V. M. Ramírez-Arrieta, D. Denis, Y. Ferrer-Sánchez
{"title":"Evaluación de un protocolo automatizado para la obtención de medidas morfométricas de huevos de aves a partir de fotografías digitales","authors":"V. M. Ramírez-Arrieta, D. Denis, Y. Ferrer-Sánchez","doi":"10.32800/abc.2021.44.0031","DOIUrl":null,"url":null,"abstract":"Evaluation of a protocol for automated extraction of morphometric measurements from avian eggs using digital photography\nAs many ecomorphological studies are limited by the time required to gather manual measurement data, automatizing the process is an important focus of methodological innovations. We developed, implemented and validated a protocol for the semi–automated extraction of a set of morphometric variables of egg size and shape from digital pictures. The protocol was implemented in R language as a web app called OvometriK. After binarizing and calibrating images, this protocol uses geometric and trigonometric functions to calculate eleven egg variables. We tested calculations in several ways, assuming contour continuity or using voxel counts. Application was validated with geometric shapes and 30 manually–measured chicken eggs. Mathematical validation with spheres showed that the algorithm provided high precision diameter measures, with a correlation of 99.9 %. Average estimation error was 1.4 %. The mathematical volume estimation was underestimated by 27 %, while voxels were underestimated by only 6 %. Differences between manual egg measurements of diameters and those obtained from images was less than 3 mm (4 %). Correlation between estimated volume and measured by silica gel filling was higher than 90 % using the voxel count method. Neither inclination angle or picture resolution had significant effects on precision (3.2 % maximum difference). Measures showed high repeatability and represent a significant saving in processing time. This new protocol represents an improvement on previous programs regarding limitations of platform, accessibility and number of variables. Furthermore, its flexibility and openness means it can be adapted to other specific applications.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2020-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.32800/abc.2021.44.0031","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Evaluation of a protocol for automated extraction of morphometric measurements from avian eggs using digital photography
As many ecomorphological studies are limited by the time required to gather manual measurement data, automatizing the process is an important focus of methodological innovations. We developed, implemented and validated a protocol for the semi–automated extraction of a set of morphometric variables of egg size and shape from digital pictures. The protocol was implemented in R language as a web app called OvometriK. After binarizing and calibrating images, this protocol uses geometric and trigonometric functions to calculate eleven egg variables. We tested calculations in several ways, assuming contour continuity or using voxel counts. Application was validated with geometric shapes and 30 manually–measured chicken eggs. Mathematical validation with spheres showed that the algorithm provided high precision diameter measures, with a correlation of 99.9 %. Average estimation error was 1.4 %. The mathematical volume estimation was underestimated by 27 %, while voxels were underestimated by only 6 %. Differences between manual egg measurements of diameters and those obtained from images was less than 3 mm (4 %). Correlation between estimated volume and measured by silica gel filling was higher than 90 % using the voxel count method. Neither inclination angle or picture resolution had significant effects on precision (3.2 % maximum difference). Measures showed high repeatability and represent a significant saving in processing time. This new protocol represents an improvement on previous programs regarding limitations of platform, accessibility and number of variables. Furthermore, its flexibility and openness means it can be adapted to other specific applications.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.