Water-soluble inorganic ions of size-differentiated atmospheric particles from a suburban site of Mexico City

IF 3 4区 地球科学 Q2 ENVIRONMENTAL SCIENCES Journal of Atmospheric Chemistry Pub Date : 2017-08-21 DOI:10.1007/s10874-017-9369-5
Telma Castro, Oscar Peralta, Dara Salcedo, José Santos, María I. Saavedra, María L. Espinoza, Alejandro Salcido, Ana-Teresa Celada-Murillo, Susana Carreón-Sierra, Harry Álvarez-Ospina, Giovanni Carabali, Valter Barrera, Sasha Madronich
{"title":"Water-soluble inorganic ions of size-differentiated atmospheric particles from a suburban site of Mexico City","authors":"Telma Castro,&nbsp;Oscar Peralta,&nbsp;Dara Salcedo,&nbsp;José Santos,&nbsp;María I. Saavedra,&nbsp;María L. Espinoza,&nbsp;Alejandro Salcido,&nbsp;Ana-Teresa Celada-Murillo,&nbsp;Susana Carreón-Sierra,&nbsp;Harry Álvarez-Ospina,&nbsp;Giovanni Carabali,&nbsp;Valter Barrera,&nbsp;Sasha Madronich","doi":"10.1007/s10874-017-9369-5","DOIUrl":null,"url":null,"abstract":"<p>During the MILAGRO campaign, March 2006, eight-stage cut impactors were used to sample atmospheric particles at Tecámac (T1 supersite), towards the northeast edge of the Mexico City Metropolitan Area, collecting fresh local emissions and aged pollutants produced in Mexico City. Particle samples were analyzed to determine total mass concentrations of Ca<sup>2+</sup>, Mg<sup>2+</sup>, NH<sub>4</sub>\n <sup>+</sup>, K<sup>+</sup>, Cl<sup>?</sup>, SO<sub>4</sub>\n <sup>2?</sup>, and NO<sub>3</sub>\n <sup>?</sup>. Average concentrations were 22.1?±?7.2?μg m<sup>?3</sup> for PM<sub>10</sub> and 18.3?±?6.2?μg m<sup>?3</sup> for PM<sub>1.8</sub>. A good correlation between PM<sub>10</sub> and PM<sub>1.8</sub>, without influence from wind patterns, indicates that local emissions are more important than the city’s pollution transported to the site, despite the fact that Tecámac is just 40?km away from Mexico City. A lack of diurnal patterns in the PM<sub>2.5</sub>/PM<sub>1.8</sub> ratio supports this conclusion. The inorganic composition of particles suggests that vehicles, soil resuspension, and industries are the main pollutant sources. Finally, the particles were found to be neutralized, in agreement with observations in the Mexico City Metropolitan Area.</p>","PeriodicalId":611,"journal":{"name":"Journal of Atmospheric Chemistry","volume":"75 2","pages":"155 - 169"},"PeriodicalIF":3.0000,"publicationDate":"2017-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s10874-017-9369-5","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Atmospheric Chemistry","FirstCategoryId":"89","ListUrlMain":"https://link.springer.com/article/10.1007/s10874-017-9369-5","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 7

Abstract

During the MILAGRO campaign, March 2006, eight-stage cut impactors were used to sample atmospheric particles at Tecámac (T1 supersite), towards the northeast edge of the Mexico City Metropolitan Area, collecting fresh local emissions and aged pollutants produced in Mexico City. Particle samples were analyzed to determine total mass concentrations of Ca2+, Mg2+, NH4 +, K+, Cl?, SO4 2?, and NO3 ?. Average concentrations were 22.1?±?7.2?μg m?3 for PM10 and 18.3?±?6.2?μg m?3 for PM1.8. A good correlation between PM10 and PM1.8, without influence from wind patterns, indicates that local emissions are more important than the city’s pollution transported to the site, despite the fact that Tecámac is just 40?km away from Mexico City. A lack of diurnal patterns in the PM2.5/PM1.8 ratio supports this conclusion. The inorganic composition of particles suggests that vehicles, soil resuspension, and industries are the main pollutant sources. Finally, the particles were found to be neutralized, in agreement with observations in the Mexico City Metropolitan Area.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
墨西哥城郊区大气颗粒中大小不同的水溶性无机离子
在2006年3月的MILAGRO项目中,使用了8级切割撞击器对墨西哥城大都会区东北边缘的Tecámac (T1超级站点)的大气颗粒进行采样,收集墨西哥城当地排放的新鲜污染物和产生的陈旧污染物。对颗粒样品进行分析,测定Ca2+、Mg2+、NH4 +、K+、Cl?那么,42 ?和NO3 ?平均浓度为22.1±7.2?μg m ?PM10为18.3±6.2?μg m ?PM1.8为3。在不受风型影响的情况下,PM10和PM1.8之间的良好相关性表明,当地的排放比输送到现场的城市污染更重要,尽管Tecámac只有40?距离墨西哥城一公里。缺乏PM2.5/PM1.8比值的日模式支持这一结论。颗粒的无机组成表明,车辆、土壤再悬浮和工业是主要的污染源。最后,这些粒子被发现是中和的,这与墨西哥城大都市区的观测结果一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Atmospheric Chemistry
Journal of Atmospheric Chemistry 地学-环境科学
CiteScore
4.60
自引率
5.00%
发文量
16
审稿时长
7.5 months
期刊介绍: The Journal of Atmospheric Chemistry is devoted to the study of the chemistry of the Earth''s atmosphere, the emphasis being laid on the region below about 100 km. The strongly interdisciplinary nature of atmospheric chemistry means that it embraces a great variety of sciences, but the journal concentrates on the following topics: Observational, interpretative and modelling studies of the composition of air and precipitation and the physiochemical processes in the Earth''s atmosphere, excluding air pollution problems of local importance only. The role of the atmosphere in biogeochemical cycles; the chemical interaction of the oceans, land surface and biosphere with the atmosphere. Laboratory studies of the mechanics in homogeneous and heterogeneous transformation processes in the atmosphere. Descriptions of major advances in instrumentation developed for the measurement of atmospheric composition and chemical properties.
期刊最新文献
Association between time of day and carbonaceous PM2.5 and oxidative potential in summer and winter in the Suncheon industrial area, Republic of Korea PM2.5 and PM10-related carcinogenic and non-carcinogenic risk assessment in Iran Characteristics of surface air quality over provincial capital cities in Northwestern China during 2013–2020 Stable isotopic, bulk, and molecular compositions of post-monsoon biomass-burning aerosols in Delhi suggest photochemical ageing during regional transport is more pronounced than local processing A review on sequential extraction of metals bound particulate matter and their health risk assessment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1