Evaluation and Comparison of Removable Dentures Constructed with The SR-IVOCAP System and The Traditional System.

Prof. Edit Xhajanka, Dr. Neada Hysenaj, Prof. Dr. Vergjini Mulo, Dr. Dorina Mele, Dr. Tedi Verçani, Dr. Endrit Paparisto
{"title":"Evaluation and Comparison of Removable Dentures Constructed with The SR-IVOCAP System and The Traditional System.","authors":"Prof. Edit Xhajanka, Dr. Neada Hysenaj, Prof. Dr. Vergjini Mulo, Dr. Dorina Mele, Dr. Tedi Verçani, Dr. Endrit Paparisto","doi":"10.22376/ijlpr.2023.13.5.l302-l310","DOIUrl":null,"url":null,"abstract":"The treatment of edentulous patients is still a challenging problem. Acrylic resin is the most used material forconstructing removable denture bases. The main disadvantage of this material is resin shrinkage, which occurs during and afterpolymerization. Our study aimed to evaluate the denture parameters regarding patient satisfaction regarding the removabledentures constructed with two different processing techniques: compression molding and injection. 80 patients, who came in theUniversity Dental Clinic, Tirana were examined and evaluated. Those who fulfilled the criteria were treated with removabledentures. The patients were divided into two groups: in the first group, 40 patients were treated with removable denturesconstructed with the compression molding technique, and in the second group, 40 patients were treated with removable denturesconstructed with the injection molding technique. All the clinical and laboratory procedures until the processing technique wereidentical. After denture delivery, all the patients were re-scheduled to fulfill a questionnaire regarding four parameters of theremovable dentures: denture stability, mastication efficiency, denture comfort, and quality of dentures in general. Results. Thedescriptive statistics of the data were done. Sample t-test showed that the SR IVOCAP dentures had higher mean values for allthe parameters than the traditional dentures. Based on our study, the satisfaction of the patients treated with removable dentureswith the SR-IVOCAP system for all the parameters evaluated was higher compared to the patient satisfaction treated withtraditional removable dentures.","PeriodicalId":44665,"journal":{"name":"International Journal of Life Science and Pharma Research","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Life Science and Pharma Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22376/ijlpr.2023.13.5.l302-l310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The treatment of edentulous patients is still a challenging problem. Acrylic resin is the most used material forconstructing removable denture bases. The main disadvantage of this material is resin shrinkage, which occurs during and afterpolymerization. Our study aimed to evaluate the denture parameters regarding patient satisfaction regarding the removabledentures constructed with two different processing techniques: compression molding and injection. 80 patients, who came in theUniversity Dental Clinic, Tirana were examined and evaluated. Those who fulfilled the criteria were treated with removabledentures. The patients were divided into two groups: in the first group, 40 patients were treated with removable denturesconstructed with the compression molding technique, and in the second group, 40 patients were treated with removable denturesconstructed with the injection molding technique. All the clinical and laboratory procedures until the processing technique wereidentical. After denture delivery, all the patients were re-scheduled to fulfill a questionnaire regarding four parameters of theremovable dentures: denture stability, mastication efficiency, denture comfort, and quality of dentures in general. Results. Thedescriptive statistics of the data were done. Sample t-test showed that the SR IVOCAP dentures had higher mean values for allthe parameters than the traditional dentures. Based on our study, the satisfaction of the patients treated with removable dentureswith the SR-IVOCAP system for all the parameters evaluated was higher compared to the patient satisfaction treated withtraditional removable dentures.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SR-IVOCAP系统与传统系统构建活动义齿的评价与比较。
缺牙患者的治疗仍然是一个具有挑战性的问题。丙烯酸树脂是构造可摘义齿基托最常用的材料。这种材料的主要缺点是树脂收缩,这种收缩发生在聚合过程中和聚合后。我们的研究旨在评估使用两种不同加工技术(压缩成型和注射)构建的可移除义齿的患者满意度的义齿参数。来自地拉那大学牙科诊所的80名患者接受了检查和评估。符合标准的患者接受可移除义齿治疗。将患者分为两组:第一组40例采用挤压成型技术构建的可摘义齿进行治疗,第二组40例患者采用注射成型技术构建可摘义齿。所有的临床和实验室程序,直到处理技术是相同的。义齿交付后,所有患者都被重新安排完成一份关于可移动义齿四个参数的问卷:义齿稳定性、咀嚼效率、义齿舒适度和义齿质量。后果对数据进行描述性统计。样本t检验表明,SR IVOCAP义齿的所有参数的平均值均高于传统义齿。根据我们的研究,与使用传统可摘义齿治疗的患者满意度相比,使用SR-IVOCAP系统治疗可摘义齿的患者对所有评估参数的满意度更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
50.00%
发文量
525
期刊最新文献
Musical Intervention: An Evolutionary Era in Dentistry Study on Relationship Between Early Smartphone Use and Academic Performance in College Going Students in and Around Karad Advancing Carvedilol's Therapeutic Impact: A Study On Solid Dispersion Capsules for Improved Efficacy Experimental Study on the Effect of Sprint Interval Training Versus Traditional Exercise Programs Among Young Obese Adults. Formulation and Evaluation of Linagliptin Buccal Films
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1