Venous dilation effect of hot towel (moist and dry heat) versus hot pack for peripheral intravenous catheterization: a quasi-experimental study.

IF 3.3 4区 医学 Q1 PHYSIOLOGY Journal of Physiological Anthropology Pub Date : 2023-10-19 DOI:10.1186/s40101-023-00340-5
Kae Yasuda, Inaho Shishido, Michito Murayama, Sanae Kaga, Rika Yano
{"title":"Venous dilation effect of hot towel (moist and dry heat) versus hot pack for peripheral intravenous catheterization: a quasi-experimental study.","authors":"Kae Yasuda, Inaho Shishido, Michito Murayama, Sanae Kaga, Rika Yano","doi":"10.1186/s40101-023-00340-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Heat application before peripheral intravenous catheterization is recommended for venous dilation. Hot pack application enlarges the venous diameter in healthy adults; however, hot towels (moist and dry heat) are used often in some medical cases. However, it is unclear whether hot towel application promotes venous dilation better than hot pack application. This study compared the venous dilation effect of using a hot towel (moist and dry heat) to a hot pack before applying the tourniquet at an access site for peripheral intravenous catheterization.</p><p><strong>Methods: </strong>Eighty-eight healthy females aged 18-29 years were recruited for this quasi-experimental study. They underwent three types of heat applications (hot pack, moist hot towel, and dry hot towel [moist hot towel wrapped in a dry plastic bag], all of which were warmed to 40 ± 2 °C and performed for 7 min) to their forearm and tourniquet application for 30 s after each heating. Venous diameter and depth were measured using ultrasonography, and venous palpability and visibility (venous assessment score) was observed as venous dilatation effects. In addition, the skin temperature, stratum corneum hydration, and subjective evaluation of the warmth were measured.</p><p><strong>Results: </strong>There were no significant differences in venous diameter and assessment scores after intervention between the dry hot towel and the hot pack groups, and the effect size was negligible (Cohen's d < 0.20). However, these measurements were significantly lower for the moist hot towel than for the other two heat applications (P < .001). Although there was no significant difference in skin temperature and warmth rating score between the dry hot towel and the hot pack, these were significantly lower for the moist hot towel than for the other two heat applications (P < .001). The amount of change in stratum corneum hydration of the dry hot towel was not significantly different from that of the hot pack; however, that of the moist hot towel was significantly larger than that of the other two heat applications (P < . 001.) CONCLUSIONS: A method in which a towel warmed in hot water is wrapped in a dry barrier may be an alternative to a hot pack.</p><p><strong>Trial registration: </strong>This study was registered with University Hospital Medical Information Network in Japan (Registration No.: UMIN000048308. Registered on July 7, 2022).</p>","PeriodicalId":48730,"journal":{"name":"Journal of Physiological Anthropology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2023-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10585830/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physiological Anthropology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40101-023-00340-5","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Heat application before peripheral intravenous catheterization is recommended for venous dilation. Hot pack application enlarges the venous diameter in healthy adults; however, hot towels (moist and dry heat) are used often in some medical cases. However, it is unclear whether hot towel application promotes venous dilation better than hot pack application. This study compared the venous dilation effect of using a hot towel (moist and dry heat) to a hot pack before applying the tourniquet at an access site for peripheral intravenous catheterization.

Methods: Eighty-eight healthy females aged 18-29 years were recruited for this quasi-experimental study. They underwent three types of heat applications (hot pack, moist hot towel, and dry hot towel [moist hot towel wrapped in a dry plastic bag], all of which were warmed to 40 ± 2 °C and performed for 7 min) to their forearm and tourniquet application for 30 s after each heating. Venous diameter and depth were measured using ultrasonography, and venous palpability and visibility (venous assessment score) was observed as venous dilatation effects. In addition, the skin temperature, stratum corneum hydration, and subjective evaluation of the warmth were measured.

Results: There were no significant differences in venous diameter and assessment scores after intervention between the dry hot towel and the hot pack groups, and the effect size was negligible (Cohen's d < 0.20). However, these measurements were significantly lower for the moist hot towel than for the other two heat applications (P < .001). Although there was no significant difference in skin temperature and warmth rating score between the dry hot towel and the hot pack, these were significantly lower for the moist hot towel than for the other two heat applications (P < .001). The amount of change in stratum corneum hydration of the dry hot towel was not significantly different from that of the hot pack; however, that of the moist hot towel was significantly larger than that of the other two heat applications (P < . 001.) CONCLUSIONS: A method in which a towel warmed in hot water is wrapped in a dry barrier may be an alternative to a hot pack.

Trial registration: This study was registered with University Hospital Medical Information Network in Japan (Registration No.: UMIN000048308. Registered on July 7, 2022).

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
外周静脉插管用热毛巾(湿热和干热)与热包的静脉扩张效果:一项准实验研究。
背景:建议在外周静脉导管插入术前加热进行静脉扩张。热敷可扩大健康成年人的静脉直径;然而,在某些医疗情况下,经常使用热毛巾(湿热和干热)。然而,目前尚不清楚使用热毛巾是否比使用热包更能促进静脉扩张。本研究比较了在外周静脉导管插入术的进入部位使用止血带之前,使用热毛巾(湿热)和热包的静脉扩张效果。方法:招募了88名18-29岁的健康女性参与这项准实验研究。他们接受了三种类型的加热应用(热包、湿热毛巾和干热毛巾(用干塑料袋包裹的湿热毛巾),所有这些都被加热到40 ± 2°C,持续7分钟),并在每次加热后使用止血带30秒。使用超声测量静脉直径和深度,并观察静脉可触摸性和可见性(静脉评估评分)作为静脉扩张效果。此外,还测量了皮肤温度、角质层水合作用和对温暖度的主观评价。结果:干热毛巾组和热包组在介入治疗后的静脉直径和评估得分方面没有显著差异,并且效果大小可以忽略不计(Cohen’s d 试验注册:本研究在日本大学医院医学信息网注册(注册号:UMIN000048308。于2022年7月7日注册)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
6.50%
发文量
39
期刊介绍: Journal of Physiological Anthropology (JPA) is an open access, peer-reviewed journal that publishes research on the physiological functions of modern mankind, with an emphasis on the physical and bio-cultural effects on human adaptability to the current environment. The objective of JPA is to evaluate physiological adaptations to modern living environments, and to publish research from different scientific fields concerned with environmental impact on human life. Topic areas include, but are not limited to: environmental physiology bio-cultural environment living environment epigenetic adaptation development and growth age and sex differences nutrition and morphology physical fitness and health Journal of Physiological Anthropology is the official journal of the Japan Society of Physiological Anthropology.
期刊最新文献
Effects of observing own/others hand movement in different perspectives on mu rhythm suppression: an EEG study. The impact of hygienic living conditions on the differentiation of male body height at the beginning of the twentieth century in the USSR. Association between thermogenic brown fat and genes under positive natural selection in circumpolar populations. Sustained metabolic dysregulation and the emergence of diabetes: associations between HbA1c and metabolic syndrome components in Tunisian diabetic and nondiabetic groups. Impact of high-altitude hypoxia on Helicobacter pylori-induced gastritis pathological manifestations and inflammatory responses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1