Rancang Bangun Alat Ukur Ankle Brachial Indeks Untuk Deteksi Peripheral Artery Disease

R. W. Arsianti, Sardina Sardina, Fairul Fairul, Irfan Irfan, M. Mulyadi
{"title":"Rancang Bangun Alat Ukur Ankle Brachial Indeks Untuk Deteksi Peripheral Artery Disease","authors":"R. W. Arsianti, Sardina Sardina, Fairul Fairul, Irfan Irfan, M. Mulyadi","doi":"10.17529/jre.v16i3.17877","DOIUrl":null,"url":null,"abstract":"Abstract—ABI measurements are performed to detect PAD. ABI measurements are essential because, generally, patients are not aware of having PAD due to no significant signs and symptoms. Type 2 Diabetes Mellitus Patients tend to have PAD, which increases the risk of cardiovascular and mortality. Therefore, the measurement of ABI regularly is needed to prevent PAD. Early detection and regular monitoring of PAD by measuring ABI can avoid foot complications, such as injuries, gangrene, and amputation. The standard method to measure ABI is using Doppler. Unfortunately, not all health care providers have Doppler because it is an expensive instrument and relatively difficult to use. The purpose of this study is to design a simple and easy Prototype to measure ABI by using pressure sensors. Two pressure sensors measure the systole of blood pressure in the arm and leg to get the ABI. This study’s sample is 20 people consisting of 10 healthy people and ten diabetes mellitus patients. The result shows the ABI prototype has an error of 0.53% with an accuracy rate of 99.47%. It is indicated that the ABI prototype can be used for diagnosing PAD.","PeriodicalId":30766,"journal":{"name":"Jurnal Rekayasa Elektrika","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Rekayasa Elektrika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17529/jre.v16i3.17877","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract—ABI measurements are performed to detect PAD. ABI measurements are essential because, generally, patients are not aware of having PAD due to no significant signs and symptoms. Type 2 Diabetes Mellitus Patients tend to have PAD, which increases the risk of cardiovascular and mortality. Therefore, the measurement of ABI regularly is needed to prevent PAD. Early detection and regular monitoring of PAD by measuring ABI can avoid foot complications, such as injuries, gangrene, and amputation. The standard method to measure ABI is using Doppler. Unfortunately, not all health care providers have Doppler because it is an expensive instrument and relatively difficult to use. The purpose of this study is to design a simple and easy Prototype to measure ABI by using pressure sensors. Two pressure sensors measure the systole of blood pressure in the arm and leg to get the ABI. This study’s sample is 20 people consisting of 10 healthy people and ten diabetes mellitus patients. The result shows the ABI prototype has an error of 0.53% with an accuracy rate of 99.47%. It is indicated that the ABI prototype can be used for diagnosing PAD.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于外周动脉疾病检测的臂踝指数标度工具设计
摘要——ABI测量用于检测PAD。ABI测量是至关重要的,因为通常情况下,患者由于没有明显的体征和症状而没有意识到患有PAD。2型糖尿病患者往往患有PAD,这会增加心血管疾病和死亡率的风险。因此,需要定期测量ABI来预防PAD。通过测量ABI对PAD进行早期检测和定期监测可以避免足部并发症,如损伤、坏疽和截肢。测量ABI的标准方法是使用多普勒。不幸的是,并不是所有的医疗保健提供者都有多普勒,因为它是一种昂贵的仪器,而且相对难以使用。本研究的目的是设计一个简单易行的原型,通过使用压力传感器来测量ABI。两个压力传感器测量手臂和腿部的血压收缩,以获得ABI。本研究的样本为20人,包括10名健康人和10名糖尿病患者。结果表明,ABI原型诊断PAD的误差为0.53%,准确率为99.47%,可用于PAD的诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
24
审稿时长
24 weeks
期刊最新文献
Impact of Segmentation and Popularity-based Cache Replacement Policies on Named Data Networking Real-Time Detection of Power Quality Disturbance Using Fast Fourier Transform and Adaptive Neuro-Fuzzy Inference System Wireless Photoplethysmography (PPG) Measurement with Pulse Wave Velocity (PWV) Method for Arterial Stiffness Evaluation Augmentation of Additional Arabic Dataset for Jawi Writing and Classification Using Deep Learning Anomaly Detection for Security in Children's Play Areas Based on Image Using Multiple Lines Detection Method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1