Parametric optimization of hexavalent chromium removal by electrocoagulation technology with vertical rotating cylindrical aluminum electrodes using Taguchi and ANN model

IF 3 4区 环境科学与生态学 Q3 ENGINEERING, ENVIRONMENTAL Journal of Environmental Health Science and Engineering Pub Date : 2023-04-28 DOI:10.1007/s40201-023-00859-w
Amit Kumar, D. Basu
{"title":"Parametric optimization of hexavalent chromium removal by electrocoagulation technology with vertical rotating cylindrical aluminum electrodes using Taguchi and ANN model","authors":"Amit Kumar,&nbsp;D. Basu","doi":"10.1007/s40201-023-00859-w","DOIUrl":null,"url":null,"abstract":"<div><p>This study aims to evaluate the performance of rotating aluminum electrodes in the electrocoagulation reactor for removing hexavalent chromium (Cr<sup>6+)</sup> from synthetic tannery wastewater. Taguchi and Artificial Neural Network (ANN) based models were developed to obtain the optimum condition for maximum Cr<sup>6+</sup> removal. The optimum working condition obtained by Taguchi approach for the maximum Cr<sup>6+</sup> removal (94%) was: Initial Cr<sup>6+</sup> concentration (Cr<sup>6+</sup><sub>i</sub>) = 15 mg/L; Current Density (CD) = 14.25 mA/cm<sup>2</sup>; Intial pH = 5; Rotational Speed of Electrode (RSE) = 70 rpm. In contrast, the optimal condition for maximum Cr<sup>6+</sup> ions removal (98.83%) obtained from the BR-ANN model was: Cr<sup>6+</sup><sub>i</sub> = 15 mg/L; CD = 14.36 mA/cm<sup>2</sup>; pHi = 5.2; RSE = 73 rpm. Compared to the Taguchi model, the BR-ANN model outperformed in terms of providing higher Cr<sup>6+</sup> removal (+ 4.83%); reduced energy demand (-0.035 KWh/gm Cr<sup>6+</sup> remove); lower error function value (χ<sup>2</sup> = -7.9674 and RMSE = -3.5414); and highest R<sup>2</sup> value (0.9991). The data for the conditions 91,007 &lt; Re &lt; 227,517 and Sc = 102.834 were found to fit the equation for the initial Cr<sup>6+</sup> concentration of 15 mg/l; Sh = 3.143Re<sup>0.125</sup> Sc<sup>0.33</sup>. The Cr<sup>6+</sup> removal kinetics was best described by Pseudo 2<sup>nd</sup> Order model, as validated by high R<sup>2</sup> and lower error functions value. The SEM and XRF analysis confirmed that Cr<sup>6+</sup> was adsorbed and precipitated along with metal hydroxide sludge. The rotating electrode led to lower SEEC (10.25 kWh/m<sup>3</sup>), as well as maximum Cr<sup>6+</sup> removal (98.83%), compared to EC process with stationary electrodes.</p></div>","PeriodicalId":628,"journal":{"name":"Journal of Environmental Health Science and Engineering","volume":"21 1","pages":"255 - 275"},"PeriodicalIF":3.0000,"publicationDate":"2023-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s40201-023-00859-w.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Health Science and Engineering","FirstCategoryId":"93","ListUrlMain":"https://link.springer.com/article/10.1007/s40201-023-00859-w","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study aims to evaluate the performance of rotating aluminum electrodes in the electrocoagulation reactor for removing hexavalent chromium (Cr6+) from synthetic tannery wastewater. Taguchi and Artificial Neural Network (ANN) based models were developed to obtain the optimum condition for maximum Cr6+ removal. The optimum working condition obtained by Taguchi approach for the maximum Cr6+ removal (94%) was: Initial Cr6+ concentration (Cr6+i) = 15 mg/L; Current Density (CD) = 14.25 mA/cm2; Intial pH = 5; Rotational Speed of Electrode (RSE) = 70 rpm. In contrast, the optimal condition for maximum Cr6+ ions removal (98.83%) obtained from the BR-ANN model was: Cr6+i = 15 mg/L; CD = 14.36 mA/cm2; pHi = 5.2; RSE = 73 rpm. Compared to the Taguchi model, the BR-ANN model outperformed in terms of providing higher Cr6+ removal (+ 4.83%); reduced energy demand (-0.035 KWh/gm Cr6+ remove); lower error function value (χ2 = -7.9674 and RMSE = -3.5414); and highest R2 value (0.9991). The data for the conditions 91,007 < Re < 227,517 and Sc = 102.834 were found to fit the equation for the initial Cr6+ concentration of 15 mg/l; Sh = 3.143Re0.125 Sc0.33. The Cr6+ removal kinetics was best described by Pseudo 2nd Order model, as validated by high R2 and lower error functions value. The SEM and XRF analysis confirmed that Cr6+ was adsorbed and precipitated along with metal hydroxide sludge. The rotating electrode led to lower SEEC (10.25 kWh/m3), as well as maximum Cr6+ removal (98.83%), compared to EC process with stationary electrodes.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
垂直旋转圆柱形铝电极电絮凝去除六价铬的参数优化
本研究旨在评价电凝反应器中旋转铝电极去除合成革废水中六价铬(Cr6+)的性能。建立了基于Taguchi和人工神经网络(ANN)的模型,以获得最大去除Cr6+的最佳条件。田口法获得的最大Cr6+去除率(94%)的最佳工况为:初始Cr6+浓度(Cr6+i) = 15 mg/L;电流密度(CD) = 14.25 mA/cm2;初始pH = 5;电极转速(RSE) = 70 rpm。BR-ANN模型对Cr6+离子最大去除率(98.83%)的最佳条件为:Cr6+i = 15 mg/L;CD = 14.36 mA/cm2;pHi = 5.2;RSE = 73 rpm。与Taguchi模型相比,BR-ANN模型在提供更高的Cr6+去除率方面表现更好(+ 4.83%);降低能源需求(-0.035 KWh/gm Cr6+去除量);误差函数值较低(χ2 = -7.9674, RMSE = -3.5414);最高R2值为0.9991。发现条件91,007 < Re < 227,517和Sc = 102.834的数据符合Cr6+初始浓度为15 mg/l的方程;Sh = 3.143Re0.125 Sc0.33。伪二阶模型能很好地描述Cr6+的去除动力学,R2高,误差函数值小。SEM和XRF分析证实,Cr6+随金属氢氧化物污泥被吸附沉淀。与固定电极的EC工艺相比,旋转电极的SEEC (10.25 kWh/m3)较低,Cr6+去除率最高(98.83%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Environmental Health Science and Engineering
Journal of Environmental Health Science and Engineering ENGINEERING, ENVIRONMENTAL-ENVIRONMENTAL SCIENCES
CiteScore
7.50
自引率
2.90%
发文量
81
期刊介绍: Journal of Environmental Health Science & Engineering is a peer-reviewed journal presenting timely research on all aspects of environmental health science, engineering and management. A broad outline of the journal''s scope includes: -Water pollution and treatment -Wastewater treatment and reuse -Air control -Soil remediation -Noise and radiation control -Environmental biotechnology and nanotechnology -Food safety and hygiene
期刊最新文献
Association between particulate matter exposure and acute ischemic stroke admissions in less-polluted areas: a time-series study using a distributed lag nonlinear model Assessing health risks of polycyclic aromatic hydrocarbons (PAHs) in cooked fish using monte carlo simulation: a global review and meta-analysis Correction: Comprehensive systematic review and meta-analysis of microplastic prevalence and abundance in freshwater fish species: the effect of fish species habitat, feeding behavior, and Fulton’s condition factor Microplastic predictive modelling with the integration of Artificial Neural Networks and Hidden Markov Models (ANN-HMM) Polystyrene nanoplastics: optimized removal using magnetic nano-adsorbent and toxicity assessment in zebrafish embryos
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1