Comprehensive analysis of the start-up period of a full-scale drinking water biofilter provides guidance for optimization

L. Ramsay, I. L. Breda, D. A. Søborg
{"title":"Comprehensive analysis of the start-up period of a full-scale drinking water biofilter provides guidance for optimization","authors":"L. Ramsay, I. L. Breda, D. A. Søborg","doi":"10.5194/DWES-11-87-2018","DOIUrl":null,"url":null,"abstract":"Abstract. The use of biofilters to produce drinking water from anaerobic\ngroundwater is widespread in some European countries. A major disadvantage of\nbiofilters is the long start-up period required for virgin filter medium to\nbecome fully functional. Although individual aspects of biofilter start-up\nhave previously been investigated, no comprehensive study in full scale using\ninherent inoculation has previously been documented. A thorough investigation\nof a full-scale drinking water biofilter was carried out over 10 weeks of\nstart-up. The many spatial and temporal changes taking place during start-up\nwere documented using a holistic approach. In addition to collection of many\nsamples over time (frequency) and space (filter depth), this study entailed\nthe use of multiple sample media (water, backwash water and filter media) and\nmultiple types of analyses (physical, chemical and microbiological). The\ndecrease in filter effluent concentrations of individual substances to\ncompliance levels followed a specific order that was shown to coincide with\nthe spatiotemporal development of bacteria on the filter media. Due to the\nabiotic nature of the iron removal process, iron disappears at the earliest\nin the start-up period followed by substances that require growth of\nmicroorganisms. Ammonium disappears next, with nitrite appearing briefly near\nthe end of ammonium removal, followed by manganese. The thorough overall\npicture obtained by these efforts provides guidance for optimization and\nmonitoring of the start-up. Guidance for optimization includes shortening the\nstart-up by focusing on kick-starting the ammonium removal; limiting the\nmonitoring burden (at-line measurements of ammonium in finished water\nsupplemented with manual manganese measurements when ammonium removal is\ncomplete); and improving filter design by isolating the removal processes in\nseparate, smaller filters.\n","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drinking Water Engineering and Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/DWES-11-87-2018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 8

Abstract

Abstract. The use of biofilters to produce drinking water from anaerobic groundwater is widespread in some European countries. A major disadvantage of biofilters is the long start-up period required for virgin filter medium to become fully functional. Although individual aspects of biofilter start-up have previously been investigated, no comprehensive study in full scale using inherent inoculation has previously been documented. A thorough investigation of a full-scale drinking water biofilter was carried out over 10 weeks of start-up. The many spatial and temporal changes taking place during start-up were documented using a holistic approach. In addition to collection of many samples over time (frequency) and space (filter depth), this study entailed the use of multiple sample media (water, backwash water and filter media) and multiple types of analyses (physical, chemical and microbiological). The decrease in filter effluent concentrations of individual substances to compliance levels followed a specific order that was shown to coincide with the spatiotemporal development of bacteria on the filter media. Due to the abiotic nature of the iron removal process, iron disappears at the earliest in the start-up period followed by substances that require growth of microorganisms. Ammonium disappears next, with nitrite appearing briefly near the end of ammonium removal, followed by manganese. The thorough overall picture obtained by these efforts provides guidance for optimization and monitoring of the start-up. Guidance for optimization includes shortening the start-up by focusing on kick-starting the ammonium removal; limiting the monitoring burden (at-line measurements of ammonium in finished water supplemented with manual manganese measurements when ammonium removal is complete); and improving filter design by isolating the removal processes in separate, smaller filters.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对全尺寸饮用水生物滤池的启动周期进行综合分析,为优化提供指导
摘要在一些欧洲国家,使用生物过滤器从厌氧地下水中生产饮用水的做法很普遍。生物过滤器的一个主要缺点是原始过滤介质需要很长的启动时间才能完全发挥作用。尽管之前已经对生物过滤器启动的各个方面进行了研究,但之前没有使用固有接种进行全面研究的记录。在启动的10周内,对全尺寸饮用水生物过滤器进行了彻底的研究。使用整体方法记录了启动上升过程中发生的许多空间和时间变化。除了收集随时间(频率)和空间(过滤器深度)变化的许多样本外,本研究还需要使用多种样本介质(水、反冲洗水和过滤器介质)和多种类型的分析(物理、化学和微生物)。单个物质的过滤出水浓度降低到符合水平遵循特定的顺序,这与过滤介质上细菌的时空发展相一致。由于除铁过程的生物性质,铁在启动初期就消失了,随后是需要微生物生长的物质。铵随后消失,亚硝酸盐在铵去除结束时短暂出现,其次是锰。通过这些努力获得的全面情况为启动的优化和监控提供了指导。优化指导包括通过集中精力启动脱铵来缩短启动时间;限制监测负荷(当铵去除完成时,用手动锰测量补充成品水中铵的在线测量);以及通过将去除过程隔离开来改进过滤器设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Drinking Water Engineering and Science
Drinking Water Engineering and Science Environmental Science-Water Science and Technology
CiteScore
3.90
自引率
0.00%
发文量
3
审稿时长
40 weeks
期刊最新文献
The evaluation of hydraulic reliability indices in water distribution networks under pipe failure conditions Technical note: Graph theory-based heuristics to aid in the implementation of optimized drinking water network sectorization Solar distillation of impure water from four different water sources under the southwestern Nigerian climate Sustainability characteristics of drinking water supply in the Netherlands Preparation of thin-film composite membranes supported with electrospun nanofibers for desalination by forward osmosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1