Measurement of melamine migration from melamine-ware products by designed HPLC method and the effect of food-type on the level of migration

Q3 Environmental Science Interdisciplinary Toxicology Pub Date : 2018-12-01 DOI:10.2478/intox-2018-0031
E. Haghi, M. Alimohammadi, Attaollah Shakoori, Fariba Razeghi, P. Sadighara
{"title":"Measurement of melamine migration from melamine-ware products by designed HPLC method and the effect of food-type on the level of migration","authors":"E. Haghi, M. Alimohammadi, Attaollah Shakoori, Fariba Razeghi, P. Sadighara","doi":"10.2478/intox-2018-0031","DOIUrl":null,"url":null,"abstract":"Abstract Melamine-ware is widely used around the world. There is a public health concern as regards the safety of melamine when exposed to food. This study was carried out to measure the level of melamine migration in melamine-ware products by HPLC method and the effect of food-type on the level of melamine migration. In food control laboratories in Iran, there is no common method to measure and monitor melamine migration, hence a method using HPLC technique was adopted and validated to solve this problem. The validation results showed the reliability with 94.9% accuracy and 95.3% precision. Furthermore, the limit of detection (LOD) and quantification (LOQ) were 0.145 and 0.435 µg/ml, which for a new method were within acceptable ranges. Melamine migrations from 4 most available melamine wares were measured. Distilled water, 3% acetic acid and 15% ethanol were used as food simulant at 30 °C for 90 min. Although melamine migration occurred in all samples and acidic conditions had a significant effect, the values were not higher than the European standard (30 µg/ml). The study revealed that the HPLC method was valid and could be applied and developed to measure melamine migration. However, precautions should be considered while choosing melamine-ware utensil as long-term exposure to this substance has a negative effect on health, especially on the kidneys.","PeriodicalId":13715,"journal":{"name":"Interdisciplinary Toxicology","volume":"11 1","pages":"316 - 320"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interdisciplinary Toxicology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/intox-2018-0031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 7

Abstract

Abstract Melamine-ware is widely used around the world. There is a public health concern as regards the safety of melamine when exposed to food. This study was carried out to measure the level of melamine migration in melamine-ware products by HPLC method and the effect of food-type on the level of melamine migration. In food control laboratories in Iran, there is no common method to measure and monitor melamine migration, hence a method using HPLC technique was adopted and validated to solve this problem. The validation results showed the reliability with 94.9% accuracy and 95.3% precision. Furthermore, the limit of detection (LOD) and quantification (LOQ) were 0.145 and 0.435 µg/ml, which for a new method were within acceptable ranges. Melamine migrations from 4 most available melamine wares were measured. Distilled water, 3% acetic acid and 15% ethanol were used as food simulant at 30 °C for 90 min. Although melamine migration occurred in all samples and acidic conditions had a significant effect, the values were not higher than the European standard (30 µg/ml). The study revealed that the HPLC method was valid and could be applied and developed to measure melamine migration. However, precautions should be considered while choosing melamine-ware utensil as long-term exposure to this substance has a negative effect on health, especially on the kidneys.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用设计的高效液相色谱法测定三聚氰胺制品中三聚氰胺的迁移量以及食品类型对迁移水平的影响
摘要三聚氰胺制品在世界各地广泛使用。公众关注三聚氰胺在接触食物时的安全性。本研究采用高效液相色谱法测定了三聚氰胺制品中三聚氰胺的迁移水平,以及食品类型对三聚氰胺迁移水平的影响。在伊朗的食品控制实验室中,没有常用的方法来测量和监测三聚氰胺的迁移,因此采用了高效液相色谱技术来解决这一问题。验证结果表明,该方法具有94.9%的准确度和95.3%的精密度。此外,检测限(LOD)和定量限(LOQ)分别为0.145和0.435µg/ml,对于一种新方法来说,这两个值都在可接受的范围内。测量了4种最常见的三聚氰胺制品的三聚氰胺迁移。蒸馏水、3%乙酸和15%乙醇用作食品模拟物,温度为30°C,持续90分钟。尽管三聚氰胺在所有样品中都发生了迁移,酸性条件也有显著影响,但其值并不高于欧洲标准(30µg/ml)。研究表明,高效液相色谱法是有效的,可用于三聚氰胺迁移的测定。然而,在选择三聚氰胺餐具时应考虑预防措施,因为长期接触这种物质会对健康产生负面影响,尤其是对肾脏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Interdisciplinary Toxicology
Interdisciplinary Toxicology Pharmacology, Toxicology and Pharmaceutics-Pharmacology
自引率
0.00%
发文量
0
审稿时长
18 weeks
期刊最新文献
Effect of tramadol dependence on male sexual dysfunction. Melamine migration measurement through spectrophotometry device and the effect of time and tableware type on it. Mechanism of protection of rat hepatocytes from acetaminophen-induced cellular damage by ethanol extract of Aerva lanata. Biochemical and histopathological effects of sub-acute exposure of albino rats to fumigants - dichlorvos and cypermethrin. The hepatoprotective and antioxidative effect of saffron stigma alcoholic extract against vincristine sulfate induced toxicity in rats.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1