{"title":"Improving traverse redundancy and precision by running on double lines","authors":"A. C. Chukwuocha, Franklin Enyinnaya Onyeagoro","doi":"10.4314/SAJG.V7I3.13","DOIUrl":null,"url":null,"abstract":"Good redundancy is required to isolate gross errors and improve the qualities of derived parameters. Improving the weak redundancies of traditional traverses by traversing on double lines is now possible with total stations which provide for less cumbersome measurements than previously possible and more so now that control traverses are computed by least squares adjustment using readily available computer software. Traversing on double lines requires some care in choosing traverse stations with inter-visibility from two immediately preceding and two directly succeeding stations. Traverses were run on double lines resulting in redundancy increase of seven per station. Local accuracy precision parameters improved also by as much as 25% and 52% with implementation at 30% and 100% of the traverse stations respectively. A chart that may be used to determine percentage number of traverse stations where traversing on double lines would be implemented to achieve set local accuracy improvements is presented.","PeriodicalId":43854,"journal":{"name":"South African Journal of Geomatics","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2019-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4314/SAJG.V7I3.13","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"South African Journal of Geomatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/SAJG.V7I3.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"REMOTE SENSING","Score":null,"Total":0}
引用次数: 0

Abstract

Good redundancy is required to isolate gross errors and improve the qualities of derived parameters. Improving the weak redundancies of traditional traverses by traversing on double lines is now possible with total stations which provide for less cumbersome measurements than previously possible and more so now that control traverses are computed by least squares adjustment using readily available computer software. Traversing on double lines requires some care in choosing traverse stations with inter-visibility from two immediately preceding and two directly succeeding stations. Traverses were run on double lines resulting in redundancy increase of seven per station. Local accuracy precision parameters improved also by as much as 25% and 52% with implementation at 30% and 100% of the traverse stations respectively. A chart that may be used to determine percentage number of traverse stations where traversing on double lines would be implemented to achieve set local accuracy improvements is presented.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双线运行提高导线冗余度和精度
需要良好的冗余度来隔离粗误差并提高导出参数的质量。通过双线穿越来改善传统导线的弱冗余性,现在全站仪可以提供比以前更少麻烦的测量,现在更是如此,因为控制导线是使用现成的计算机软件通过最小二乘法调整来计算的。在双线上进行导线测量时,需要从两个紧挨在前的测站和两个直接在后的测站中选择具有通视性的导线测量测站。导线在双线上运行,导致每个站的冗余增加了7个。通过在30%和100%的导线站实施,局部精度精度参数也分别提高了25%和52%。给出了一个图表,该图表可用于确定在双线上进行导线测量以实现设定的局部精度改进的导线测量站的百分比数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
82
期刊最新文献
Classification of 3D Sonar Point Clouds derived Underwater using Machine and Deep Learning (CANUPO and RandLA-Net) Approaches Characterising the evolution of the urban form of zones that accommodate warehousing clusters in the City of Cape Town municipality Error Analysis in Multibeam Hydrographic Survey System Temporal Characterization of Land Use Change and Land-scape Processes in Informal Settlements in the City of Cape Town, South Africa Analysis of thermally-induced displacements of the HartRAO Lunar Laser Ranger optical tube: impact on pointing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1