{"title":"Frequency of use and activation of safety-engineered sharps devices: a sharps container audit in five Australian capital cities","authors":"Terry Grimmond FASM, BAgrSc, GrDpAdEd","doi":"10.1071/HI14009","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Sharps injuries (SI) among healthcare personnel (HCP) in Australia are of such concern the matter was brought before Parliament in 2013. Many SI from safety-engineered devices (SED) are due to nonactivation. Monitoring of activation is recommended. This paper outlines a sharps container (SC) contents audit conducted in Australian capital cities.</p></div><div><h3>Methods</h3><p>Reusable, 22 L SC (Sharpsmart, Daniels Corporation, Melbourne) were randomly selected from random healthcare facilities (HCF) in five cities. Wearing protective apparel, the operator opened and decanted SC and sorted hollow-bore needles (HBN) into: capped <em>v.</em> uncapped non-SED, and activated or non-fully activated SED. Volumes and weights were recorded for inter-study comparisons. WinPepi v2.78 was used to calculate probability (significance set at ≤ 0.05), relative-risk and 95% confidence limits.</p></div><div><h3>Results</h3><p>1212 L of sharps (167.9 kg) from 102 SC from 27 hospitals were audited. Many devices were bloodcontaminated. Of the 9651 HBN, 30.4% were SED and 19.4% of the SED were not, or partially, activated. Of the 6718 non-SED, 30.6% were capped needles or capped needle-syringes. City averages for capped or naked sharps ranged from 64.2% (Sydney) to 97.8% (Adelaide) while hospital averages ranged from 32.6 to 100%. Overall, 54.2% of devices were discarded ‘sharp’.</p></div><div><h3>Conclusions</h3><p>It is disturbing that 75.5% of hollow-bore needles were capped or naked, indicating a high proportion of Australian HCP are unnecessarily at risk of SI while handling sharps. The high non-use of SED and non-activation of SED needs researching.Widespread SED evaluation and adoption (automatic and semi-automatic SED where feasible), repetitive competency training and safety-ownership are needed. Legislation may be indicated.</p></div>","PeriodicalId":90514,"journal":{"name":"Healthcare infection","volume":"19 3","pages":"Pages 95-100"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1071/HI14009","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Healthcare infection","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1835561716300369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Introduction
Sharps injuries (SI) among healthcare personnel (HCP) in Australia are of such concern the matter was brought before Parliament in 2013. Many SI from safety-engineered devices (SED) are due to nonactivation. Monitoring of activation is recommended. This paper outlines a sharps container (SC) contents audit conducted in Australian capital cities.
Methods
Reusable, 22 L SC (Sharpsmart, Daniels Corporation, Melbourne) were randomly selected from random healthcare facilities (HCF) in five cities. Wearing protective apparel, the operator opened and decanted SC and sorted hollow-bore needles (HBN) into: capped v. uncapped non-SED, and activated or non-fully activated SED. Volumes and weights were recorded for inter-study comparisons. WinPepi v2.78 was used to calculate probability (significance set at ≤ 0.05), relative-risk and 95% confidence limits.
Results
1212 L of sharps (167.9 kg) from 102 SC from 27 hospitals were audited. Many devices were bloodcontaminated. Of the 9651 HBN, 30.4% were SED and 19.4% of the SED were not, or partially, activated. Of the 6718 non-SED, 30.6% were capped needles or capped needle-syringes. City averages for capped or naked sharps ranged from 64.2% (Sydney) to 97.8% (Adelaide) while hospital averages ranged from 32.6 to 100%. Overall, 54.2% of devices were discarded ‘sharp’.
Conclusions
It is disturbing that 75.5% of hollow-bore needles were capped or naked, indicating a high proportion of Australian HCP are unnecessarily at risk of SI while handling sharps. The high non-use of SED and non-activation of SED needs researching.Widespread SED evaluation and adoption (automatic and semi-automatic SED where feasible), repetitive competency training and safety-ownership are needed. Legislation may be indicated.