{"title":"Comparison of Ease and Success of Intubation through LMA Blockbuster and Ambu Aura-I in Patients Receiving General Anesthesia","authors":"M. Manohar, Hemanth Tirupathi, Prashant Kumar, K. Kaur, Sumedha Vashishth, N. Bangarwa","doi":"10.4103/mamcjms.mamcjms_21_23","DOIUrl":null,"url":null,"abstract":"Background: Airway gadgetry is expanding at an exponential rate. It is imperative to understand the intubating characteristics of supraglottic devices so that the choice of device in patients is based on evidence rather than just the design. The present study was conducted to compare blind intubation with blockbuster LMA and Ambu Aura-i. Methodology: Sixty patients of either sex, 20 to 60 years of age, ASA I–III, scheduled to undergo elective surgery under general anesthesia, were included in this prospective, randomized, comparative study. Group A (n = 30) patients were intubated with AmbuAura-i, and Group B (n = 30) patients were intubated using BlockBuster LMA. Results: Endotracheal intubation was found easy in 76% of the patients and difficult in 10% of the patients intubated with Ambu Aura −i. A 13.3% failure rate was observed in group A. Intubation success rate of 100% was observed in Group B. 86.6% of patients were easily intubated, and seven patients were intubated with a bit of difficulty (P-value 0.010). The mean time of SGD insertion in Group A was 14.77 ± 5.563 seconds, and in Group B was 21.87 ± 7.186 seconds (P-value 0.000). SGD insertion attempts were significantly higher in Group B when compared to Group A (P-value 0.025). Conclusion: Although AA-i requires less time for the placement of SGD, blockbuster LMA remains the better choice with a 100% success rate of blind orotracheal intubation.","PeriodicalId":32900,"journal":{"name":"MAMC Journal of Medical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MAMC Journal of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/mamcjms.mamcjms_21_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Airway gadgetry is expanding at an exponential rate. It is imperative to understand the intubating characteristics of supraglottic devices so that the choice of device in patients is based on evidence rather than just the design. The present study was conducted to compare blind intubation with blockbuster LMA and Ambu Aura-i. Methodology: Sixty patients of either sex, 20 to 60 years of age, ASA I–III, scheduled to undergo elective surgery under general anesthesia, were included in this prospective, randomized, comparative study. Group A (n = 30) patients were intubated with AmbuAura-i, and Group B (n = 30) patients were intubated using BlockBuster LMA. Results: Endotracheal intubation was found easy in 76% of the patients and difficult in 10% of the patients intubated with Ambu Aura −i. A 13.3% failure rate was observed in group A. Intubation success rate of 100% was observed in Group B. 86.6% of patients were easily intubated, and seven patients were intubated with a bit of difficulty (P-value 0.010). The mean time of SGD insertion in Group A was 14.77 ± 5.563 seconds, and in Group B was 21.87 ± 7.186 seconds (P-value 0.000). SGD insertion attempts were significantly higher in Group B when compared to Group A (P-value 0.025). Conclusion: Although AA-i requires less time for the placement of SGD, blockbuster LMA remains the better choice with a 100% success rate of blind orotracheal intubation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
LMA Blockbuster与Ambu Aura-I在全麻患者插管的简易性和成功率比较
背景:气道小器具正以指数速度扩张。了解声门上装置的插管特点是非常必要的,这样患者在选择设备时就会基于证据而不仅仅是设计。本研究比较了盲目插管与大片LMA和Ambu Aura-i。方法:60例20 - 60岁、ASA I-III级、计划在全身麻醉下进行择期手术的男女患者被纳入这项前瞻性、随机、比较研究。A组(n = 30)患者插管使用AmbuAura-i, B组(n = 30)患者插管使用BlockBuster LMA。结果:使用Ambu Aura−i气管插管,76%的患者气管插管容易,10%的患者插管困难。A组插管失败率为13.3%,b组插管成功率为100%,86.6%的患者插管容易,7例患者插管困难(p值为0.010)。A组置入SGD的平均时间为14.77±5.563 s, B组置入SGD的平均时间为21.87±7.186 s (p值0.000)。与A组相比,B组SGD插入次数显著增加(p值为0.025)。结论:虽然AA-i放置SGD所需时间较少,但大片LMA仍然是更好的选择,其盲口气管插管成功率为100%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
20 weeks
期刊最新文献
The clinical, sociodemographic, and pharmacotherapeutic characteristics influencing quality of life in patients with epilepsy Should planning of cervical pedicle screws be race specific? Computed tomography–based morphometric analysis A Prospective Clinical Evaluation of Adhesive Small Bowel Obstruction in Infants and Children A randomized controlled study to compare the dose requirement of oxytocin for management of uterine atony in patients receiving prophylactic phenylephrine during caesarean delivery Artificial intelligence and healthcare
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1