Innovative Differential Magnetic Localization Method for Capsule Endoscopy to Prevent Interference Caused by the Geomagnetic Field

IF 0.6 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Advances in Radio Science Pub Date : 2021-04-08 DOI:10.36227/TECHRXIV.14346179.V1
S. Zeising, D. Anzai, A. Thalmayer, Georg Fischer, J. Kirchner
{"title":"Innovative Differential Magnetic Localization Method for Capsule Endoscopy to Prevent Interference Caused by the Geomagnetic Field","authors":"S. Zeising, D. Anzai, A. Thalmayer, Georg Fischer, J. Kirchner","doi":"10.36227/TECHRXIV.14346179.V1","DOIUrl":null,"url":null,"abstract":"Wireless capsule endoscopy is an established medical application for the examination of the gastrointestinal tract. However, the robust and precise localization of these capsules is still in need of further scientific investigation. This paper presents an innovative differential magnetic localization method for capsule endoscopy to prevent interference caused by the geomagnetic field. The effect of changing the orientation of the capsule on the localization process was also examined. Simulations using COMSOL Multiphysics with the superimposed geomagnetic field were performed. The Levenberg–Marquardt algorithm was applied in MATLAB to estimate the position and orientation of the capsule. Comparing the proposed differential method with the absolute magnetic localization method under ideal conditions, the mean position and orientation errors were reduced by three orders in magnitude to less than 0.1 mm and 0.1 ° respectively. Even if sensor non-idealities are considered, the simulationbased results reveal that our proposed method is competitive with state-of-the-art geomagnetic compensation methods for static magnetic localization of capsule endoscopes.The achieved localization accuracy by applying the differential method is not dependent on the rotation of the localization system relative to the geomagnetic flux density under the made assumptions and the impact of the magnet orientation is neglectable. It is concluded that the proposed method is capable of preventing all interference whose components are approximately equal at all sensors with identical orientation. \n","PeriodicalId":45093,"journal":{"name":"Advances in Radio Science","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2021-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Radio Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36227/TECHRXIV.14346179.V1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 5

Abstract

Wireless capsule endoscopy is an established medical application for the examination of the gastrointestinal tract. However, the robust and precise localization of these capsules is still in need of further scientific investigation. This paper presents an innovative differential magnetic localization method for capsule endoscopy to prevent interference caused by the geomagnetic field. The effect of changing the orientation of the capsule on the localization process was also examined. Simulations using COMSOL Multiphysics with the superimposed geomagnetic field were performed. The Levenberg–Marquardt algorithm was applied in MATLAB to estimate the position and orientation of the capsule. Comparing the proposed differential method with the absolute magnetic localization method under ideal conditions, the mean position and orientation errors were reduced by three orders in magnitude to less than 0.1 mm and 0.1 ° respectively. Even if sensor non-idealities are considered, the simulationbased results reveal that our proposed method is competitive with state-of-the-art geomagnetic compensation methods for static magnetic localization of capsule endoscopes.The achieved localization accuracy by applying the differential method is not dependent on the rotation of the localization system relative to the geomagnetic flux density under the made assumptions and the impact of the magnet orientation is neglectable. It is concluded that the proposed method is capable of preventing all interference whose components are approximately equal at all sensors with identical orientation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
创新的胶囊内窥镜差分磁定位方法防止地磁场干扰
无线胶囊内窥镜是一种用于胃肠道检查的既定医学应用。然而,这些胶囊的稳健和精确定位仍需要进一步的科学研究。本文提出了一种创新的胶囊内窥镜检查差分磁定位方法,以防止地磁场引起的干扰。还研究了改变胶囊方向对定位过程的影响。利用叠加地磁场的COMSOL Multiphysics进行了模拟。在MATLAB中应用Levenberg–Marquardt算法来估计胶囊的位置和方向。在理想条件下,将所提出的微分方法与绝对磁定位方法进行比较,平均位置和方位误差分别降低了三个数量级,小于0.1mm和0.1°。即使考虑了传感器的非理想性,基于模拟的结果表明,我们提出的方法在胶囊内窥镜的静磁定位方面与最先进的地磁补偿方法具有竞争力。在所做的假设下,通过应用微分方法实现的定位精度不取决于定位系统相对于地磁通密度的旋转,磁体取向的影响是可以忽略的。得出的结论是,所提出的方法能够防止在具有相同方向的所有传感器处分量近似相等的所有干扰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advances in Radio Science
Advances in Radio Science ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
0.90
自引率
0.00%
发文量
3
审稿时长
45 weeks
期刊最新文献
MmWave scattering properties of roads on rough asphalt and concrete surfaces Y-shaped tunable monolithic dual colour lasers for THz technology Egbert von Lepel and the Invention of the Spark-Gap Transmitter Long-term trends of midlatitude horizontal mesosphere/lower thermosphere winds over four decades Approximation of High Intensity Radiated Field by Direct Current Injection using matrix methods based on Characteristic Mode Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1