Spatial infection control in burn center organization: a burn center design experience for evidence-based architecture

IF 1.6 Q3 MANAGEMENT Facilities Pub Date : 2023-04-28 DOI:10.1108/f-05-2022-0066
Yelda Durgun Şahin, Osman Metin Yavuz, E. Kesiktaş
{"title":"Spatial infection control in burn center organization: a burn center design experience for evidence-based architecture","authors":"Yelda Durgun Şahin, Osman Metin Yavuz, E. Kesiktaş","doi":"10.1108/f-05-2022-0066","DOIUrl":null,"url":null,"abstract":"\nPurpose\nThis study discusses that the necessary criteria and the solution approach taken to resolve the main spatial infection problems with a burn center design should be evaluated holistically to achieve spatial infection control in a burn center. The burn center design plays an important role in protecting severely burned patients from infection because the microbial flora of the hospital can affect the infection risk. In hospitals, sterilization and disinfection are the basic components of infection prevention; however, the prevention and control of infection for burn patients also requires the design of burn centers that adhere to a specific set of criteria that considers spatial infection control in addition to appropriate burn treatment methods and treatments. In this study, a burn facility converted from a burn unit into a burn center is introduced and the necessary design inputs for the transformation are discussed because there is no holistic study in the literature that delas with all the spaces that should be in a burn center and relations between spaces. This study aims to define the functional relations between each of the units and the spaces that change according to different sterilization demands in the burn center for ensuring spatial infection control. Furthermore, it aims to propose a method for ensuring continuity in the control of spatial infections.\n\n\nDesign/methodology/approach\nThe burn care and health facilities guidelines are examined within the framework of spatial standards, together with a comprehensive literature review. The design method was based on the spread of microorganisms and the effect of human movement on space and spatial transitions in the burn center, according to all relevant literature reviews. To determine the extent to which the differences in treatment protocols of burn care guidelines were reflected in the space, interviews were conducted with burn facility officials. The plan–do–check–act (PDCA) method is also modeled to ensure the continuity of infection control in the burn center.\n\n\nFindings\nThe burn center design findings are classified under three main headings, namely, location of the burn center in the hospital, spatial organization and physical features of the burn center and the air flowing system. The importance of the interactions among the criteria for spatial infection control has been revealed. Due to the physical space characteristics and air flow characteristics that change according to human movement and the way microorganisms spread, it has been seen that designing the air flow and architectural aspects together has an effective role in providing spatial infection control. Accordingly, a functional relation scheme for the center has been suggested. It is also proposed as a model to ensure the continuity of infection control in the burn center.\n\n\nPractical implications\nThis research presents spatial measures for infection control in burn centers for practitioners in health-care settings such as designers, engineers, doctors and nurses. The PDCA method also leads to continuity of infection control for hospital management.\n\n\nOriginality/value\nThis is the first study, to the best of the authors’ knowledge, to focus on developing the criteria for spatial infection control in burn center. Moreover, the aim is to create a function chart that encompasses the relationships between the units within the burn center design so that infection control can be coordinated spatially.\n","PeriodicalId":47595,"journal":{"name":"Facilities","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2023-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Facilities","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/f-05-2022-0066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MANAGEMENT","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose This study discusses that the necessary criteria and the solution approach taken to resolve the main spatial infection problems with a burn center design should be evaluated holistically to achieve spatial infection control in a burn center. The burn center design plays an important role in protecting severely burned patients from infection because the microbial flora of the hospital can affect the infection risk. In hospitals, sterilization and disinfection are the basic components of infection prevention; however, the prevention and control of infection for burn patients also requires the design of burn centers that adhere to a specific set of criteria that considers spatial infection control in addition to appropriate burn treatment methods and treatments. In this study, a burn facility converted from a burn unit into a burn center is introduced and the necessary design inputs for the transformation are discussed because there is no holistic study in the literature that delas with all the spaces that should be in a burn center and relations between spaces. This study aims to define the functional relations between each of the units and the spaces that change according to different sterilization demands in the burn center for ensuring spatial infection control. Furthermore, it aims to propose a method for ensuring continuity in the control of spatial infections. Design/methodology/approach The burn care and health facilities guidelines are examined within the framework of spatial standards, together with a comprehensive literature review. The design method was based on the spread of microorganisms and the effect of human movement on space and spatial transitions in the burn center, according to all relevant literature reviews. To determine the extent to which the differences in treatment protocols of burn care guidelines were reflected in the space, interviews were conducted with burn facility officials. The plan–do–check–act (PDCA) method is also modeled to ensure the continuity of infection control in the burn center. Findings The burn center design findings are classified under three main headings, namely, location of the burn center in the hospital, spatial organization and physical features of the burn center and the air flowing system. The importance of the interactions among the criteria for spatial infection control has been revealed. Due to the physical space characteristics and air flow characteristics that change according to human movement and the way microorganisms spread, it has been seen that designing the air flow and architectural aspects together has an effective role in providing spatial infection control. Accordingly, a functional relation scheme for the center has been suggested. It is also proposed as a model to ensure the continuity of infection control in the burn center. Practical implications This research presents spatial measures for infection control in burn centers for practitioners in health-care settings such as designers, engineers, doctors and nurses. The PDCA method also leads to continuity of infection control for hospital management. Originality/value This is the first study, to the best of the authors’ knowledge, to focus on developing the criteria for spatial infection control in burn center. Moreover, the aim is to create a function chart that encompasses the relationships between the units within the burn center design so that infection control can be coordinated spatially.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
烧伤中心组织的空间感染控制:循证建筑的烧伤中心设计经验
目的探讨烧伤中心设计中解决主要空间感染问题的必要标准和解决方法,以实现烧伤中心的空间感染控制。烧伤中心的设计在保护严重烧伤患者免受感染方面起着重要的作用,因为医院的微生物菌群会影响感染的风险。在医院,灭菌和消毒是预防感染的基本组成部分;然而,预防和控制烧伤患者的感染也需要烧伤中心的设计坚持一套特定的标准,除了考虑适当的烧伤治疗方法和治疗外,还要考虑空间感染控制。在本研究中,介绍了一个从烧伤单元到烧伤中心的烧伤设施,并讨论了改造所需的设计输入,因为文献中没有全面的研究,涉及烧伤中心应有的所有空间以及空间之间的关系。本研究旨在定义烧伤中心每个单元与空间之间的功能关系,这些功能关系根据不同的消毒需求而变化,以确保空间感染控制。此外,它旨在提出一种确保空间感染控制连续性的方法。设计/方法/方法烧伤护理和卫生设施指南在空间标准框架内进行审查,并进行全面的文献综述。根据所有相关文献综述,设计方法基于微生物的传播和人体运动对烧伤中心空间和空间过渡的影响。为了确定烧伤护理指南治疗方案的差异在多大程度上反映在空间中,对烧伤设施官员进行了采访。为了保证烧伤中心感染控制的连续性,还建立了计划-执行-检查-行动(PDCA)方法模型。烧伤中心的设计结果分为三个主要标题,即医院烧伤中心的位置,烧伤中心的空间组织和物理特征以及空气流动系统。揭示了各指标间相互作用对空间感染控制的重要性。由于物理空间特征和气流特征会随着人类运动和微生物传播的方式而变化,因此已经看到气流和建筑方面的设计在提供空间感染控制方面具有有效的作用。据此,提出了中心的功能关系方案。并提出作为一种模式,以确保在烧伤中心感染控制的连续性。实际意义本研究提出烧伤中心感染控制的空间措施,适用于卫生保健机构的从业人员,如设计师、工程师、医生和护士。PDCA方法还为医院管理带来了感染控制的连续性。原创性/价值据作者所知,这是第一次针对烧伤中心空间感染控制标准的研究。此外,目的是创建一个功能图表,包括烧伤中心设计中各单元之间的关系,以便在空间上协调感染控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Facilities
Facilities MANAGEMENT-
CiteScore
4.40
自引率
17.40%
发文量
46
期刊介绍: The journal offers thorough, independent and expert papers to inform relevant audiences of thinking and practice in the field, including topics such as: ■Intelligent buildings ■Post-occupancy evaluation (building evaluation) ■Relocation and change management ■Sick building syndrome ■Ergonomics and workplace design ■Environmental and workplace psychology ■Briefing, design and construction ■Energy consumption ■Quality initiatives ■Infrastructure management
期刊最新文献
Facility network design by using k-mean and elbow method: a case of Indian handloom industry Investigating the role of path architecture complexity in users’ movement patterns in hospital circulation systems: case studies in Golestan, Iran Students with disabilities (SWDs) and facilities accessibility in a northern Nigerian public university: dismantling exclusion in achieving SDG4 Students’ support facilities and academic adjustment among first-year undergraduates: evidence from a Nigerian public university Barriers to the adoption of energy management systems in residential buildings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1