Comparison of Masimo Total Hemoglobin SpHb® continuous non-invasive hemoglobin monitoring device with laboratory complete blood count measurement using venous sample: Protocol for an observational substudy of the Pregnancy Risk and Infant Surveillance and Measurement Alliance Maternal and Newborn Health (PRISMA MNH) study.

Gates Open Research Pub Date : 2024-02-05 eCollection Date: 2023-01-01 DOI:10.12688/gatesopenres.14499.1
Fouzia Farooq, Emily R Smith, Qing Pan, Sasha Glass Baumann, Victor Akelo, Fyezah Jehan, Margaret Kasaro, Imran Nisar, Gregory Ouma, Bellington Vwalika, M Bridget Spelke, Joan T Price, Zahra Hoodbhoy
{"title":"Comparison of Masimo Total Hemoglobin SpHb® continuous non-invasive hemoglobin monitoring device with laboratory complete blood count measurement using venous sample: Protocol for an observational substudy of the Pregnancy Risk and Infant Surveillance and Measurement Alliance Maternal and Newborn Health (PRISMA MNH) study.","authors":"Fouzia Farooq, Emily R Smith, Qing Pan, Sasha Glass Baumann, Victor Akelo, Fyezah Jehan, Margaret Kasaro, Imran Nisar, Gregory Ouma, Bellington Vwalika, M Bridget Spelke, Joan T Price, Zahra Hoodbhoy","doi":"10.12688/gatesopenres.14499.1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Masimo Total Hemoglobin SpHb® is a continuous and non-invasive handheld device to measure hemoglobin levels. Previous research has found that SpHb is able to accurately detect hemoglobin levels in adult patients with a similar degree of bias and standard deviation to point-of-care invasive method measurements. Generally, limited clinical evidence, lack of validation of Masimo at higher than and lower than hemoglobin threshold values, and scientific consensus supporting the use of Masimo for accurate hemoglobin testing for the diagnosis of anemia during pregnancy calls for further research.</p><p><strong>Methods and analysis: </strong>The proposed prospective cohort will be nested within the ongoing Pregnancy Risk and Infant Surveillance and Measurement Alliance (PRISMA) Maternal and Newborn Health (MNH) study. Three study sites (located in Zambia, Kenya, and Pakistan) will participate and collect hemoglobin data at five time points (<20 weeks, 20 weeks, 28 weeks, 36 weeks' gestation, and six weeks postpartum). We will measure hemoglobin using a venous blood sample via hematology auto-analyzer complete blood count (gold standard) and the non-invasive device. The primary objective is to assess agreement between Masimo total hemoglobin and complete blood count and on a continuous scale using Intraclass Correlation Coefficient and Bland-Altman Analysis. The second objective is to assess agreement between the two measures on a binary scale using Positive Percentage Agreement and Negative Percentage Agreement, Cohen's Kappa, and McNemar Test. On an ordinal scale, agreement will be measured using Weighted Cohen's Kappa and Harrel's Concordance Index. Lastly, we will assess factors that might affect the accuracy of Masimo total hemoglobin using linear mixed models.</p><p><strong>Conclusions: </strong>The primary aim of this study is to assess the validity of the non-invasive Masimo device compared to the gold standard method of invasive hemoglobin measurements during pregnancy and postpartum periods for the diagnosis of anemia.</p>","PeriodicalId":12593,"journal":{"name":"Gates Open Research","volume":"7 ","pages":"50"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587393/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gates Open Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12688/gatesopenres.14499.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The Masimo Total Hemoglobin SpHb® is a continuous and non-invasive handheld device to measure hemoglobin levels. Previous research has found that SpHb is able to accurately detect hemoglobin levels in adult patients with a similar degree of bias and standard deviation to point-of-care invasive method measurements. Generally, limited clinical evidence, lack of validation of Masimo at higher than and lower than hemoglobin threshold values, and scientific consensus supporting the use of Masimo for accurate hemoglobin testing for the diagnosis of anemia during pregnancy calls for further research.

Methods and analysis: The proposed prospective cohort will be nested within the ongoing Pregnancy Risk and Infant Surveillance and Measurement Alliance (PRISMA) Maternal and Newborn Health (MNH) study. Three study sites (located in Zambia, Kenya, and Pakistan) will participate and collect hemoglobin data at five time points (<20 weeks, 20 weeks, 28 weeks, 36 weeks' gestation, and six weeks postpartum). We will measure hemoglobin using a venous blood sample via hematology auto-analyzer complete blood count (gold standard) and the non-invasive device. The primary objective is to assess agreement between Masimo total hemoglobin and complete blood count and on a continuous scale using Intraclass Correlation Coefficient and Bland-Altman Analysis. The second objective is to assess agreement between the two measures on a binary scale using Positive Percentage Agreement and Negative Percentage Agreement, Cohen's Kappa, and McNemar Test. On an ordinal scale, agreement will be measured using Weighted Cohen's Kappa and Harrel's Concordance Index. Lastly, we will assess factors that might affect the accuracy of Masimo total hemoglobin using linear mixed models.

Conclusions: The primary aim of this study is to assess the validity of the non-invasive Masimo device compared to the gold standard method of invasive hemoglobin measurements during pregnancy and postpartum periods for the diagnosis of anemia.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Masimo总血红蛋白SpHb®连续无创血红蛋白监测设备与使用静脉样本的实验室全血细胞计数测量的比较:妊娠风险和婴儿监测与测量联盟母婴健康(PRISMA MNH)研究的观察性亚研究方案。
背景:Masimo Total Hemoglobin SpHb®是一种用于测量血红蛋白水平的连续无创手持设备。先前的研究发现,SpHb能够准确检测成年患者的血红蛋白水平,其偏差和标准偏差与护理点侵入性方法测量的偏差和标准差相似。一般来说,临床证据有限,Masimo在高于和低于血红蛋白阈值时缺乏验证,以及支持使用Masimo进行准确的血红蛋白检测以诊断妊娠期贫血的科学共识,都需要进一步研究。方法和分析:拟议的前瞻性队列将嵌套在正在进行的妊娠风险和婴儿监测与测量联盟(PRISMA)母婴健康(MNH)研究中。三个研究地点(位于赞比亚、肯尼亚和巴基斯坦)将参与并收集五个时间点的血红蛋白数据(结论:本研究的主要目的是评估无创Masimo设备与妊娠期和产后有创血红蛋白测量金标准方法相比诊断贫血的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Gates Open Research
Gates Open Research Immunology and Microbiology-Immunology and Microbiology (miscellaneous)
CiteScore
3.60
自引率
0.00%
发文量
90
期刊最新文献
Developing a framework for understanding policy decision-making behaviors in the transition of an HIV prevention program towards sustainability: a case study from Zambia's voluntary medical male circumcision program. Knowledge and uptake of contraceptive and other sexual reproductive health services among in-school adolescents in three South African townships: Baseline findings from the Girls Achieve Power (GAP Year) Trial. Using models and maps to inform Target Product Profiles and Preferred Product Characteristics: the example of Wolbachia replacement. Vaccine decision-making among pregnant women: a protocol for a cross-sectional mixed-method study in Brazil, Ghana, Kenya and Pakistan. Simulated data for census-scale entity resolution research without privacy restrictions: a large-scale dataset generated by individual-based modeling.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1