Variación de la impedancia eléctrica a lo largo de cinco años postimplantación y relación con el umbral de confort máximo (MCL) en adultos portadores de implante coclear

IF 0.9 Q3 OTORHINOLARYNGOLOGY Acta otorrinolaringologica espanola Pub Date : 2024-01-01 DOI:10.1016/j.otorri.2023.04.005
Clara Espina González , Antonio Morant Ventura , Ignacio Pla Gil , María Aragonés Redó , Tomás Pérez Carbonell , Jaime Marco Algarra
{"title":"Variación de la impedancia eléctrica a lo largo de cinco años postimplantación y relación con el umbral de confort máximo (MCL) en adultos portadores de implante coclear","authors":"Clara Espina González ,&nbsp;Antonio Morant Ventura ,&nbsp;Ignacio Pla Gil ,&nbsp;María Aragonés Redó ,&nbsp;Tomás Pérez Carbonell ,&nbsp;Jaime Marco Algarra","doi":"10.1016/j.otorri.2023.04.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults.</p></div><div><h3>Methods</h3><p>Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria.</p></div><div><h3>Results</h3><p>33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7 ± 14.6 years. “Stability” was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43 kohms. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6 qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year.</p></div><div><h3>Conclusions</h3><p>Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months.</p></div>","PeriodicalId":7019,"journal":{"name":"Acta otorrinolaringologica espanola","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta otorrinolaringologica espanola","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0001651923000651","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults.

Methods

Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria.

Results

33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7 ± 14.6 years. “Stability” was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43 kohms. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6 qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year.

Conclusions

Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
成年人工耳蜗植入者植入后五年内电阻抗的变化及其与最大舒适阈 (MCL) 的关系
导言:人工耳蜗术后数月内,最大舒适度(MCL)、阈值水平(THR)和电阻抗会发生变化,直至稳定。本文旨在确定单侧植入人工耳蜗的成人患者在术后 5 年中阻抗的变化情况及其与 MCL 的关系。结果男性 33 人(42.3%),女性 45 人(57.7%),平均年龄(52.7±14.6)岁。"稳定 "是指随访时间与下一次随访时间之间没有统计学意义上的显著差异。内侧电极阻抗的变化在 3 个月时不再具有统计学意义,顶端电极阻抗的变化在 6 个月时不再具有统计学意义,其平均值分别为 5.84 和 6.43 千欧。基底和心尖电极的 MCL 在 2 年后趋于稳定,内侧电极的 MCL 在 3 年后趋于稳定,平均值分别为 24.9、22.7 和 25.6qu。中等电极的 MCL 与阻抗之间存在相关性,最长可达 3 个月,心尖电极的 MCL 与阻抗之间存在相关性,最长可达 1 年。MCL 在两年内明显增加。阻抗与 MCL 的关系持续到 6 个月。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.40
自引率
20.00%
发文量
44
审稿时长
44 days
期刊介绍: Es la revista más importante en español dedicada a la especialidad. Ofrece progresos científicos y técnicos tanto a nivel de originales como de casos clínicos. Además, es la Publicación Oficial de la Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial y está presente en los más prestigiosos índices de referencia.
期刊最新文献
Retrolabyrinthine approach to the lateral skull base: The value of preoperative temporal bone CT analysis Situación actual de la tutoría en la formación especializada en otorrinolaringología en España. ¿Dónde estamos? ¿Hacia dónde queremos ir? Prevalencia de apnea obstructiva del sueño en pacientes obesos candidatos a cirugía bariátrica y cuestionarios predictores Recurrent peritonsillar abscess in adults: Incidence and risk factors in a prospective longitudinal cohort Enhancing the coverage and rotation of anterior ethmoidal artery flap for septal perforation closure: Insights from a flap design study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1