Temperature-Dependent Thermal Conductivity Measurement System for Various Heat Transfer Fluids

Q3 Engineering Instrumentation Mesure Metrologie Pub Date : 2021-08-31 DOI:10.18280/i2m.200403
Y. Anggraini, A. O. Silalahi, I. Sutjahja, D. Kurnia, S. Viridi, S. Wonorahardjo
{"title":"Temperature-Dependent Thermal Conductivity Measurement System for Various Heat Transfer Fluids","authors":"Y. Anggraini, A. O. Silalahi, I. Sutjahja, D. Kurnia, S. Viridi, S. Wonorahardjo","doi":"10.18280/i2m.200403","DOIUrl":null,"url":null,"abstract":"Accurate measurement of the thermal conductivity of a heat transfer fluid (HTF) is important for optimizing the performance of a thermal energy storage system. Herein, we develop a system to measure the thermal conductivity of an HTF during temperature variation, and the system was checked to measure several samples comprising water, lauric acid, stearic acid, oleic acid, and coconut oil. The thermal conductivity was measured using a KS-1 sensor of a KD2 Pro analyzer. In the study, a static heat conducting medium was used to control the temperature of the fluid, instead of the commonly used flowing water bath. The measured thermal conductivities of water (298 to 318 K) and lauric acid (323 to 373 K), stearic acid (358 to 372 K), oleic acid (334 to 372 K), and coconut oil (298 to 363 K) were compared to data from previous studies and fitted to available models. The accuracy of the data is further analyzed by relating the number of C and H atoms in the fatty acid, and the fatty acid content in coconut oil.","PeriodicalId":38637,"journal":{"name":"Instrumentation Mesure Metrologie","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instrumentation Mesure Metrologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18280/i2m.200403","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 4

Abstract

Accurate measurement of the thermal conductivity of a heat transfer fluid (HTF) is important for optimizing the performance of a thermal energy storage system. Herein, we develop a system to measure the thermal conductivity of an HTF during temperature variation, and the system was checked to measure several samples comprising water, lauric acid, stearic acid, oleic acid, and coconut oil. The thermal conductivity was measured using a KS-1 sensor of a KD2 Pro analyzer. In the study, a static heat conducting medium was used to control the temperature of the fluid, instead of the commonly used flowing water bath. The measured thermal conductivities of water (298 to 318 K) and lauric acid (323 to 373 K), stearic acid (358 to 372 K), oleic acid (334 to 372 K), and coconut oil (298 to 363 K) were compared to data from previous studies and fitted to available models. The accuracy of the data is further analyzed by relating the number of C and H atoms in the fatty acid, and the fatty acid content in coconut oil.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
各种传热流体的温度相关导热系数测量系统
准确测量传热流体的导热系数对于优化储热系统的性能具有重要意义。在此,我们开发了一个系统来测量温度变化时HTF的导热系数,并对该系统进行了测试,以测量几种样品,包括水、月桂酸、硬脂酸、油酸和椰子油。热导率测量采用KD2 Pro分析仪的KS-1传感器。在研究中,采用静态导热介质来控制流体的温度,而不是常用的流动水浴。测量的水(298至318 K)、月桂酸(323至373 K)、硬脂酸(358至372 K)、油酸(334至372 K)和椰子油(298至363 K)的导热系数与先前研究的数据进行了比较,并拟合到现有模型中。通过脂肪酸中C、H原子数与椰子油中脂肪酸含量的关系,进一步分析了数据的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Instrumentation Mesure Metrologie
Instrumentation Mesure Metrologie Engineering-Engineering (miscellaneous)
CiteScore
1.70
自引率
0.00%
发文量
25
期刊最新文献
A Device for Measuring the Electrical Conductivity of Liquids Using Phase Sensitive Detection Technique Design and Evaluation of a Spider Web-Like Single-Axis Micro-Electro-Mechanical Systems Accelerometer with High Sensitivity and Fast Response Investigating Fluid Flow Regimes: A Novel Design and Implementation of Bernoulli’s Apparatus Metrological Characterization of Spring Impact Hammer Calibration Advanced Sensor-Based Cap Cooling System for Mitigating Chemotherapy-Induced Hair Loss
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1