Evaluation of Removal Force in Prosthetic Components of Morse Taper Dental Implants

Q2 Medicine Brazilian dental journal Pub Date : 2022-10-01 DOI:10.1590/0103-6440202205084
Angelo Marcelo Tirado Dos Santos, G. A. V. Stabile, K. R. Felizardo, Sérgio Eduardo Ramos Dos Santos Júnior, S. Berger, R. Guiraldo, Alcides Gonini Júnior, M. Lopes
{"title":"Evaluation of Removal Force in Prosthetic Components of Morse Taper Dental Implants","authors":"Angelo Marcelo Tirado Dos Santos, G. A. V. Stabile, K. R. Felizardo, Sérgio Eduardo Ramos Dos Santos Júnior, S. Berger, R. Guiraldo, Alcides Gonini Júnior, M. Lopes","doi":"10.1590/0103-6440202205084","DOIUrl":null,"url":null,"abstract":"Abstract The longevity of prosthetic rehabilitation is determined by the stability of the implant and abutment interfaces. True morse taper connections on dental restorations have been effective, however activation force still empirical. This work compared the activation strength and internal contact of Morse taper system according to the removal force. Eighty sets, composed of implants and prosthetic abutments, were evaluated with different internal contact areas; 15.12mm2 (G3.3) and 21.25mm2 (G4.3). The specimens were activated at 0° and 30°, with loads of 10, 20, 40 and 60N. The specimens were submitted to tensile test and the data to ANOVA and Tukey’s tests (α=0.05). Representative specimens were examined under SEM. Removal force of G3.3 (2.15±1.33MPa) did not differed to G4.3 (1.99±1.03MPa). The activation at 0º (2.95±0.98MPa) statistically differed to 30º (1.19±0.54MPa). The 60N load was statistically superior for G3.3 and there was no statistical difference between 20N to 60N in G4.3. The values of 10N at 30o and 20N at the long axis of the morse taper implant, independent of the frictional contact area showed the best settlement.","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"33 1","pages":"74 - 80"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian dental journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0103-6440202205084","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract The longevity of prosthetic rehabilitation is determined by the stability of the implant and abutment interfaces. True morse taper connections on dental restorations have been effective, however activation force still empirical. This work compared the activation strength and internal contact of Morse taper system according to the removal force. Eighty sets, composed of implants and prosthetic abutments, were evaluated with different internal contact areas; 15.12mm2 (G3.3) and 21.25mm2 (G4.3). The specimens were activated at 0° and 30°, with loads of 10, 20, 40 and 60N. The specimens were submitted to tensile test and the data to ANOVA and Tukey’s tests (α=0.05). Representative specimens were examined under SEM. Removal force of G3.3 (2.15±1.33MPa) did not differed to G4.3 (1.99±1.03MPa). The activation at 0º (2.95±0.98MPa) statistically differed to 30º (1.19±0.54MPa). The 60N load was statistically superior for G3.3 and there was no statistical difference between 20N to 60N in G4.3. The values of 10N at 30o and 20N at the long axis of the morse taper implant, independent of the frictional contact area showed the best settlement.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Morse锥牙种植体修复部件去除力的评价
摘要假体康复的寿命取决于植入物和基牙界面的稳定性。真正的莫氏锥度连接在牙齿修复中是有效的,但激活力仍然是经验的。本工作根据去除力对Morse锥形系统的激活强度和内部接触进行了比较。80套由植入物和人工基牙组成,在不同的内部接触面积下进行了评估;15.12mm2(G3.3)和21.25mm2(G4.3)。试样在0°和30°下活化,载荷分别为10、20、40和60N。将试样进行拉伸试验,并将数据进行方差分析和Tukey检验(α=0.05)。在SEM下检查代表性试样。G3.3的去除力(2.15±1.33MPa)与G4.3(1.99±1.03MPa)无差异。0º(2.95±0.98MPa)与30º(1.19±0.54MPa)的活化有统计学差异。G3.3的60N负荷在统计学上优于G4.3,G4.3的20N与60N之间无统计学差异。morse锥形植入物长轴30o处的10N和20N的值与摩擦接触面积无关,显示出最佳的沉降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Brazilian dental journal
Brazilian dental journal Dentistry-Dentistry (all)
CiteScore
2.20
自引率
0.00%
发文量
69
审稿时长
12 weeks
期刊介绍: Brazilian Dental Journal, publishes Full-Length Papers, Short Communications and Case Reports, dealing with dentistry or related disciplines and edited six times a year.
期刊最新文献
Can a dentin bonding agent prevent color change in regenerative endodontic procedures? An in vitro evaluation Antibacterial ability of different activated irrigation after root canal preparation: intratubular analyses Inhibition of incipient caries lesion progression by different fluoridated varnishes A new hydroxyapatite-alginate-gelatin biocomposite favor bone regeneration in a critical-sized calvarial defect model Prevalence of lectures about dental esthetics and female speakers in three Brazilian conferences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1