{"title":"Monocyte/High-Density Lipoprotein Ratio Is Associated with Atrial High-Rate Episodes within One Year Detected by Cardiac Implantable Electronic Devices.","authors":"Lishuang Ji,&nbsp;Le Wang,&nbsp;Xuecheng Song,&nbsp;Mei Wei,&nbsp;Min Li,&nbsp;Mingqi Zheng,&nbsp;Gang Liu","doi":"10.21470/1678-9741-2023-0144","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the risk factors for predicting atrial high-rate episodes (AHREs) detected by cardiac implantable electronic devices (CIEDs).</p><p><strong>Methods: </strong>A total of 140 patients with CIED in our hospital from June 2013 to June 2018 were included and were followed up to observe whether they had AHREs. AHRE are defined as atrial rate ≥ 175 times/minute, lasting > 5 minutes, and reviewed by an experienced electrophysiologist with unclear clinical diagnosis. The patients fasted for 12 hours after implantation, and blood samples were collected for biochemical, lipid, and whole blood count detection. Follow-up was regular after discharge to record follow-up data of each patient and conduct statistical analysis.</p><p><strong>Results: </strong>One hundred and forty patients were implanted with dual-chamber pacemakers, their median age was 70 years old, 44.29% were male, 27 patients had AHRE within one year, and AHRE incidence rate was 19.29%. The microcytic to hypochromic (M/H) ratio was calculated for all AHRE patients and compared with the patients without AHRE; the M/H value of AHRE patients was significantly higher. Throughout the entire follow-up period, a total of 44 patients developed AHRE; when adjusted by multivariate analysis, only M/H ratio ≥ 4.5 vs. < 4.5 had statistical significance, and the adjusted hazard ratio value was 4.313 (1.675-11.105).</p><p><strong>Conclusion: </strong>As an indicator, M/H ratio may play an important role in the occurrence and development of atrial fibrillation and can be used as a predictor of AHRE in patients with CIED.</p>","PeriodicalId":72457,"journal":{"name":"Brazilian journal of cardiovascular surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10593409/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian journal of cardiovascular surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21470/1678-9741-2023-0144","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the risk factors for predicting atrial high-rate episodes (AHREs) detected by cardiac implantable electronic devices (CIEDs).

Methods: A total of 140 patients with CIED in our hospital from June 2013 to June 2018 were included and were followed up to observe whether they had AHREs. AHRE are defined as atrial rate ≥ 175 times/minute, lasting > 5 minutes, and reviewed by an experienced electrophysiologist with unclear clinical diagnosis. The patients fasted for 12 hours after implantation, and blood samples were collected for biochemical, lipid, and whole blood count detection. Follow-up was regular after discharge to record follow-up data of each patient and conduct statistical analysis.

Results: One hundred and forty patients were implanted with dual-chamber pacemakers, their median age was 70 years old, 44.29% were male, 27 patients had AHRE within one year, and AHRE incidence rate was 19.29%. The microcytic to hypochromic (M/H) ratio was calculated for all AHRE patients and compared with the patients without AHRE; the M/H value of AHRE patients was significantly higher. Throughout the entire follow-up period, a total of 44 patients developed AHRE; when adjusted by multivariate analysis, only M/H ratio ≥ 4.5 vs. < 4.5 had statistical significance, and the adjusted hazard ratio value was 4.313 (1.675-11.105).

Conclusion: As an indicator, M/H ratio may play an important role in the occurrence and development of atrial fibrillation and can be used as a predictor of AHRE in patients with CIED.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单核细胞/高密度脂蛋白比率与心脏植入电子设备检测到的一年内心房高发病率有关。
目的:探讨预测心脏植入式电子设备(CIED)检测到的心房高频率发作(AHRE)的危险因素。方法:纳入2013年6月至2018年6月在我院就诊的140例CIED患者,随访观察他们是否患有AHRE。AHRE定义为心房频率≥175次/分钟,持续时间>5分钟,由经验丰富的电生理学家进行审查,但临床诊断不明确。患者在植入后禁食12小时,并采集血样进行生化、脂质和全血计数检测。出院后定期随访,记录每位患者的随访数据并进行统计分析。结果:140例患者植入双腔起搏器,中位年龄70岁,男性44.29%,1年内发生AHRE 27例,AHRE发生率19.29%;AHRE患者的M/H值明显较高。在整个随访期间,共有44名患者出现AHRE;经多元分析校正后,只有M/H比值≥4.5与<4.5具有统计学意义,校正后的危险比值为4.313(1.675-11.105)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Usefulness of Microcirculatory Assessment After Cardiac Surgery: Illustrative Case Report. Risk Model for Laryngeal Complications Prediction in Chinese PatientGBVs After Coronary Artery Bypass Grafting. Artificial Intelligence in the Hands of Perfusionists: Revolutionizing Cardiopulmonary Bypass. Assessment of EuroSCORE II and STS Score Performance and the Impact of Surgical Urgency in Isolated Coronary Artery Bypass Graft Surgery at a Referral Center in São Paulo, Brazil. Comparison of the Effect of Pump Flow Type (Pulsatile or Non-Pulsatile) on Postoperative Neurocognitive Functions in Coronary Artery Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1