Whole-breast irradiation with lumpectomy cavity boost and regional nodal irradiation: Dosimetric comparison of 3D-CRT using sequential boost and dual partial-arc VMAT using simultaneous integrated boost.

IF 2.1 Q4 Medicine Precision Radiation Oncology Pub Date : 2023-06-25 eCollection Date: 2023-06-01 DOI:10.1002/pro6.1203
Avinash Poojari, Shantanu Sapru, Rohini Khurana, Madhup Rastogi, Rahat Hadi, Ajeet Kumar Gandhi, Surendra Mishra, Anoop Srivastava, Avinav Bharati
{"title":"Whole-breast irradiation with lumpectomy cavity boost and regional nodal irradiation: Dosimetric comparison of 3D-CRT using sequential boost and dual partial-arc VMAT using simultaneous integrated boost.","authors":"Avinash Poojari, Shantanu Sapru, Rohini Khurana, Madhup Rastogi, Rahat Hadi, Ajeet Kumar Gandhi, Surendra Mishra, Anoop Srivastava, Avinav Bharati","doi":"10.1002/pro6.1203","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare volumetric modulated arc therapy (VMAT) with simultaneous tumor bed boost (dpSIB-VMAT) to the whole breast and regional nodal irradiation (RNI) against standard three-dimensional conformal radiotherapy plus RNI with sequential tumor bed boost (3D-CRT-seqB).</p><p><strong>Methods: </strong>Thirty patients who underwent breast cancer surgery (BCS) with axillary lymph node dissection (ALND) were enrolled. Two plans were generated for each case: (1) dpSIB-VMAT, and (2) 3D-CRT-seqB plans. Planning target volume (PTV)-Breast and PTV-Nodes were prescribed at a dose of 50 Gy in 25 fractions in both plans. PTV-Boost was prescribed at a dose of 60 Gy in 25 fractions simultaneously in the dpSIB-VMAT plans, whereas it was planned sequentially in the 3D-CRT-seqB plans at 10 Gy in 5 fractions. Dosimetric parameters were compared between the two plans.</p><p><strong>Results: </strong>Both plans achieved the target coverage. D<sub>mean</sub> of the heart was lower with dpSIB-VMAT in left-sided cases (7.17 ± 0.66 Gy vs. 10.12 ± 2.91 Gy; <i>t</i> = 4.02; <i>p</i> = 0.001). Ipsilateral mean lung dose (15.87 ± 1.40 Gy vs. 19.82 ± 3.20 Gy; <i>t</i> = 6.30; <i>p</i><0.001) was significantly lower but mean doses of the contralateral breast (4.30 ± 1.76 Gy vs. 1.48 ± 0.76 Gy; <i>t</i> = -7.84; <i>p</i><0.001), contralateral lung (3.86 ± 1.21 Gy vs. 0.96 ± 0.25 Gy; <i>t</i> = -13.13; <i>p</i><0.001) and esophagus (13.11 ± 2.63 Gy vs. 10.32 ± 3.56 Gy; <i>t</i> = -6.65; <i>p</i><0.001) were relatively higher with dpSIB-VMAT.</p><p><strong>Conclusion: </strong>Dosimetrically, dpSIB-VMAT reduced doses to the ipsilateral lung and heart (in left breast but not right breast cases) compared to 3D-CRT-seqB plans for adequate target coverage.</p>","PeriodicalId":32406,"journal":{"name":"Precision Radiation Oncology","volume":"7 1","pages":"118-127"},"PeriodicalIF":2.1000,"publicationDate":"2023-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11934988/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Precision Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/pro6.1203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare volumetric modulated arc therapy (VMAT) with simultaneous tumor bed boost (dpSIB-VMAT) to the whole breast and regional nodal irradiation (RNI) against standard three-dimensional conformal radiotherapy plus RNI with sequential tumor bed boost (3D-CRT-seqB).

Methods: Thirty patients who underwent breast cancer surgery (BCS) with axillary lymph node dissection (ALND) were enrolled. Two plans were generated for each case: (1) dpSIB-VMAT, and (2) 3D-CRT-seqB plans. Planning target volume (PTV)-Breast and PTV-Nodes were prescribed at a dose of 50 Gy in 25 fractions in both plans. PTV-Boost was prescribed at a dose of 60 Gy in 25 fractions simultaneously in the dpSIB-VMAT plans, whereas it was planned sequentially in the 3D-CRT-seqB plans at 10 Gy in 5 fractions. Dosimetric parameters were compared between the two plans.

Results: Both plans achieved the target coverage. Dmean of the heart was lower with dpSIB-VMAT in left-sided cases (7.17 ± 0.66 Gy vs. 10.12 ± 2.91 Gy; t = 4.02; p = 0.001). Ipsilateral mean lung dose (15.87 ± 1.40 Gy vs. 19.82 ± 3.20 Gy; t = 6.30; p<0.001) was significantly lower but mean doses of the contralateral breast (4.30 ± 1.76 Gy vs. 1.48 ± 0.76 Gy; t = -7.84; p<0.001), contralateral lung (3.86 ± 1.21 Gy vs. 0.96 ± 0.25 Gy; t = -13.13; p<0.001) and esophagus (13.11 ± 2.63 Gy vs. 10.32 ± 3.56 Gy; t = -6.65; p<0.001) were relatively higher with dpSIB-VMAT.

Conclusion: Dosimetrically, dpSIB-VMAT reduced doses to the ipsilateral lung and heart (in left breast but not right breast cases) compared to 3D-CRT-seqB plans for adequate target coverage.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肿块切除腔增强和区域淋巴结照射的全乳腺照射:顺序增强的3D-CRT和同时集成增强的双部分弧VMAT的剂量比较
将体积调制电弧治疗(VMAT)与同时肿瘤床增强(dpSIB‐VMAT)对全乳腺和区域淋巴结照射(RNI)与标准三维适形放射治疗加RNI与顺序肿瘤床加强(3D‐CRT‐seqB)进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Precision Radiation Oncology
Precision Radiation Oncology Medicine-Oncology
CiteScore
1.20
自引率
0.00%
发文量
32
审稿时长
13 weeks
期刊最新文献
V15(Gy) as a predictor of asymptomatic radiation pneumonitis in patients with lung cancer: A retrospective dosimetric analysis. Peripheral T-cell lymphoma with central nervous system involvement and elevated interleukin-10 levels in the cerebrospinal fluid: A case report. Exploring the potential benefits of multi-field IMPT for stage I NSCLC SBRT: An in silico dosimetric comparison to IMRT and CyberKnife. Dosimetric assessment of conventional and advanced algorithms in clinical stereotactic radiotherapy. Incidence, risk factors, and CT characteristics of radiation recall pneumonitis induced by COVID-19 infection in lung cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1