GAMMA DOSE VALUES OF STRATIGRAPHIC UNITS SURFACED IN BEHRAMKALE (ÇANAKKALE) - ZEYTİNLİ (EDREMİT-BALIKESİR) SECTION OF KAZ MOUNTAINS

Z. Yümün, E. Kam, M. Önce
{"title":"GAMMA DOSE VALUES OF STRATIGRAPHIC UNITS SURFACED IN BEHRAMKALE (ÇANAKKALE) - ZEYTİNLİ (EDREMİT-BALIKESİR) SECTION OF KAZ MOUNTAINS","authors":"Z. Yümün, E. Kam, M. Önce","doi":"10.18596/jotcsa.565054","DOIUrl":null,"url":null,"abstract":"In this study, gamma dose values were measured in the study area around a distance of 60 kmparallel to the Aegean Sea in Gure, Kucukkuyu and Kazdagi regions. In the study, gamma dose values were measured at 25 locations that best represent the area. These measurements were made by keeping the portable Eberline Smart Portable (ESP) scintillator detector constant at a height of 1 meter above ground level. A SPA-6 plastic scintillation sensor isconnected to the instrument tip to perform the measurement. These devices are direct measurement of external radiation. As the measurements were carried out in the open area,0.2 occupancy factor was used in the calculations. In the studies, the highest effective dose value was calculated as 0.3 mSv at the location 2 (Asos Kadirga Bay). The lowest effective dose value is 0.054 mSV at the 15th location (Avcilar Village Mountain slope) and the average annual gamma dose is 0.14 mSv. For the study area, when the lifetime risk of cancer was calculated using gamma effective dose values, it was determined at the highest 2 locations (1,2x10-3) and the lowest at the 15locations (0,21x10-3). The average lifetime cancer risk value (2,39x10 -4 ) of Turkey, were compared with values calculated in this study. In this comparison, the values of locations 9 and 15 were lower and the values of other locations were higher.","PeriodicalId":17402,"journal":{"name":"Journal of the Turkish Chemical Society, Section A: Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Turkish Chemical Society, Section A: Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18596/jotcsa.565054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 2

Abstract

In this study, gamma dose values were measured in the study area around a distance of 60 kmparallel to the Aegean Sea in Gure, Kucukkuyu and Kazdagi regions. In the study, gamma dose values were measured at 25 locations that best represent the area. These measurements were made by keeping the portable Eberline Smart Portable (ESP) scintillator detector constant at a height of 1 meter above ground level. A SPA-6 plastic scintillation sensor isconnected to the instrument tip to perform the measurement. These devices are direct measurement of external radiation. As the measurements were carried out in the open area,0.2 occupancy factor was used in the calculations. In the studies, the highest effective dose value was calculated as 0.3 mSv at the location 2 (Asos Kadirga Bay). The lowest effective dose value is 0.054 mSV at the 15th location (Avcilar Village Mountain slope) and the average annual gamma dose is 0.14 mSv. For the study area, when the lifetime risk of cancer was calculated using gamma effective dose values, it was determined at the highest 2 locations (1,2x10-3) and the lowest at the 15locations (0,21x10-3). The average lifetime cancer risk value (2,39x10 -4 ) of Turkey, were compared with values calculated in this study. In this comparison, the values of locations 9 and 15 were lower and the values of other locations were higher.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在和子山的behramkale (Çanakkale) ~ zeytİnlİ (edremİt-balikesİr)剖面上得到了地层单元的伽马剂量值
在这项研究中,在Gure、Kucukuyu和Kazdagi地区平行于爱琴海60公里的研究区域测量了伽马剂量值。在这项研究中,在25个最能代表该地区的位置测量了伽马剂量值。这些测量是通过在地面以上1米的高度保持便携式Eberline Smart portable(ESP)闪烁体探测器恒定来进行的。SPA-6塑料闪烁传感器连接到仪器尖端以执行测量。这些设备是对外部辐射的直接测量。由于测量是在开放区域进行的,因此计算中使用了0.2的占用系数。在这些研究中,在位置2(Asos Kadirga湾),最高有效剂量值计算为0.3 mSv。第15个位置(Avcilar村山坡)的最低有效剂量值为0.054 mSV,年平均伽马剂量为0.14 mSV。对于研究区域,当使用γ有效剂量值计算癌症的终身风险时,在最高的2个位置(1,2x10-3)确定,在最低的15个位置(0,21x10-3)。将土耳其癌症平均寿命风险值(2.39x10-4)与本研究中计算的值进行比较。在该比较中,位置9和15的值较低,而其他位置的值较高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.60
自引率
0.00%
发文量
81
审稿时长
5 weeks
期刊最新文献
Investigating the Effects of Fluorine Substituents on Organic Dyes in Dye-Sensitized Solar Cells Creating Nano-Sulfur from Sulfur Wastes in Mishraq Synthesis of Manganese(II), Iron(III), and Vanadium(IV) Complexes with New Schiff Bases and their Spectroscopic and Thermal Studies and Evaluation of their Antimicrobial Activity Preparation of PLGA-PEG/Hydroxyapatite Composites via Simple Methodology of Film Formation and Assessment of Their Structural, Thermal, and Biological Features Effect of AOT/Heptane Reverse Micelles on Oxidation of Ferroin by Metaperiodate: Kinetic and Mechanistic Aspects
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1