{"title":"Measurement of Ankle Brachial Index with Oscillometric Method for Early Detection of Peripheral Artery Disease","authors":"E. Dewi, Gema Ramadhan, Robinsar Parlindungan, Lenny Iryani, Trisno Yuwono","doi":"10.17529/jre.v18i2.25758","DOIUrl":null,"url":null,"abstract":"Peripheral Arterial Disease (PAD) is a blood vessel disease caused by blockage or plaque accumulation around the artery walls. PAD is included in the category of diseases that are often diagnosed too late and affect more severe cases, such as the death of certain tissues or body parts. The Ankle Brachial Index (ABI) is an accurate non-invasive method for diagnosing PAD, in practice, ABI is usually performed in certain hospitals and is still difficult to find due to limited tools. Therefore, a tool is made that can detect the condition of a person's PAD based on the ABI value. The tool is made using two MPX5050GP sensors to detect oscillometric pulses, a DC pump and solenoid valve as an actuator to pump and deflate the cuff, ADS1115 as an external ADC to increase the accuracy of sensor readings, as well as an LCD and buzzer as tool indicators. The output is displayed in the form of a print out from a thermal printer, with an emergency stop that functions as a safety system to power off the supply when a failure occurs in the measurement process. Oscillometric method is used to detect systolic and diastolic pressure. The accuracy of the tool is 95.5%. This accuracy result is obtained by comparing the readings of systolic and diastolic values using a sphygmomanometer which is commonly used.","PeriodicalId":30766,"journal":{"name":"Jurnal Rekayasa Elektrika","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Rekayasa Elektrika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17529/jre.v18i2.25758","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Peripheral Arterial Disease (PAD) is a blood vessel disease caused by blockage or plaque accumulation around the artery walls. PAD is included in the category of diseases that are often diagnosed too late and affect more severe cases, such as the death of certain tissues or body parts. The Ankle Brachial Index (ABI) is an accurate non-invasive method for diagnosing PAD, in practice, ABI is usually performed in certain hospitals and is still difficult to find due to limited tools. Therefore, a tool is made that can detect the condition of a person's PAD based on the ABI value. The tool is made using two MPX5050GP sensors to detect oscillometric pulses, a DC pump and solenoid valve as an actuator to pump and deflate the cuff, ADS1115 as an external ADC to increase the accuracy of sensor readings, as well as an LCD and buzzer as tool indicators. The output is displayed in the form of a print out from a thermal printer, with an emergency stop that functions as a safety system to power off the supply when a failure occurs in the measurement process. Oscillometric method is used to detect systolic and diastolic pressure. The accuracy of the tool is 95.5%. This accuracy result is obtained by comparing the readings of systolic and diastolic values using a sphygmomanometer which is commonly used.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
示波法测量踝臂指数早期发现周围动脉疾病
外周动脉疾病(PAD)是一种由动脉壁堵塞或斑块积聚引起的血管疾病。PAD属于一类疾病,通常诊断太迟,影响更严重的病例,如某些组织或身体部位的死亡。踝臂指数(ABI)是诊断PAD的一种准确的非侵入性方法,在实践中,ABI通常在某些医院进行,由于工具有限,仍然很难找到。因此,制作了一种可以基于ABI值来检测人的PAD状况的工具。该工具使用两个MPX5050GP传感器来检测示波脉冲,一个直流泵和电磁阀作为致动器来泵送和放气袖带,ADS1115作为外部ADC来提高传感器读数的准确性,以及一个LCD和蜂鸣器作为工具指示器。输出以热敏打印机打印输出的形式显示,带有紧急停止功能,该功能作为安全系统,在测量过程中发生故障时关闭电源。示波法用于检测收缩压和舒张压。该工具的准确度为95.5%。该准确度结果是通过使用常用的血压计比较收缩压和舒张压的读数来获得的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
24
审稿时长
24 weeks
期刊最新文献
Impact of Segmentation and Popularity-based Cache Replacement Policies on Named Data Networking Real-Time Detection of Power Quality Disturbance Using Fast Fourier Transform and Adaptive Neuro-Fuzzy Inference System Wireless Photoplethysmography (PPG) Measurement with Pulse Wave Velocity (PWV) Method for Arterial Stiffness Evaluation Augmentation of Additional Arabic Dataset for Jawi Writing and Classification Using Deep Learning Anomaly Detection for Security in Children's Play Areas Based on Image Using Multiple Lines Detection Method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1