Design and implementation of anulus-shaped ciliary structure for four-unit MEMS vector hydrophone

Xiaoyong Zhang, Nixin Shen, Qingda Xu, Yu Pei, Yuqi Lian, Weidong Wang, Zhang Guojun, Zhang Wendong
{"title":"Design and implementation of anulus-shaped ciliary structure for four-unit MEMS vector hydrophone","authors":"Xiaoyong Zhang, Nixin Shen, Qingda Xu, Yu Pei, Yuqi Lian, Weidong Wang, Zhang Guojun, Zhang Wendong","doi":"10.1051/IJMQE/2021002","DOIUrl":null,"url":null,"abstract":"Inspired from fish bionics, an anulus-shaped ciliary structure for four-unit MEMS vector hydrophone (AFUVH) is proposed in this paper. It replaces the previous bionic cilium-shaped structure and becomes a novel sensing structure in the four-unit MEMS vector hydrophone (FUVH), which realizes the complete simulation of the fish lateral line neuromasts structurally and functionally. It not only improves the sensitivity of FUVH, but also retains a sufficient bandwidth, which improves the overall performance of FUVH for monitoring remote ships noise. Meanwhile, this paper theoretically analyzes the performance of AFUVH for detecting acoustic signals. ANSYS 17.0 simulation is used to derive the parameters of effective structure and optimum dimension structure of annulus-shaped ciliary structure. Finally, the experimental results show that comparing with cilium-structured FUVH, the sensitivity of AFUVH with effective structure is increased by 3.92 dB, and the sensitivity of AFUVH with optimum dimension structure is increased by 5.87 dB, reaching up to −177.53 dB.","PeriodicalId":38371,"journal":{"name":"International Journal of Metrology and Quality Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Metrology and Quality Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/IJMQE/2021002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 2

Abstract

Inspired from fish bionics, an anulus-shaped ciliary structure for four-unit MEMS vector hydrophone (AFUVH) is proposed in this paper. It replaces the previous bionic cilium-shaped structure and becomes a novel sensing structure in the four-unit MEMS vector hydrophone (FUVH), which realizes the complete simulation of the fish lateral line neuromasts structurally and functionally. It not only improves the sensitivity of FUVH, but also retains a sufficient bandwidth, which improves the overall performance of FUVH for monitoring remote ships noise. Meanwhile, this paper theoretically analyzes the performance of AFUVH for detecting acoustic signals. ANSYS 17.0 simulation is used to derive the parameters of effective structure and optimum dimension structure of annulus-shaped ciliary structure. Finally, the experimental results show that comparing with cilium-structured FUVH, the sensitivity of AFUVH with effective structure is increased by 3.92 dB, and the sensitivity of AFUVH with optimum dimension structure is increased by 5.87 dB, reaching up to −177.53 dB.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
四单元MEMS矢量水听器环状纤毛结构的设计与实现
从鱼类仿生学的角度出发,提出了一种四单元MEMS矢量水听器(AFUVH)的环状纤毛结构。它取代了以前的仿生纤毛状结构,成为四单元MEMS矢量水听器(FUVH)中的一种新型传感结构,在结构和功能上完全模拟了鱼类侧线神经杆。它不仅提高了FUVH的灵敏度,而且保留了足够的带宽,提高了FUVH监测远程船舶噪声的整体性能。同时,从理论上分析了AFUVH探测声信号的性能。利用ANSYS 17.0仿真,推导出环形纤毛结构的有效结构参数和最佳尺寸结构参数。实验结果表明,与纤毛结构的FUVH相比,有效结构的灵敏度提高了3.92 dB,最佳尺寸结构的灵敏度提高了5.87 dB,达到- 177.53 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Metrology and Quality Engineering
International Journal of Metrology and Quality Engineering Engineering-Safety, Risk, Reliability and Quality
CiteScore
1.70
自引率
0.00%
发文量
8
审稿时长
8 weeks
期刊最新文献
Investigation of influence of grinding wheel and cutting parameters on surface roughness and surface hardening when relieving grinding the gear milling teeth surface based on the Archimedes' spiral Analysis and treatment of current unbalance abnormal situation of 750 kV double-circuit parallel transmission line Characterizing a linear pyrometer at the National Metrology Institute of South Africa Estimation of parallelism measurement uncertainty according to the Geometrical Product Specifications standard using coordinate measuring machine First study on harvesting electromagnetic noise energy generated by the frequency converters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1