Analysis of the degradation of amorphous silicon mini-modules under a severe sequential UV/DH test

IF 1.9 Q3 PHYSICS, APPLIED EPJ Photovoltaics Pub Date : 2023-01-01 DOI:10.1051/epjpv/2023014
Julia Vincent, Venkata Ramana Posa, Ali Khouzam, P. Logerais, Mustapha El Yaakoubi, A. Labouret
{"title":"Analysis of the degradation of amorphous silicon mini-modules under a severe sequential UV/DH test","authors":"Julia Vincent, Venkata Ramana Posa, Ali Khouzam, P. Logerais, Mustapha El Yaakoubi, A. Labouret","doi":"10.1051/epjpv/2023014","DOIUrl":null,"url":null,"abstract":"This study presents the results of severe accelerated tests carried out on four encapsulated amorphous silicon (a-Si) mini-modules. All the a-Si mini-modules were exposed to a 85 °C and 85% relative humidity damp heat (DH) prolonged treatment for 5000 h representing five times the duration specified by the IEC 61215 standard for qualification tests. For two of the four mini-modules, the DH test was preceded by a severe UV preconditioning, by applying 30 times the dose of 15 kWh/m2 at a temperature of 50 °C as prescribed by the IEC 61215 standard, in order to enhance the degradation during the following DH test and to reduce the overall testing time. I–V curves were plotted with a time step of 100 h under standard test conditions (STC) using a class A solar simulator and a source meter in order to monitor the degradation throughout both the tests. A visual inspection with photographic capturing was also performed at each stage to detect the apparent defects. Corrosion observed after 2000 h owing to the ingress of humidity is explained here by two possible infiltration paths in the layers of the mini-modules. Delamination occurred after 5000 h for the PV mini-modules which underwent the extended DH test. After 5000 h of damp heat testing, the degradation of the maximal power (Pmax) was found to be slightly accelerated for the a-Si mini-modules that were previously exposed to a severe UV preconditioning, with a value reaching 80% of its initial value, whereas, for the others only subjected to the prolonged DH test, the maximal power remained above 80% of its initial value. In all cases, the mini-modules seemed highly reliable with no failure after 5000 h of accelerated testing, and, based on an equivalent time of 20 years for 1000 h of accelerated test, they would exhibit a limited degradation rate of 0.2%/year in outdoor field conditions.","PeriodicalId":42768,"journal":{"name":"EPJ Photovoltaics","volume":"1 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EPJ Photovoltaics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/epjpv/2023014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents the results of severe accelerated tests carried out on four encapsulated amorphous silicon (a-Si) mini-modules. All the a-Si mini-modules were exposed to a 85 °C and 85% relative humidity damp heat (DH) prolonged treatment for 5000 h representing five times the duration specified by the IEC 61215 standard for qualification tests. For two of the four mini-modules, the DH test was preceded by a severe UV preconditioning, by applying 30 times the dose of 15 kWh/m2 at a temperature of 50 °C as prescribed by the IEC 61215 standard, in order to enhance the degradation during the following DH test and to reduce the overall testing time. I–V curves were plotted with a time step of 100 h under standard test conditions (STC) using a class A solar simulator and a source meter in order to monitor the degradation throughout both the tests. A visual inspection with photographic capturing was also performed at each stage to detect the apparent defects. Corrosion observed after 2000 h owing to the ingress of humidity is explained here by two possible infiltration paths in the layers of the mini-modules. Delamination occurred after 5000 h for the PV mini-modules which underwent the extended DH test. After 5000 h of damp heat testing, the degradation of the maximal power (Pmax) was found to be slightly accelerated for the a-Si mini-modules that were previously exposed to a severe UV preconditioning, with a value reaching 80% of its initial value, whereas, for the others only subjected to the prolonged DH test, the maximal power remained above 80% of its initial value. In all cases, the mini-modules seemed highly reliable with no failure after 5000 h of accelerated testing, and, based on an equivalent time of 20 years for 1000 h of accelerated test, they would exhibit a limited degradation rate of 0.2%/year in outdoor field conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非晶硅微型组件在严格的连续UV/DH测试下的降解分析
本研究介绍了在四个封装的非晶硅(a-Si)微型模块上进行的严重加速测试的结果。所有a- si微型模块暴露在85°C和85%相对湿度的湿热(DH)下,长时间处理5000小时,是IEC 61215标准规定的合格测试时间的五倍。对于四个迷你模块中的两个,在进行DH测试之前进行了严格的紫外线预处理,按照IEC 61215标准的规定,在50°C的温度下施加30倍于15 kWh/m2的剂量,以便在接下来的DH测试中增强降解并减少总体测试时间。在标准测试条件(STC)下,使用a类太阳模拟器和源计绘制时间步长为100 h的I-V曲线,以便监测整个测试过程中的退化情况。在每个阶段还进行了摄影捕捉的视觉检查,以检测明显的缺陷。在2000 h后观察到的由于湿度进入的腐蚀,这里用微型模块层中的两种可能的渗透路径来解释。经过扩展DH测试的PV微型组件在5000 h后发生分层。经过5000 h的湿热测试,发现先前暴露于严重紫外线预处理的a- si微型模块的最大功率(Pmax)的退化略有加速,达到其初始值的80%,而对于其他仅经过长时间DH测试的a- si微型模块,最大功率仍保持在其初始值的80%以上。在所有情况下,迷你模块在5000小时的加速测试后似乎高度可靠,没有出现故障,并且,基于20年的等效时间,1000小时的加速测试,它们在室外现场条件下将表现出0.2%/年的有限降解率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
EPJ Photovoltaics
EPJ Photovoltaics PHYSICS, APPLIED-
CiteScore
2.30
自引率
4.00%
发文量
15
审稿时长
8 weeks
期刊最新文献
Epitaxy and characterization of InP/InGaAs tandem solar cells grown by MOVPE on InP and Si substrates Effect of the cooling rate on encapsulant's crystallinity and optical properties, and photovoltaic modules' lifetime Insights into circular material and waste flows from c-Si PV industry A direct measure of positive feedback loop-gain due to reverse bias damage in thin-film solar cells using lock-in thermography Combining circularity and environmental metrics to assess material flows of PV silicon
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1