Jacob Mulder, Graham Hagen-Peter, Teresa Ubide, Rasmus Andreasen, Ellen Kooijman, Melanie Kielman-Schmitt, Yue-Xing Feng, Bence Paul, Andreas Karlsson, Christian Tegner, Charles Lesher, Fidel Costa
{"title":"New Reference Materials, Analytical Procedures and Data Reduction Strategies for Sr Isotope Measurements in Geological Materials by LA-MC-ICP-MS","authors":"Jacob Mulder, Graham Hagen-Peter, Teresa Ubide, Rasmus Andreasen, Ellen Kooijman, Melanie Kielman-Schmitt, Yue-Xing Feng, Bence Paul, Andreas Karlsson, Christian Tegner, Charles Lesher, Fidel Costa","doi":"10.1111/ggr.12480","DOIUrl":null,"url":null,"abstract":"<p>Laser ablation multi-collector mass spectrometry (LA-MC-ICP-MS) has emerged as the technique of choice for <i>in situ</i> measurements of Sr isotopes in geological minerals. However, the method poses analytical challenges and there is no widely adopted standardised approach to collecting these data or correcting the numerous potential isobaric inferences. Here, we outline practical analytical procedures and data reduction strategies to help establish a consistent framework for collecting and correcting Sr isotope measurements in geological materials by LA-MC-ICP-MS. We characterise a new set of plagioclase reference materials, which are available for distribution to the community, and present a new data reduction scheme for the <i>Iolite</i> software package to correct isobaric interferences for different materials and analytical conditions. Our tests show that a combination of Kr-baseline subtraction, Rb-peak-stripping using βRb derived from a bracketing glass reference material, and a CaCa or CaAr correction for plagioclase and CaCa or CaAr + REE<sup>2+</sup> correction for rock glasses, yields the most accurate and precise <sup>87</sup>Sr/<sup>86</sup>Sr measurements for these materials. Using the analytical and correction procedures outlined herein, spot analyses using a beam diameter of 100 μm or rastering with a 50–65 μm diameter beam can readily achieve < 100 ppm 2SE repeatability (\"internal\") precision for <sup>87</sup>Sr/<sup>86</sup>Sr measurements for materials with < 1000 μg g<sup>-1</sup> Sr.</p>","PeriodicalId":12631,"journal":{"name":"Geostandards and Geoanalytical Research","volume":"47 2","pages":"311-336"},"PeriodicalIF":2.7000,"publicationDate":"2023-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ggr.12480","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geostandards and Geoanalytical Research","FirstCategoryId":"89","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ggr.12480","RegionNum":2,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
引用次数: 1
Abstract
Laser ablation multi-collector mass spectrometry (LA-MC-ICP-MS) has emerged as the technique of choice for in situ measurements of Sr isotopes in geological minerals. However, the method poses analytical challenges and there is no widely adopted standardised approach to collecting these data or correcting the numerous potential isobaric inferences. Here, we outline practical analytical procedures and data reduction strategies to help establish a consistent framework for collecting and correcting Sr isotope measurements in geological materials by LA-MC-ICP-MS. We characterise a new set of plagioclase reference materials, which are available for distribution to the community, and present a new data reduction scheme for the Iolite software package to correct isobaric interferences for different materials and analytical conditions. Our tests show that a combination of Kr-baseline subtraction, Rb-peak-stripping using βRb derived from a bracketing glass reference material, and a CaCa or CaAr correction for plagioclase and CaCa or CaAr + REE2+ correction for rock glasses, yields the most accurate and precise 87Sr/86Sr measurements for these materials. Using the analytical and correction procedures outlined herein, spot analyses using a beam diameter of 100 μm or rastering with a 50–65 μm diameter beam can readily achieve < 100 ppm 2SE repeatability ("internal") precision for 87Sr/86Sr measurements for materials with < 1000 μg g-1 Sr.
期刊介绍:
Geostandards & Geoanalytical Research is an international journal dedicated to advancing the science of reference materials, analytical techniques and data quality relevant to the chemical analysis of geological and environmental samples. Papers are accepted for publication following peer review.