Gram staining of the preoperative joint aspiration for the diagnosis of infection after total knee arthroplasty

Yasuo Kunugiza , Masashi Tamaki , Takashi Miyamoto , Shigeyoshi Tsuji , Koichiro Takahi , Masataka Nishikawa , Ayanori Yoshida , Koji Nomura , Keiji Iwamoto , Toshitaka Fujito , Kentaro Toge , Teruya Ishibashi , Seiji Okada , Tetsuya Tomita
{"title":"Gram staining of the preoperative joint aspiration for the diagnosis of infection after total knee arthroplasty","authors":"Yasuo Kunugiza ,&nbsp;Masashi Tamaki ,&nbsp;Takashi Miyamoto ,&nbsp;Shigeyoshi Tsuji ,&nbsp;Koichiro Takahi ,&nbsp;Masataka Nishikawa ,&nbsp;Ayanori Yoshida ,&nbsp;Koji Nomura ,&nbsp;Keiji Iwamoto ,&nbsp;Toshitaka Fujito ,&nbsp;Kentaro Toge ,&nbsp;Teruya Ishibashi ,&nbsp;Seiji Okada ,&nbsp;Tetsuya Tomita","doi":"10.1016/j.jjoisr.2023.07.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>Gram staining of joint fluid for the diagnosis of postoperative joint infection after total knee arthroplasty is considered to have limited efficacy because of the low sensitivity. However, the specificity of the gram staining is reported to be high in most reports. This study aimed to evaluate the sensitivity and specificity of the gram staining when used on the aspirated joint fluid in patients with suspected postoperative knee joint infection after total knee arthroplasty.</p></div><div><h3>Methods</h3><p>We retrospectively reviewed the reports of synovial fluid samples retrieved from suspected infected joints at eight hospitals between 2012 and 2019. A total of 179 samples of aspirated joint fluid from knee joints (80 culture-positive samples and 99 culture-negative samples) were evaluated in this study.</p></div><div><h3>Results</h3><p>Of the 80 gram stains performed on samples from infected patients, there were 60 true positives and 20 false negatives. In contrast, of the 99 stains performed on samples from aseptic knees, there were 99 true negatives and no false positives. The sensitivity and specificity for detecting periprosthetic knee infections were 75.0% and 100.0%, respectively. Further, we divided infected samples into the early aspiration group (within 14 days) and the late aspiration group (15 days or more) based on the duration between the onset of symptoms and aspiration. The sensitivity of the gram staining was 84.2% and 41.2% in the first and second groups, respectively.</p></div><div><h3>Conclusions</h3><p>In this study, gram staining of preoperatively aspirated joint fluid for the infected periprosthetic knee joint with short-lived symptoms showed high sensitivity.</p></div>","PeriodicalId":100795,"journal":{"name":"Journal of Joint Surgery and Research","volume":"2 ","pages":"Pages 175-178"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2949705123000245/pdfft?md5=44b38f6c2828ad122957d2e1ef340181&pid=1-s2.0-S2949705123000245-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Joint Surgery and Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949705123000245","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Gram staining of joint fluid for the diagnosis of postoperative joint infection after total knee arthroplasty is considered to have limited efficacy because of the low sensitivity. However, the specificity of the gram staining is reported to be high in most reports. This study aimed to evaluate the sensitivity and specificity of the gram staining when used on the aspirated joint fluid in patients with suspected postoperative knee joint infection after total knee arthroplasty.

Methods

We retrospectively reviewed the reports of synovial fluid samples retrieved from suspected infected joints at eight hospitals between 2012 and 2019. A total of 179 samples of aspirated joint fluid from knee joints (80 culture-positive samples and 99 culture-negative samples) were evaluated in this study.

Results

Of the 80 gram stains performed on samples from infected patients, there were 60 true positives and 20 false negatives. In contrast, of the 99 stains performed on samples from aseptic knees, there were 99 true negatives and no false positives. The sensitivity and specificity for detecting periprosthetic knee infections were 75.0% and 100.0%, respectively. Further, we divided infected samples into the early aspiration group (within 14 days) and the late aspiration group (15 days or more) based on the duration between the onset of symptoms and aspiration. The sensitivity of the gram staining was 84.2% and 41.2% in the first and second groups, respectively.

Conclusions

In this study, gram staining of preoperatively aspirated joint fluid for the infected periprosthetic knee joint with short-lived symptoms showed high sensitivity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
术前关节抽吸革兰氏染色诊断全膝关节置换术后感染
目的关节液革兰氏染色诊断全膝关节置换术后关节感染由于敏感性低,疗效有限。然而,据报道,在大多数报告中,革兰氏染色的特异性很高。本研究旨在评估全膝关节置换术后疑似膝关节感染患者在抽吸关节液时使用革兰氏染色的敏感性和特异性。方法我们回顾性回顾了2012年至2019年间8家医院从疑似感染关节中提取的滑膜液样本的报告。本研究共评估了179份膝关节抽吸关节液样本(80份培养阳性样本和99份培养阴性样本)。结果在对感染患者的80克样本进行的染色中,有60个真阳性,20个假阴性。相反,在无菌膝盖样本上进行的99次染色中,有99次真阴性,没有假阳性。检测膝关节假体周围感染的敏感性和特异性分别为75.0%和100.0%。此外,我们根据症状出现和抽吸之间的持续时间,将感染样本分为早期抽吸组(14天内)和晚期抽吸组(15天或更长时间)。第一组和第二组的革兰氏染色敏感性分别为84.2%和41.2%。结论在本研究中,术前吸出的关节液对感染并伴有短暂症状的人工膝关节周围关节的革兰氏染色显示出较高的敏感性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Radiological evaluation of coronal femoral and tibial morphology and coronal limb alignment in windswept deformity of the knee Lateral extra-articular procedures in anterior cruciate ligament reconstruction: Narrative review on current evidence Predictive symptoms associated with the development of radiographic knee osteoarthritis: a 10-year longitudinal study from the Iwaki cohort Achievement of minimal clinically important difference in shoulder function after reverse shoulder arthroplasty: a retrospective cohort study Classification of coronal plane alignment of arthritic and healthy knees in Japan
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1