Olga Prokopová, Aleš Blahut, Jan Hajduch, Kateřina Kučnirová, Miroslav Čenský, Ali Aminian, Markus Richter, Václav Vinš
{"title":"Influence of Isomeric Composition and Sample Handling on the Liquid Density of Hydrofluorethers Measured by Vibrating Tube Densimeter at 0.1 MPa","authors":"Olga Prokopová, Aleš Blahut, Jan Hajduch, Kateřina Kučnirová, Miroslav Čenský, Ali Aminian, Markus Richter, Václav Vinš","doi":"10.1007/s10765-023-03247-6","DOIUrl":null,"url":null,"abstract":"<div><p>Hydrofluoroethers (HFEs) represent a new family of promising engineering fluids suitable for technical cleaning and cooling of electronic and magnetic devices or as admixtures in refrigerant blends. Here, we report accurate data for the liquid density at 0.1?MPa and temperatures from <span>\\(273.15\\,\\text{K}\\)</span> to <span>\\(343.15\\,\\text{K}\\)</span> for a series of five HFEs, namely, HFE-7000, HFE-7100, HFE-7200, HFE-7300, and HFE-7500. A highly sensitive vibrating tube densimeter with a borosilicate glass U-tube calibrated according to the procedure by Prokopová et al. (J Chem Thermodyn 173:106855, 2022) provided density data with an expanded uncertainty (<span>\\(k=2\\)</span>) of <span>\\(0.13\\,\\text{kg}\\cdot \\text{m}^{-3}\\)</span>. Influences such as sample degassing, water content, or sample temperature before its dosing into the densimeter are discussed. Thanks to the high sensitivity of the used densimeter, an unexpected shift in the density of different HFE-7100 and HFE-7200 liquid samples was detected. Unlike other HFEs, HFE-7100 and HFE-7200 are mixtures of two hardly separable isomers, which were so far considered having identical thermophysical properties. Utilizing nuclear magnetic resonance spectroscopy, the ratio of <i>n</i>-isomer and <i>iso</i>-isomer was inspected for various liquid samples. In the range of <i>iso</i>-isomer mole fraction from 0.61 to 0.77, the new measurements revealed density differences of more than <span>\\(5\\,\\text{kg}\\cdot \\text{m}^{-3}\\)</span> in case of HFE-7100 and of about <span>\\(3\\,\\text{kg}\\cdot \\text{m}^{-3}\\)</span> in case of HFE-7200. Consequently, for some applications, the properties of different HFE isomers cannot be considered identical. The Rackett-type correlation for the saturated liquid density was fitted using the new and the literature data.</p></div>","PeriodicalId":598,"journal":{"name":"International Journal of Thermophysics","volume":"44 9","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2023-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10765-023-03247-6.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Thermophysics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10765-023-03247-6","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Hydrofluoroethers (HFEs) represent a new family of promising engineering fluids suitable for technical cleaning and cooling of electronic and magnetic devices or as admixtures in refrigerant blends. Here, we report accurate data for the liquid density at 0.1?MPa and temperatures from \(273.15\,\text{K}\) to \(343.15\,\text{K}\) for a series of five HFEs, namely, HFE-7000, HFE-7100, HFE-7200, HFE-7300, and HFE-7500. A highly sensitive vibrating tube densimeter with a borosilicate glass U-tube calibrated according to the procedure by Prokopová et al. (J Chem Thermodyn 173:106855, 2022) provided density data with an expanded uncertainty (\(k=2\)) of \(0.13\,\text{kg}\cdot \text{m}^{-3}\). Influences such as sample degassing, water content, or sample temperature before its dosing into the densimeter are discussed. Thanks to the high sensitivity of the used densimeter, an unexpected shift in the density of different HFE-7100 and HFE-7200 liquid samples was detected. Unlike other HFEs, HFE-7100 and HFE-7200 are mixtures of two hardly separable isomers, which were so far considered having identical thermophysical properties. Utilizing nuclear magnetic resonance spectroscopy, the ratio of n-isomer and iso-isomer was inspected for various liquid samples. In the range of iso-isomer mole fraction from 0.61 to 0.77, the new measurements revealed density differences of more than \(5\,\text{kg}\cdot \text{m}^{-3}\) in case of HFE-7100 and of about \(3\,\text{kg}\cdot \text{m}^{-3}\) in case of HFE-7200. Consequently, for some applications, the properties of different HFE isomers cannot be considered identical. The Rackett-type correlation for the saturated liquid density was fitted using the new and the literature data.
期刊介绍:
International Journal of Thermophysics serves as an international medium for the publication of papers in thermophysics, assisting both generators and users of thermophysical properties data. This distinguished journal publishes both experimental and theoretical papers on thermophysical properties of matter in the liquid, gaseous, and solid states (including soft matter, biofluids, and nano- and bio-materials), on instrumentation and techniques leading to their measurement, and on computer studies of model and related systems. Studies in all ranges of temperature, pressure, wavelength, and other relevant variables are included.