Yang Hong , Jie Wang , Xiafen Zhang , Dan Zhao , Hanliang He , Mengting Sun
{"title":"The effectiveness of home rehabilitation based on BPMpathway exercise rehabilitation system for patients after total knee arthroplasty in China","authors":"Yang Hong , Jie Wang , Xiafen Zhang , Dan Zhao , Hanliang He , Mengting Sun","doi":"10.1016/j.ijotn.2023.101062","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>There is significant interest in the use of web-based technologies for rehabilitation of patients after total knee arthroplasty (TKA). BPMpathway is a combination of a wireless BPMpro sensor and mobile app to provide a personalized post-operative support programme for TKA patients.</p></div><div><h3>Objective</h3><p>To investigate the impact of the BPMpathway exercise rehabilitation system on home rehabilitation for TKA patients.</p></div><div><h3>Methods</h3><p>This study had a quasi-experimental design and was conducted with 42 inpatients after TKA. Patients were divided into a control group (n = 21) and an intervention group (n = 21) according to sequence of hospitalization. After discharge, patients in the control group received routine follow-up outside the hospital, while the intervention group, underwent out-of-hospital transitional care utilizing the BPMpathway exercise rehabilitation system. Knee function scores (HSS), quality of life scores (SF-36), and functional exercise compliance scores were compared between the two groups at 1, 3, and 6 months after TKA.</p></div><div><h3>Results</h3><p>The between-group differences in knee function were statistically significant at 1, 3, and 6 months post-operation (t = 6.299, 10.021, 13.064, all P < 0.05). There were between-group significant differences observed in functional exercise compliance and quality of life at 1 and 3 months (t = 7.166, 2.435, both P < 0.05; t = 2.879, 3.117, both P < 0.05). However, there were no significant differences at 6 months in these two respects (t = 0.167, 0.901, both P > 0.05).</p></div><div><h3>Conclusions</h3><p>The BPMpathway exercise rehabilitation system seems to be potential effective in improving knee function, early compliance with functional exercise and quality of life in TKA patients.</p></div>","PeriodicalId":45099,"journal":{"name":"International Journal of Orthopaedic and Trauma Nursing","volume":"53 ","pages":"Article 101062"},"PeriodicalIF":1.5000,"publicationDate":"2023-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Orthopaedic and Trauma Nursing","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1878124123000667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0
Abstract
Background
There is significant interest in the use of web-based technologies for rehabilitation of patients after total knee arthroplasty (TKA). BPMpathway is a combination of a wireless BPMpro sensor and mobile app to provide a personalized post-operative support programme for TKA patients.
Objective
To investigate the impact of the BPMpathway exercise rehabilitation system on home rehabilitation for TKA patients.
Methods
This study had a quasi-experimental design and was conducted with 42 inpatients after TKA. Patients were divided into a control group (n = 21) and an intervention group (n = 21) according to sequence of hospitalization. After discharge, patients in the control group received routine follow-up outside the hospital, while the intervention group, underwent out-of-hospital transitional care utilizing the BPMpathway exercise rehabilitation system. Knee function scores (HSS), quality of life scores (SF-36), and functional exercise compliance scores were compared between the two groups at 1, 3, and 6 months after TKA.
Results
The between-group differences in knee function were statistically significant at 1, 3, and 6 months post-operation (t = 6.299, 10.021, 13.064, all P < 0.05). There were between-group significant differences observed in functional exercise compliance and quality of life at 1 and 3 months (t = 7.166, 2.435, both P < 0.05; t = 2.879, 3.117, both P < 0.05). However, there were no significant differences at 6 months in these two respects (t = 0.167, 0.901, both P > 0.05).
Conclusions
The BPMpathway exercise rehabilitation system seems to be potential effective in improving knee function, early compliance with functional exercise and quality of life in TKA patients.