Third Order Adjoint Sensitivity and Uncertainty Analysis of an OECD/NEA Reactor Physics Benchmark: III. Response Moments

R. Fang, D. Cacuci
{"title":"Third Order Adjoint Sensitivity and Uncertainty Analysis of an OECD/NEA Reactor Physics Benchmark: III. Response Moments","authors":"R. Fang, D. Cacuci","doi":"10.4236/ajcm.2020.104031","DOIUrl":null,"url":null,"abstract":"The (180)3 third-order mixed sensitivities of the leakage response of a polyethylene-reflected plutonium (PERP) experimental benchmark with respect to the benchmark’s 180 microscopic total cross sections have been computed in accompanying works [1] [2]. This work quantifies the contributions of these (180)3 third-order mixed sensitivities to the PERP benchmark’s leakage response distribution moments (expected value, variance and skewness) and compares these contributions to those stemming from the corresponding first- and second-order sensitivities of the PERP benchmark’s leakage response with respect to the total cross sections. The numerical results obtained in this work reveal that the importance of the 3rd-order sensitivities can surpass the importance of the 1st- and 2nd-order sensitivities when the parameters’ uncertainties increase. In particular, for a uniform standard deviation of 10% of the microscopic total cross sections, the 3rd-order sensitivities contribute 80% to the response variance, whereas the contribution stemming from the 1st- and 2nd-order sensitivities amount only to 2% and 18%, respectively. Consequently, neglecting the 3rd-order sensitivities could cause a very large non-conservative error by under-reporting the response variance by a factor of 506%. The results obtained in this work also indicate that the effects of the 3rd-order sensitivities are to reduce the response’s skewness in parameter space, rendering the distribution of the leakage response more symmetric about its expected value. The results obtained in this work are the first such results ever published in reactor physics. Since correlations among the group-averaged microscopic total cross sections are not available, only the effects of typical standard deviations for these cross sections could be considered. Due to this lack of correlations among the cross sections, the effects of the mixed 3rd-order sensitivities could not be quantified exactly at this time. These effects could be quantified only when correlations among the group-averaged microscopic total cross sections would be obtained experimentally by the nuclear physics community.","PeriodicalId":64456,"journal":{"name":"美国计算数学期刊(英文)","volume":"10 1","pages":"559-570"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"美国计算数学期刊(英文)","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.4236/ajcm.2020.104031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

The (180)3 third-order mixed sensitivities of the leakage response of a polyethylene-reflected plutonium (PERP) experimental benchmark with respect to the benchmark’s 180 microscopic total cross sections have been computed in accompanying works [1] [2]. This work quantifies the contributions of these (180)3 third-order mixed sensitivities to the PERP benchmark’s leakage response distribution moments (expected value, variance and skewness) and compares these contributions to those stemming from the corresponding first- and second-order sensitivities of the PERP benchmark’s leakage response with respect to the total cross sections. The numerical results obtained in this work reveal that the importance of the 3rd-order sensitivities can surpass the importance of the 1st- and 2nd-order sensitivities when the parameters’ uncertainties increase. In particular, for a uniform standard deviation of 10% of the microscopic total cross sections, the 3rd-order sensitivities contribute 80% to the response variance, whereas the contribution stemming from the 1st- and 2nd-order sensitivities amount only to 2% and 18%, respectively. Consequently, neglecting the 3rd-order sensitivities could cause a very large non-conservative error by under-reporting the response variance by a factor of 506%. The results obtained in this work also indicate that the effects of the 3rd-order sensitivities are to reduce the response’s skewness in parameter space, rendering the distribution of the leakage response more symmetric about its expected value. The results obtained in this work are the first such results ever published in reactor physics. Since correlations among the group-averaged microscopic total cross sections are not available, only the effects of typical standard deviations for these cross sections could be considered. Due to this lack of correlations among the cross sections, the effects of the mixed 3rd-order sensitivities could not be quantified exactly at this time. These effects could be quantified only when correlations among the group-averaged microscopic total cross sections would be obtained experimentally by the nuclear physics community.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
OECD/NEA反应堆物理基准的三阶伴随灵敏度和不确定性分析:2。响应的时刻
在相关著作[1][2]中,计算了聚乙烯反射钚(PERP)实验基准泄漏响应的(180)3三阶混合灵敏度相对于基准的180个微观总截面。这项工作量化了这(180)3个三阶混合灵敏度对PERP基准泄漏响应分布矩(期望值、方差和偏度)的贡献,并将这些贡献与PERP基准泄漏响应的相应一阶和二阶灵敏度相对于总截面的贡献进行了比较。数值结果表明,当参数的不确定性增加时,三阶灵敏度的重要性可以超过一阶和二阶灵敏度的重要性。特别是,当微观总截面的均匀标准差为10%时,三阶灵敏度对响应方差的贡献为80%,而一阶和二阶灵敏度的贡献分别仅为2%和18%。因此,忽略三阶灵敏度可能会因少报506%的响应方差而导致非常大的非保守误差。研究结果还表明,三阶灵敏度的作用是降低响应在参数空间上的偏度,使泄漏响应的分布与其期望值更加对称。在这项工作中获得的结果是首次在反应堆物理学上发表这样的结果。由于群体平均微观总横截面之间的相关性不可用,因此只能考虑这些横截面的典型标准差的影响。由于截面之间缺乏相关性,混合三阶灵敏度的影响此时无法精确量化。这些效应只有在核物理学界通过实验获得群平均微观总截面之间的相关性时才能量化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
348
期刊最新文献
Diophantine Quotients and Remainders with Applications to Fermat and Pythagorean Equations Quantization of the Kinetic Energy of Deterministic Chaos On Fermat Last Theorem: The New Efficient Expression of a Hypothetical Solution as a Function of Its Fermat Divisors Analyzing Electric Circuits with Computer Algebra Arithmetic Operations of Generalized Trapezoidal Picture Fuzzy Numbers by Vertex Method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1