MENISCAL EXTRUSION IN ASYMPTOMATIC KNEES: THE 3MM CUTOFF MUST BE REVISITED

S. Zenkhri , P. Margain , J. Favre , P. Omoumi , C. Mourad
{"title":"MENISCAL EXTRUSION IN ASYMPTOMATIC KNEES: THE 3MM CUTOFF MUST BE REVISITED","authors":"S. Zenkhri ,&nbsp;P. Margain ,&nbsp;J. Favre ,&nbsp;P. Omoumi ,&nbsp;C. Mourad","doi":"10.1016/j.ostima.2023.100136","DOIUrl":null,"url":null,"abstract":"<div><h3>INTRODUCTION</h3><p>Meniscal extrusion is frequently encountered in OA, and an arbitrary cutoff value of 3 mm is commonly accepted for a significant extrusion of the body of the medial meniscus (MM). Different methods of measurement have also been described.</p></div><div><h3>OBJECTIVE</h3><p>We aim to provide the normal range of MM extrusion in different zones in asymptomatic volunteers without radiographic and/or MRI OA and to compare different measurement methods on coronal and sagittal 2D images to those performed on 3D images in radial planes.</p></div><div><h3>METHODS</h3><p>This is a post-hoc analysis of knee MRIs of 93 participants (39.6±16.0 years; mean ± SD) with asymptomatic, healthy knees (KOOS score 97.42±3.22 and WOMAC score 97.41±7.54) from the Lausanne Knee Study. Inclusion criteria: age between 18-35 or 45-70 years, no knee symptoms in the past 12 months, no history of severe lower limb injury, no impairment that might affect gait, BMI≤30. Imaging protocol included weight-bearing Schuss and lateral radiographs of both knees and 3T MRI of a randomly selected knee. MRI protocol included 2D fat-suppressed FSE IW images (sagittal, coronal, and transverse planes), isotropic 3D DESS, and high-resolution 3D T1. One radiologist measured the maximal extrusion of the MM in the radial plane using 3D FSE T1 images in 4 anatomical subregions: zones II-a (anterior), II-b (anteromedial), III (medial), and IV (posterior). Measurements were also performed on coronal and sagittal 2D images using two different methods: on the image where the maximal extrusion was seen (method<sup>Max</sup>) and on an image selected based on anatomical landmarks (method<sup>Landmark</sup>). Another musculoskeletal radiologist graded knee MRIs for all structural lesions included in the MOAKS criteria. In addition, meniscal extrusion was measured in the sagittal and radial planes to assess interobserver agreement. Measurements on 2D images were compared to those on the radial plane, considered as the reference, using the Bland and Altman method. Sixty-one (65.5%) participants (41.4±16.6 years) who did not have either radiographic OA (KL&lt;2) or MRI-OA (Hunter 2011 criteria) were used to provide the normal range of meniscal extrusion.</p></div><div><h3>RESULTS</h3><p>Among the 61 participants without radiographic or MRI OA, the mean extrusion of MM was 2.39mm±1.41 (zone II-a), 3mm±0.85 (zone II-b), 2.4mm±0.81 (zone III), and 0.3mm±0.9 (zone IV). The 95<sup>th</sup> percentile of the reference interval for meniscal extrusion in the radial plane was 4.7mm for zone II-a, 4.4mm (zone II-b), 3.7mm (zone III), and 2mm (zone IV).</p><p>By applying a cutoff value of &gt;3mm for significant meniscal extrusion on measurements in the radial plane, 28/61 (46%) would have been categorized as having extrusion in zone II-b and 12/61 (20%) in zone III. In the coronal plane, 13/61 (21%) or 18/61 (30%) would have been categorized as having meniscal extrusion depending on whether measurements were performed using method<sup>Landmark</sup>, or method<sup>Max</sup> respectively.</p><p>In both sagittal and coronal planes, method<sup>Max</sup> overestimated meniscal extrusion (95%CI for systematic bias=0.5, 1 in the sagittal plan, 0.1, 0.3 in the coronal plane), while there was no systematic bias for method<sup>Landmark</sup>. The width of limits of agreement was similar in both planes and for both methods. Interobserver agreement was moderate for measurements in the radial (ICC=0.67) and sagittal (0.68) plane.</p></div><div><h3>CONCLUSION</h3><p>This study provided the normal range of meniscal extrusion in asymptomatic knees without radiographic/MRI OA. Applying a 3mm cutoff value for the diagnosis of significant meniscal extrusion would carry a risk to categorize normal menisci as being extruded. Methods of measurement based on anatomical landmarks correlated better with measurements in the radial plane.</p></div><div><h3>SPONSOR</h3><p>This work was supported by the Swiss National Science Foundation, Switzerland (SNSF Grant #CRSII5_177155).</p></div><div><h3>DICLOSURE STATEMENT</h3><p>None to declare.</p><p>CORRESPONDENCE ADDRESS: <span><span>[email protected]</span></span><svg><path></path></svg></p></div>","PeriodicalId":74378,"journal":{"name":"Osteoarthritis imaging","volume":"3 ","pages":"Article 100136"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Osteoarthritis imaging","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S277265412300051X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

INTRODUCTION

Meniscal extrusion is frequently encountered in OA, and an arbitrary cutoff value of 3 mm is commonly accepted for a significant extrusion of the body of the medial meniscus (MM). Different methods of measurement have also been described.

OBJECTIVE

We aim to provide the normal range of MM extrusion in different zones in asymptomatic volunteers without radiographic and/or MRI OA and to compare different measurement methods on coronal and sagittal 2D images to those performed on 3D images in radial planes.

METHODS

This is a post-hoc analysis of knee MRIs of 93 participants (39.6±16.0 years; mean ± SD) with asymptomatic, healthy knees (KOOS score 97.42±3.22 and WOMAC score 97.41±7.54) from the Lausanne Knee Study. Inclusion criteria: age between 18-35 or 45-70 years, no knee symptoms in the past 12 months, no history of severe lower limb injury, no impairment that might affect gait, BMI≤30. Imaging protocol included weight-bearing Schuss and lateral radiographs of both knees and 3T MRI of a randomly selected knee. MRI protocol included 2D fat-suppressed FSE IW images (sagittal, coronal, and transverse planes), isotropic 3D DESS, and high-resolution 3D T1. One radiologist measured the maximal extrusion of the MM in the radial plane using 3D FSE T1 images in 4 anatomical subregions: zones II-a (anterior), II-b (anteromedial), III (medial), and IV (posterior). Measurements were also performed on coronal and sagittal 2D images using two different methods: on the image where the maximal extrusion was seen (methodMax) and on an image selected based on anatomical landmarks (methodLandmark). Another musculoskeletal radiologist graded knee MRIs for all structural lesions included in the MOAKS criteria. In addition, meniscal extrusion was measured in the sagittal and radial planes to assess interobserver agreement. Measurements on 2D images were compared to those on the radial plane, considered as the reference, using the Bland and Altman method. Sixty-one (65.5%) participants (41.4±16.6 years) who did not have either radiographic OA (KL<2) or MRI-OA (Hunter 2011 criteria) were used to provide the normal range of meniscal extrusion.

RESULTS

Among the 61 participants without radiographic or MRI OA, the mean extrusion of MM was 2.39mm±1.41 (zone II-a), 3mm±0.85 (zone II-b), 2.4mm±0.81 (zone III), and 0.3mm±0.9 (zone IV). The 95th percentile of the reference interval for meniscal extrusion in the radial plane was 4.7mm for zone II-a, 4.4mm (zone II-b), 3.7mm (zone III), and 2mm (zone IV).

By applying a cutoff value of >3mm for significant meniscal extrusion on measurements in the radial plane, 28/61 (46%) would have been categorized as having extrusion in zone II-b and 12/61 (20%) in zone III. In the coronal plane, 13/61 (21%) or 18/61 (30%) would have been categorized as having meniscal extrusion depending on whether measurements were performed using methodLandmark, or methodMax respectively.

In both sagittal and coronal planes, methodMax overestimated meniscal extrusion (95%CI for systematic bias=0.5, 1 in the sagittal plan, 0.1, 0.3 in the coronal plane), while there was no systematic bias for methodLandmark. The width of limits of agreement was similar in both planes and for both methods. Interobserver agreement was moderate for measurements in the radial (ICC=0.67) and sagittal (0.68) plane.

CONCLUSION

This study provided the normal range of meniscal extrusion in asymptomatic knees without radiographic/MRI OA. Applying a 3mm cutoff value for the diagnosis of significant meniscal extrusion would carry a risk to categorize normal menisci as being extruded. Methods of measurement based on anatomical landmarks correlated better with measurements in the radial plane.

SPONSOR

This work was supported by the Swiss National Science Foundation, Switzerland (SNSF Grant #CRSII5_177155).

DICLOSURE STATEMENT

None to declare.

CORRESPONDENCE ADDRESS: [email protected]

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
无症状膝关节的半月板挤压:3mm的截距必须重新检查
引言半月板挤出在OA中经常遇到,对于内侧半月板(mm)的主体的显著挤出,通常接受3mm的任意截止值。还描述了不同的测量方法。目的:我们旨在提供无放射学和/或MRI OA的无症状志愿者不同区域MM挤出的正常范围,并比较冠状面和矢状面2D图像与放射面3D图像的不同测量方法。方法这是对洛桑膝关节研究中93名无症状、健康膝关节(KOOS评分97.42±3.22,WOMAC评分97.41±7.54)参与者(39.6±16.0岁;平均值±SD)的膝关节MRI的事后分析。纳入标准:年龄在18-35岁或45-70岁之间,过去12个月内没有膝盖症状,没有严重下肢损伤史,没有可能影响步态的损伤,BMI≤30。成像方案包括两膝的负重Schuss和侧位X线片,以及随机选择的膝关节的3T MRI。MRI方案包括2D脂肪抑制FSE IW图像(矢状面、冠状面和横切面)、各向同性3D DESS和高分辨率3D T1。一位放射科医生使用3D FSE T1图像测量了4个解剖亚区(II-a区(前部)、II-b区(前内侧)、III区(内侧)和IV区(后部)的MM在径向平面内的最大挤压。还使用两种不同的方法对冠状面和矢状面2D图像进行了测量:在看到最大挤压的图像上(methodMax)和在根据解剖标志选择的图像(methodLandmark)。另一位肌肉骨骼放射科医生对MOAKS标准中包括的所有结构损伤进行了膝关节MRI分级。此外,在矢状面和径向面测量半月板挤压,以评估观察者之间的一致性。使用Bland和Altman方法,将2D图像上的测量值与作为参考的径向平面上的测量结果进行比较。61名(65.5%)参与者(41.4±16.6岁)没有放射学OA(KL<;2)或MRI-OA(Hunter 2011标准),用于提供半月板挤压的正常范围。结果在61名未经影像学或MRI检查的OA患者中,MM的平均挤出量分别为2.39mm±1.41(II-a区)、3mm±0.85(II-b区)、2.4mm±0.81(III区)和0.3mm±0.9(IV区)。第95届 在径向平面内半月板挤压的参考间隔的百分位数为4.7mm(区域II-a)、4.4mm(区域II.b)、3.7mm(区域III)和2mm(区域IV)。通过应用>;在径向平面的测量中,对于显著的半月板挤压3mm,28/61(46%)将被归类为在II-b区有挤压,12/61(20%)将被分类为在III区有挤压。在冠状平面中,13/61(21%)或18/61(30%)将被归为半月板挤压,这取决于分别使用方法Landmark或方法Max进行测量。在矢状面和冠状面,methodMax高估了半月板挤压(系统偏差的95%置信区间=0.5,矢状面为1,冠状面为0.1,0.3),而methodLandmark没有系统偏差。在两个平面和两种方法中,一致界限的宽度相似。在径向(ICC=0.67)和矢状面(0.68)的测量中,观察者之间的一致性是中等的。结论本研究提供了无症状膝关节骨性关节炎患者半月板挤压的正常范围。应用3mm的截止值来诊断严重半月板挤压将有风险将正常半月板归类为挤压。 基于解剖标志的测量方法与径向平面中的测量更好地相关。赞助商这项工作得到了瑞士国家科学基金会(SNSF Grant#CRSII5_177155)的支持。DICLOSURE STATEMENT无需声明。通讯地址:〔email protected〕
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Osteoarthritis imaging
Osteoarthritis imaging Radiology and Imaging
自引率
0.00%
发文量
0
期刊最新文献
Trapeziometacarpal joint movement during pinching measured by ultrasonography Standardized maps – an emerging approach to leverage quantitative information in knee imaging 3D bone shape from CT-scans provides an objective measure of osteoarthritis severity: Data from the IMI-APPROACH study Weight bearing 3-D joint space width distribution at the knee varies according to location and extent of meniscal extrusion: A MOST investigation Front Cover
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1