Assessment of Potential Thrombogenicity in an Animal Model of a Triple Viral Inactivated Factor IX Concentrate Manufactured in Argentina

Martínez-Toldos Mc, R. Rodriguez, A. Marinsaldi, Rodriguez Gr, H. Guglielmone, M. E. Bernardi, A. Valdomero, G. Cuadra
{"title":"Assessment of Potential Thrombogenicity in an Animal Model of a Triple Viral Inactivated Factor IX Concentrate Manufactured in Argentina","authors":"Martínez-Toldos Mc, R. Rodriguez, A. Marinsaldi, Rodriguez Gr, H. Guglielmone, M. E. Bernardi, A. Valdomero, G. Cuadra","doi":"10.26420/ANNHEMATOLONCOL.2021.1343","DOIUrl":null,"url":null,"abstract":"The risk of thromboembolism with FIX replacement therapy remains a concern for hemophilic B patients. Previous studies from our laboratory demonstrated that the activated factor content of the FIX Plasma Derived (FIXpd) manufactured at UNC-Hemoderivados was negligible by in vitro assay. Despite this, we considered it important to conduct studies to assess the potential thrombogenic risk of our FIXpd concentrates using a modified stasis animal model. FIXpd were inject doses of 100 or 200 IU F IX kg-1 and some samples were supplemented with heparin (<0.5 of heparin/ IU FIX). Eight rats were tested at each dose level in the presence or absence of heparin, considering those samples with a thrombogenicity ≥2.0 as of potential thrombogenic risk. The mean scores ± SD 100 and 200 IU kg-1 in the presence or absence of heparin were 0.25±0.06 and 2.25±0.45 and 1.19±0.26 and 2.81±0.40, respectively. At both doses tested of FIXpd in the absence of heparin, there was no significant difference in mean scores (P<0.05). The encouraging data obtained from these animal experiments and results from in vitro tests, support the low thrombotic risk associated with the FIXpd concentrate manufactured in UNC Hemoderivados.","PeriodicalId":72219,"journal":{"name":"Annals of hematology & oncology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of hematology & oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26420/ANNHEMATOLONCOL.2021.1343","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The risk of thromboembolism with FIX replacement therapy remains a concern for hemophilic B patients. Previous studies from our laboratory demonstrated that the activated factor content of the FIX Plasma Derived (FIXpd) manufactured at UNC-Hemoderivados was negligible by in vitro assay. Despite this, we considered it important to conduct studies to assess the potential thrombogenic risk of our FIXpd concentrates using a modified stasis animal model. FIXpd were inject doses of 100 or 200 IU F IX kg-1 and some samples were supplemented with heparin (<0.5 of heparin/ IU FIX). Eight rats were tested at each dose level in the presence or absence of heparin, considering those samples with a thrombogenicity ≥2.0 as of potential thrombogenic risk. The mean scores ± SD 100 and 200 IU kg-1 in the presence or absence of heparin were 0.25±0.06 and 2.25±0.45 and 1.19±0.26 and 2.81±0.40, respectively. At both doses tested of FIXpd in the absence of heparin, there was no significant difference in mean scores (P<0.05). The encouraging data obtained from these animal experiments and results from in vitro tests, support the low thrombotic risk associated with the FIXpd concentrate manufactured in UNC Hemoderivados.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
阿根廷生产的三重病毒灭活因子IX浓缩物动物模型的潜在血栓形成性评估
FIX替代疗法的血栓栓塞风险仍然是血友病B患者关注的问题。我们实验室之前的研究表明,通过体外检测,unc - hemderivatives公司生产的FIX血浆衍生(FIXpd)的活化因子含量可以忽略不计。尽管如此,我们认为有必要利用改良的停滞动物模型进行研究,评估FIXpd浓缩物的潜在血栓形成风险。FIXpd注射剂量为100或200 IU FIX kg-1,部分样品添加肝素(<0.5肝素/ IU FIX)。8只大鼠在肝素存在或不存在的情况下,在每个剂量水平下进行测试,考虑到这些样品的血栓形成性≥2.0作为潜在的血栓形成风险。肝素存在或不存在时的平均评分±SD 100和200 IU kg-1分别为0.25±0.06和2.25±0.45和1.19±0.26和2.81±0.40。在没有肝素的情况下,两种剂量的FIXpd测试,平均评分无显著差异(P<0.05)。从这些动物实验中获得的令人鼓舞的数据和体外试验的结果,支持与UNC血液衍生物制造的FIXpd浓缩物相关的低血栓形成风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
MGMT Methylated High Grade Glioma with Distant Recurrence and Stable Original Tumor Site: Case Series. Isolated Bone Marrow Mastocytosis may be Associated with Reduced Overall Survival Combination Venetoclax and Rituximab: A Novel Approach to Gastrointestinal Hemorrhage from Acquired Von Willebrand Syndrome in the Setting of Relapsed Chronic Lymphocytic Leukemia Basophils Unchained: A Rare Form of Leukemia Surge in Procalcitonin Levels Post ATG During Stem Cell Transplantation for Aplastic Anemia: A Diagnostic Dilemma with Sepsis?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1