Variación de los parámetros acústicos: f0, Jitter, Shimmer y Alpha ratio en relación con distintos niveles de ruido de fondo

IF 0.9 Q3 OTORHINOLARYNGOLOGY Acta otorrinolaringologica espanola Pub Date : 2023-07-01 DOI:10.1016/j.otorri.2022.06.003
María José Marsano-Cornejo , Ángel Roco-Videla
{"title":"Variación de los parámetros acústicos: f0, Jitter, Shimmer y Alpha ratio en relación con distintos niveles de ruido de fondo","authors":"María José Marsano-Cornejo ,&nbsp;Ángel Roco-Videla","doi":"10.1016/j.otorri.2022.06.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and objectives</h3><p>Research involving acoustic analysis does not always consider the level of background noise in the room where the recording process is going to be carried out, or if they do, the maximum value of background noise used varies from author to author. The objective of this research is to establish if the parameters: f<sub>0</sub>, Jitter, Shimmer and Alpha ratio vary in relation to different levels of background noise in the room where the recording process is carried out and to establish a maximum value of this.</p></div><div><h3>Materials and methods</h3><p>The Praat program was used to get the average value of the parameters: f<sub>0</sub>, Jitter, Shimmer and Alpha ratio from a voice sample of 33 subjects inside an audiometric booth whose background noise level was 28.1<!--> <!-->dB(A). A statistical comparison was made between the average value of each parameter as the background noise increased in relation to the average values obtained with the baseline background noise of the cabin for each parameter.</p></div><div><h3>Results</h3><p>The f<sub>0</sub> and Alpha ratio parameters show reliable values up to a background noise level of 47.7<!--> <!-->dB(A), while the Jitter and Shimmer parameters do so up to a background noise level of 43.8<!--> <!-->dB(A).</p></div><div><h3>Conclusions</h3><p>Considering that the acoustic parameters are all obtained from the same recording, we can point out that the recommended maximum background noise level in the room where the recordings are made should not exceed 43.8<!--> <!-->dB(A).</p></div>","PeriodicalId":7019,"journal":{"name":"Acta otorrinolaringologica espanola","volume":"74 4","pages":"Pages 219-225"},"PeriodicalIF":0.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta otorrinolaringologica espanola","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0001651922001157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives

Research involving acoustic analysis does not always consider the level of background noise in the room where the recording process is going to be carried out, or if they do, the maximum value of background noise used varies from author to author. The objective of this research is to establish if the parameters: f0, Jitter, Shimmer and Alpha ratio vary in relation to different levels of background noise in the room where the recording process is carried out and to establish a maximum value of this.

Materials and methods

The Praat program was used to get the average value of the parameters: f0, Jitter, Shimmer and Alpha ratio from a voice sample of 33 subjects inside an audiometric booth whose background noise level was 28.1 dB(A). A statistical comparison was made between the average value of each parameter as the background noise increased in relation to the average values obtained with the baseline background noise of the cabin for each parameter.

Results

The f0 and Alpha ratio parameters show reliable values up to a background noise level of 47.7 dB(A), while the Jitter and Shimmer parameters do so up to a background noise level of 43.8 dB(A).

Conclusions

Considering that the acoustic parameters are all obtained from the same recording, we can point out that the recommended maximum background noise level in the room where the recordings are made should not exceed 43.8 dB(A).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
声学参数的变化:与不同背景噪声水平相关的F0、Jitter、Shimmer和Alpha比
背景和目的涉及声学分析的研究并不总是考虑将要进行录音过程的房间中的背景噪声水平,或者如果考虑了,所使用的背景噪声的最大值因作者而异。本研究的目的是确定参数f0、抖动、Shimmer和Alpha比率是否随录音室中不同水平的背景噪声而变化,并确定其最大值。材料与方法用Praat程序求出f0、Jitter、,在背景噪声水平为28.1dB(a)的听力测量室内,33名受试者的声音样本的Shimmer和Alpha比率。随着背景噪声的增加,每个参数的平均值与每个参数的客舱基线背景噪声平均值进行了统计比较。结果f0和Alpha比参数在背景噪声水平为47.7 dB(a)时表现出可靠的值,而Jitter和Shimmer参数在背景噪音水平为43.8 dB(a,我们可以指出,在进行录音的房间中,建议的最大背景噪声水平不应超过43.8dB(A)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.40
自引率
20.00%
发文量
44
审稿时长
44 days
期刊介绍: Es la revista más importante en español dedicada a la especialidad. Ofrece progresos científicos y técnicos tanto a nivel de originales como de casos clínicos. Además, es la Publicación Oficial de la Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial y está presente en los más prestigiosos índices de referencia.
期刊最新文献
Retrolabyrinthine approach to the lateral skull base: The value of preoperative temporal bone CT analysis Situación actual de la tutoría en la formación especializada en otorrinolaringología en España. ¿Dónde estamos? ¿Hacia dónde queremos ir? Prevalencia de apnea obstructiva del sueño en pacientes obesos candidatos a cirugía bariátrica y cuestionarios predictores Recurrent peritonsillar abscess in adults: Incidence and risk factors in a prospective longitudinal cohort Enhancing the coverage and rotation of anterior ethmoidal artery flap for septal perforation closure: Insights from a flap design study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1