{"title":"PWM methods to handle time delay in digital control of a UPS inverter","authors":"Heng Deng;R. Oruganti;D. Srinivasan","doi":"10.1109/LPEL.2004.842402","DOIUrl":null,"url":null,"abstract":"With the popularity of micro-processors, digital controllers are widely used in uninterruptible power supply (UPS) inverters. These digital control systems of UPS inverters require a time interval for sampling and computation, which sometimes affects the performance of inverters. In this paper, the problem of time delay in digital control of a UPS inverter is discussed. Then two novel pulsewidth modulation (PWM) methods, the two-polarity PWM method and the asymmetric PWM method, are proposed to handle the time-delay problem. Both of these PWM methods can achieve a wide range of duty ratio between 0.05-0.95, which is independent of inverter model. Furthermore, they are easy to implement using a digital micro-controller. Experimental results are presented in the paper to verify feasibility of the proposed PWM methods.","PeriodicalId":100635,"journal":{"name":"IEEE Power Electronics Letters","volume":"3 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2005-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/LPEL.2004.842402","citationCount":"69","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Electronics Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/1411770/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 69
Abstract
With the popularity of micro-processors, digital controllers are widely used in uninterruptible power supply (UPS) inverters. These digital control systems of UPS inverters require a time interval for sampling and computation, which sometimes affects the performance of inverters. In this paper, the problem of time delay in digital control of a UPS inverter is discussed. Then two novel pulsewidth modulation (PWM) methods, the two-polarity PWM method and the asymmetric PWM method, are proposed to handle the time-delay problem. Both of these PWM methods can achieve a wide range of duty ratio between 0.05-0.95, which is independent of inverter model. Furthermore, they are easy to implement using a digital micro-controller. Experimental results are presented in the paper to verify feasibility of the proposed PWM methods.