key Words: Arthroplasty, Replacement, Knee; Reoperation; Infection; Arthrodesis; External Fixators.","PeriodicalId":51196,"journal":{"name":"Turkish Journal of Geriatrics-Turk Geriatri Dergisi","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Geriatrics-Turk Geriatri Dergisi","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.29400/tjgeri.2023.331","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GERIATRICS & GERONTOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: This study aimed to evaluate the effectiveness of a computer-assisted circular external fixator used to achieve arthrodesis in elderly patients with failed infected total knee arthroplasty. Materials and Methods: Retrospectively 11 patients who treated with arthrodesis between 2015 and 2020 were included in the study. The average age was 73.5 ±4.73 years (65–81). All patients had recurrent infections after total knee arthroplasty. Radiologic evaluations, the time for fusion, shortening of extremities, visual analog scale scores, Oxford knee scoring system, lower extremity functional scale of all patients were compared pre-and post-operatively. complications of the technique were noted. Results: The mean follow-up was 33.7 ±12.85 (12–52) months. Fusion was achieved in all patients. The average limb length discrepancy after removal of the fixator was 46±0.78 (36–61) mm. The mean visual analog scale score measured pre-op was 6.91±0.94 (5–8), and after fixator removal they were measured as 2.36±0.92 (1–4). The mean Oxford knee score was 10.27±2.68 (4–14) pre-operatively and 28.64±2.69 (23–32) postoperatively. The mean, lower extremity functional scale was 17.06±9.38 (7.5–33.8) pre-operatively and 38.54±12.22 (21.3–56.3) postoperatively. No joint infection recurrence was seen post-operatively. Conclusion: Arthrodesis is a suitable option for elderly patients with limited mobilization who are tired of repeated revision surgeries. Due to its high fusion and low complication rate, computer-assisted circular external fixator is an effective method in the treatment of difficult knee arthrodesis required after infected total knee arthroplasty. Key Words: Arthroplasty, Replacement, Knee; Reoperation; Infection; Arthrodesis; External Fixators.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
老年人群假体关节感染后计算机辅助外固定系统膝关节置换术
引言:本研究旨在评估计算机辅助圆形外固定器用于老年感染性全膝关节置换术失败患者关节融合术的有效性。材料和方法:回顾性分析2015年至2020年间接受关节融合术治疗的11名患者。平均年龄73.5±4.73岁(65-81岁)。所有患者在全膝关节置换术后均有复发性感染。术前和术后比较所有患者的放射学评估、融合时间、四肢缩短、视觉模拟量表评分、牛津膝关节评分系统、下肢功能量表。注意到该技术的并发症。结果:平均随访时间为33.7±12.85(12-52)个月。所有患者均实现融合。移除固定器后的平均肢体长度差异为46±0.78(36-61)mm。术前测量的平均视觉模拟量表得分为6.91±0.94(5-8),移除固定器之后测量的平均视力模拟量表评分为2.36±0.92(1-4)。Oxford膝关节平均得分术前为10.27±2.68(4-14),术后为28.64±2.69(23-32)。术前平均下肢功能量表为17.06±9.38(7.5–33.8),术后平均为38.54±12.22(21.3–56.3)。术后未发现关节感染复发。结论:关节固定术是一种适合于活动受限、厌倦重复翻修手术的老年患者的选择。计算机辅助环形外固定器具有融合率高、并发症发生率低的特点,是治疗感染性全膝关节置换术后难治性膝关节融合术的有效方法。关键词:关节成形术,置换术,膝关节;重新操作;传染关节固定术;外部固定器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
46
审稿时长
6-12 weeks
期刊介绍: Turkish Journal of Geriatrics is a peer-reviewed journal. Official language of the journal is English. Turkish Journal of Geriatrics invites submission of Original Articles based on clinical and laboratory studies. Review Articles are published only after the invitation from the Editorial Board.
期刊最新文献
Relationship Between Different Nutritional Scores in Elderly Patients with Acute Decompensated Heart Failure in the Coronary Intensive Care Unit Comparison of breast cancer patients over the age of 70 and under the age of 35 COVID-19 Vaccine Refusal and Associated Factors: A Population-Based Descriptive Study A Single-Center, Cross-Sectional Prevalence Study of Cervical Diffuse Idiopathic Skeletal Hyperostosis Factors affecting drug interactions and their clinical importance in geriatric outpatients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1